-
1
-
-
0021716134
-
Computer-assisted corneal topography: High-resolution graphic presentation and analysis of keratoscopy
-
Klyce S.D. Computer-assisted corneal topography high-resolution graphic presentation and analysis of keratoscopy. Invest Ophthalmol Vis Sci. 25:1984;1426-1435.
-
(1984)
Invest Ophthalmol Vis Sci
, vol.25
, pp. 1426-1435
-
-
Klyce, S.D.1
-
3
-
-
0023106475
-
Graphic presentation of computer-analyzed keratoscope photographs
-
Maguire L.J., Singer D.E., Klyce S.D. Graphic presentation of computer-analyzed keratoscope photographs. Arch Ophthalmol. 105:1987;223-230.
-
(1987)
Arch Ophthalmol
, vol.105
, pp. 223-230
-
-
Maguire, L.J.1
Singer, D.E.2
Klyce, S.D.3
-
4
-
-
0028788315
-
Corneal topography and irregular astigmatism
-
Raasch T.W. Corneal topography and irregular astigmatism. Optom Vis Sci. 72:1995;809-815.
-
(1995)
Optom Vis Sci
, vol.72
, pp. 809-815
-
-
Raasch, T.W.1
-
5
-
-
0029010154
-
Fourier analysis of video-keratographic data: A tool for separation of spherical, regular astigmatic and irregular astigmatic corneal power components
-
Hjortdal J.Ø, Erdmann L., Bek T. Fourier analysis of video-keratographic data a tool for separation of spherical, regular astigmatic and irregular astigmatic corneal power components. Ophthalmic Physiol Opt. 15:1995;171-185.
-
(1995)
Ophthalmic Physiol Opt
, vol.15
, pp. 171-185
-
-
Hjortdal J.Ø1
Erdmann, L.2
Bek, T.3
-
6
-
-
0029936406
-
Evaluating surgically induced astigmatism by Fourier analysis of corneal topography data
-
Olsen T., Dam-Johansen M., Bek T., Hjortdal J.Ø. Evaluating surgically induced astigmatism by Fourier analysis of corneal topography data. J Cataract Refract Surg. 22:1996;318-323.
-
(1996)
J Cataract Refract Surg
, vol.22
, pp. 318-323
-
-
Olsen, T.1
Dam-Johansen, M.2
Bek, T.3
Hjortdal J.Ø4
-
7
-
-
0031978587
-
Quantitative evaluation of irregular astigmatism by Fourier series harmonic analysis of videokeratography data
-
Oshika T., Tomidokoro A., Maruo K., et al. Quantitative evaluation of irregular astigmatism by Fourier series harmonic analysis of videokeratography data. Invest Ophthalmol Vis Sci. 39:1998;705-709.
-
(1998)
Invest Ophthalmol Vis Sci
, vol.39
, pp. 705-709
-
-
Oshika, T.1
Tomidokoro, A.2
Maruo, K.3
-
8
-
-
0031794468
-
Fourier analysis of corneal topography data after photorefractive keratectomy
-
Keller P.R., McGhee C.N., Weed K.H. Fourier analysis of corneal topography data after photorefractive keratectomy. J Cataract Refract Surg. 24:1998;1447-1455.
-
(1998)
J Cataract Refract Surg
, vol.24
, pp. 1447-1455
-
-
Keller, P.R.1
McGhee, C.N.2
Weed, K.H.3
-
9
-
-
0036157721
-
Progression of keratoconus assessed by Fourier analysis of videokeratography data
-
Oshika T., Tanabe T., Tomidokoro A., Amano S. Progression of keratoconus assessed by Fourier analysis of videokeratography data. Ophthalmology. 109:2002;339-342.
-
(2002)
Ophthalmology
, vol.109
, pp. 339-342
-
-
Oshika, T.1
Tanabe, T.2
Tomidokoro, A.3
Amano, S.4
-
10
-
-
0033756625
-
Changes in anterior and posterior corneal curvatures in keratoconus
-
Tomidokoro A., Oshika T., Amano S., et al. Changes in anterior and posterior corneal curvatures in keratoconus. Ophthalmology. 107:2000;1328-1332.
-
(2000)
Ophthalmology
, vol.107
, pp. 1328-1332
-
-
Tomidokoro, A.1
Oshika, T.2
Amano, S.3
-
11
-
-
0033017191
-
Quantitative analysis of regular and irregular astigmatism induced by pterygium
-
Tomidokoro A., Oshika T., Amano S., et al. Quantitative analysis of regular and irregular astigmatism induced by pterygium. Cornea. 18:1999;412-415.
-
(1999)
Cornea
, vol.18
, pp. 412-415
-
-
Tomidokoro, A.1
Oshika, T.2
Amano, S.3
-
12
-
-
0035190145
-
Corneal irregular astigmatism and contrast sensitivity after photorefractive keratectomy
-
Tomidokoro A., Soya K., Miyata K., et al. Corneal irregular astigmatism and contrast sensitivity after photorefractive keratectomy. Ophthalmology. 108:2001;2209-2212.
-
(2001)
Ophthalmology
, vol.108
, pp. 2209-2212
-
-
Tomidokoro, A.1
Soya, K.2
Miyata, K.3
-
13
-
-
0035046260
-
Corneal irregular astigmatism after laser in situ keratomileusis for myopia
-
Baek T.M., Lee K.H., Tomidokoro A., Oshika T. Corneal irregular astigmatism after laser in situ keratomileusis for myopia. Br J Ophthalmol. 85:2001;534-536.
-
(2001)
Br J Ophthalmol
, vol.85
, pp. 534-536
-
-
Baek, T.M.1
Lee, K.H.2
Tomidokoro, A.3
Oshika, T.4
-
14
-
-
0030909171
-
Corneal versus scleral tunnel incision in cataract surgery: A randomized study
-
Olsen T., Dam-Johansen M., Bek T., Hjortdal J.Ø. Corneal versus scleral tunnel incision in cataract surgery a randomized study. J Cataract Refract Surg. 23:1997;337-341.
-
(1997)
J Cataract Refract Surg
, vol.23
, pp. 337-341
-
-
Olsen, T.1
Dam-Johansen, M.2
Bek, T.3
Hjortdal J.Ø4
-
15
-
-
0033772861
-
Fourier analysis of irregular astigmatism after implantation of 3 types of intraocular lenses
-
Hayashi K., Hayashi H., Oshika T., Hayashi F. Fourier analysis of irregular astigmatism after implantation of 3 types of intraocular lenses. J Cataract Refract Surg. 26:2000;1510-1516.
-
(2000)
J Cataract Refract Surg
, vol.26
, pp. 1510-1516
-
-
Hayashi, K.1
Hayashi, H.2
Oshika, T.3
Hayashi, F.4
-
16
-
-
0033757697
-
Regular and irregular astigmatism after superior versus temporal scleral incision cataract surgery
-
Oshika T., Sugita G., Tanabe T., et al. Regular and irregular astigmatism after superior versus temporal scleral incision cataract surgery. Ophthalmology. 107:2000;2049-2053.
-
(2000)
Ophthalmology
, vol.107
, pp. 2049-2053
-
-
Oshika, T.1
Sugita, G.2
Tanabe, T.3
-
17
-
-
0036196958
-
Fourier series harmonic analysis of corneal topography following suture removal after penetrating keratoplasty
-
Kagaya F., Tomidokoro T., Tanaka S., et al. Fourier series harmonic analysis of corneal topography following suture removal after penetrating keratoplasty. Cornea. 21:2002;256-259.
-
(2002)
Cornea
, vol.21
, pp. 256-259
-
-
Kagaya, F.1
Tomidokoro, T.2
Tanaka, S.3
-
19
-
-
0031692782
-
Corneal astigmatism after scleral buckling surgery assessed by Fourier analysis of videokeratography data
-
Tomidokoro A., Oshika T., Kojima T. Corneal astigmatism after scleral buckling surgery assessed by Fourier analysis of videokeratography data. Cornea. 17:1998;517-521.
-
(1998)
Cornea
, vol.17
, pp. 517-521
-
-
Tomidokoro, A.1
Oshika, T.2
Kojima, T.3
-
20
-
-
0001773864
-
Ectatic corneal degenerations
-
H.E. Kaufman, B.A. Barron, & M.B. McDonald. Boston: Butterworth-Heinemann
-
Maguire L.J. Ectatic corneal degenerations. Kaufman H.E., Barron B.A., McDonald M.B. The Cornea. 2nd ed:1998;525-550 Butterworth-Heinemann, Boston.
-
(1998)
The Cornea 2nd Ed
, pp. 525-550
-
-
Maguire, L.J.1
-
21
-
-
0021343891
-
Keratoconus and related noninflammatory corneal thinning disorders
-
Krachmer J.H., Feder R.S., Belin M.W. Keratoconus and related noninflammatory corneal thinning disorders. Surv Ophthalmol. 28:1984;293-322.
-
(1984)
Surv Ophthalmol
, vol.28
, pp. 293-322
-
-
Krachmer, J.H.1
Feder, R.S.2
Belin, M.W.3
-
22
-
-
0024348302
-
Corneal topography of early keratoconus
-
Maguire L.J., Bourne W.M. Corneal topography of early keratoconus. Am J Ophthalmol. 108:1989;107-112.
-
(1989)
Am J Ophthalmol
, vol.108
, pp. 107-112
-
-
Maguire, L.J.1
Bourne, W.M.2
-
23
-
-
0027389210
-
Videokeratography of the fellow eye in unilateral keratoconus
-
Rabinowitz Y.S., Nesburn A.B., McDonnell P.J. Videokeratography of the fellow eye in unilateral keratoconus. Ophthalmology. 100:1993;181-186.
-
(1993)
Ophthalmology
, vol.100
, pp. 181-186
-
-
Rabinowitz, Y.S.1
Nesburn, A.B.2
McDonnell, P.J.3
-
24
-
-
0025363515
-
Computer-assisted corneal topography in family members of patients with keratoconus
-
Rabinowitz Y.S., Garbus J., McDonnell P.J. Computer-assisted corneal topography in family members of patients with keratoconus. Arch Ophthalmol. 108:1990;365-371.
-
(1990)
Arch Ophthalmol
, vol.108
, pp. 365-371
-
-
Rabinowitz, Y.S.1
Garbus, J.2
McDonnell, P.J.3
-
25
-
-
0028885963
-
Comparison of methods for detecting keratoconus using videokeratography
-
Maeda N., Klyce S.D., Smolek M.K. Comparison of methods for detecting keratoconus using videokeratography. Arch Ophthalmol. 113:1995;870-874.
-
(1995)
Arch Ophthalmol
, vol.113
, pp. 870-874
-
-
Maeda, N.1
Klyce, S.D.2
Smolek, M.K.3
-
26
-
-
0032128397
-
Detection and classification of mild irregular astigmatism in patients with good visual acuity
-
Maeda N., Klyce S.D., Tano Y. Detection and classification of mild irregular astigmatism in patients with good visual acuity. Surv Ophthalmol. 43:1998;53-58.
-
(1998)
Surv Ophthalmol
, vol.43
, pp. 53-58
-
-
Maeda, N.1
Klyce, S.D.2
Tano, Y.3
-
27
-
-
0030757559
-
Current keratoconus detection methods compared with a neural network approach
-
Smolek M.K., Klyce S.D. Current keratoconus detection methods compared with a neural network approach. Invest Ophthalmol Vis Sci. 38:1997;2290-2299.
-
(1997)
Invest Ophthalmol Vis Sci
, vol.38
, pp. 2290-2299
-
-
Smolek, M.K.1
Klyce, S.D.2
-
28
-
-
0025803917
-
Mean and range of the ambulatory pressure in normotensive subjects from a meta-analysis of 23 studies
-
Staessen J.A., Fagard R.H., Lijnen P.J., et al. Mean and range of the ambulatory pressure in normotensive subjects from a meta-analysis of 23 studies. Am J Cardiol. 67:1991;723-727.
-
(1991)
Am J Cardiol
, vol.67
, pp. 723-727
-
-
Staessen, J.A.1
Fagard, R.H.2
Lijnen, P.J.3
-
29
-
-
0026847003
-
Mean and range of the ambulatory pressure in normotensive subjects
-
Staessen J., Guo C., De Cort P., et al. Mean and range of the ambulatory pressure in normotensive subjects. Chin Med J (Engl). 105:1992;328-333.
-
(1992)
Chin Med J (Engl)
, vol.105
, pp. 328-333
-
-
Staessen, J.1
Guo, C.2
De Cort, P.3
-
30
-
-
0008091942
-
Computerized corneal topography in keratoconus
-
L. Buratto. Thorofare, NJ: Slack Inc
-
Genisi C. Computerized corneal topography in keratoconus. Buratto L. Corneal Topography. The Clinical Atlas. 1996;95-133 Slack Inc, Thorofare, NJ.
-
(1996)
Corneal Topography. the Clinical Atlas
, pp. 95-133
-
-
Genisi, C.1
-
31
-
-
0002313399
-
Noninflammatory ectatic disorders
-
J.H. Krachmer, M.J. Mannis, & E.J. Holland. St. Louis, Mo: Mosby
-
Feder R.S. Noninflammatory ectatic disorders. Krachmer J.H., Mannis M.J., Holland E.J. Cornea. Vol. 2. 1997;1091-1106 Mosby, St. Louis, Mo.
-
(1997)
Cornea. Vol. 2
, pp. 1091-1106
-
-
Feder, R.S.1
-
33
-
-
0028116640
-
Excimer laser in situ keratomileusis and photorefractive keratectomy for correction of high myopia
-
Pallikaris I.G., Siganos D.S. Excimer laser in situ keratomileusis and photorefractive keratectomy for correction of high myopia. J Refract Corneal Surg. 10:1994;498-510.
-
(1994)
J Refract Corneal Surg
, vol.10
, pp. 498-510
-
-
Pallikaris, I.G.1
Siganos, D.S.2
-
34
-
-
0030911075
-
Topographical analysis of ablation centration after excimer laser photorefractive keratectomy and laser in situ keratomileusis for high myopia
-
Mulhern M.G., Foley-Nolan A., O'Keefe M., Condon P.I. Topographical analysis of ablation centration after excimer laser photorefractive keratectomy and laser in situ keratomileusis for high myopia. J Cataract Refract Surg. 23:1997;488-494.
-
(1997)
J Cataract Refract Surg
, vol.23
, pp. 488-494
-
-
Mulhern, M.G.1
Foley-Nolan, A.2
O'Keefe, M.3
Condon, P.I.4
-
35
-
-
0030901504
-
Corneal topography after selective suture removal for astigmatism following keratoplasty
-
Goren M.B., Dana M.R., Rapuano C.J., et al. Corneal topography after selective suture removal for astigmatism following keratoplasty. Ophthalmic Surg Lasers. 28:1997;208-214.
-
(1997)
Ophthalmic Surg Lasers
, vol.28
, pp. 208-214
-
-
Goren, M.B.1
Dana, M.R.2
Rapuano, C.J.3
-
36
-
-
0032936566
-
Proposed classification for topographic patterns seen after penetrating keratoplasty
-
Karabatsas C.H., Cook S.D., Sparrow J.M. Proposed classification for topographic patterns seen after penetrating keratoplasty. Br J Ophthalmol. 83:1999;403-409.
-
(1999)
Br J Ophthalmol
, vol.83
, pp. 403-409
-
-
Karabatsas, C.H.1
Cook, S.D.2
Sparrow, J.M.3
|