메뉴 건너뛰기




Volumn 91, Issue 3, 2004, Pages 234-240

The influence of implant location and length on stress distribution for three-unit implant-supported posterior cantilever fixed partial dentures

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CORTICAL BONE; DENTURE; FORCE; MANDIBLE; MATHEMATICAL MODEL; MECHANICAL STRESS; PERIODONTAL DISEASE; PREMOLAR TOOTH; TOOTH IMPLANTATION;

EID: 1842475453     PISSN: 00223913     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.prosdent.2003.12.017     Document Type: Article
Times cited : (85)

References (22)
  • 1
    • 0027567458 scopus 로고
    • The longitudinal clinical effectiveness of osseointegrated dental implants in posterior partially edentulous patients
    • Zarb G.A., Schmitt A. The longitudinal clinical effectiveness of osseointegrated dental implants in posterior partially edentulous patients. Int J Prosthodont. 6:1993;189-196.
    • (1993) Int J Prosthodont , vol.6 , pp. 189-196
    • Zarb, G.A.1    Schmitt, A.2
  • 2
    • 0035513723 scopus 로고    scopus 로고
    • Patient evaluation of treatment with fixed implant-supported partial dentures
    • Yi S.W., Carlsson G.E., Ericsson I., Kim C.K. Patient evaluation of treatment with fixed implant-supported partial dentures. J Oral Rehabil. 28:2001;998-1002.
    • (2001) J Oral Rehabil , vol.28 , pp. 998-1002
    • Yi, S.W.1    Carlsson, G.E.2    Ericsson, I.3    Kim, C.K.4
  • 3
    • 0038488558 scopus 로고    scopus 로고
    • Implant-supported fixed partial prostheses: A retrospective study
    • Johansson L.A., Ekfeldt A. Implant-supported fixed partial prostheses: a retrospective study. Int J Prosthodont. 16:2003;172-176.
    • (2003) Int J Prosthodont , vol.16 , pp. 172-176
    • Johansson, L.A.1    Ekfeldt, A.2
  • 4
    • 0032082983 scopus 로고    scopus 로고
    • The original one-stage dental implant system and its clinical application
    • Buser D., Belser U.C., Lang N.P. The original one-stage dental implant system and its clinical application. Periodontol 2000. 17:1998;106-118.
    • (1998) Periodontol 2000 , vol.17 , pp. 106-118
    • Buser, D.1    Belser, U.C.2    Lang, N.P.3
  • 5
    • 0031612903 scopus 로고    scopus 로고
    • Influence of restoration type on stress distribution in bone around implants: A three-dimensional finite element analysis
    • Stegaroiu R., Sato T., Kusakari H., Miyakawa O. Influence of restoration type on stress distribution in bone around implants: a three-dimensional finite element analysis. Int J Oral Maxillofac Implants. 13:1998;82-90.
    • (1998) Int J Oral Maxillofac Implants , vol.13 , pp. 82-90
    • Stegaroiu, R.1    Sato, T.2    Kusakari, H.3    Miyakawa, O.4
  • 6
    • 0036514370 scopus 로고    scopus 로고
    • Finite element analysis on dental implant-supported prostheses without passive fit
    • Kunavisarut C., Lang L.A., Stoner B.R., Felton D.A. Finite element analysis on dental implant-supported prostheses without passive fit. J Prosthodont. 11:2002;30-40.
    • (2002) J Prosthodont , vol.11 , pp. 30-40
    • Kunavisarut, C.1    Lang, L.A.2    Stoner, B.R.3    Felton, D.A.4
  • 7
    • 0019663098 scopus 로고
    • A 15-year study of osseointegrated implants in the treatment of the edentulous jaw
    • Adell R., Lekholm U., Rockler B., Brånemark P.I. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg. 10:1981;387-416.
    • (1981) Int J Oral Surg , vol.10 , pp. 387-416
    • Adell, R.1    Lekholm, U.2    Rockler, B.3    Brånemark, P.I.4
  • 8
    • 0028685783 scopus 로고
    • Comparative three-dimensional analysis of two finite-element endosseous implant designs
    • Lozada J.L., Abbate M.F., Pizzarello F.A., James R.A. Comparative three-dimensional analysis of two finite-element endosseous implant designs. J Oral Implantol. 20:1994;315-321.
    • (1994) J Oral Implantol , vol.20 , pp. 315-321
    • Lozada, J.L.1    Abbate, M.F.2    Pizzarello, F.A.3    James, R.A.4
  • 9
    • 0020823258 scopus 로고
    • Osseointegration and its experimental background
    • Brånemark P.I. Osseointegration and its experimental background. J Prosthet Dent. 50:1983;399-410.
    • (1983) J Prosthet Dent , vol.50 , pp. 399-410
    • Brånemark, P.I.1
  • 10
    • 0030155422 scopus 로고    scopus 로고
    • Loss of osseointegration caused by occlusal load of oral implants. A clinical and radiographic study in monkeys
    • Isidor F. Loss of osseointegration caused by occlusal load of oral implants. A clinical and radiographic study in monkeys. Clin Oral Impl Res. 7:1996;143-152.
    • (1996) Clin Oral Impl Res , vol.7 , pp. 143-152
    • Isidor, F.1
  • 12
    • 0032198792 scopus 로고    scopus 로고
    • Finite element analysis of non-axial versus axial loading of oral implants in the mandible of the dog
    • Barbier L., Vander Sloten J., Krzesinski G., Schepers E., Van der Perre G. Finite element analysis of non-axial versus axial loading of oral implants in the mandible of the dog. J Oral Rehabil. 25:1998;847-858.
    • (1998) J Oral Rehabil , vol.25 , pp. 847-858
    • Barbier, L.1    Vander Sloten, J.2    Krzesinski, G.3    Schepers, E.4    Van Der Perre, G.5
  • 14
    • 0024151484 scopus 로고
    • Biomechanical considerations in dental implant design
    • Brunski J.B. Biomechanical considerations in dental implant design. Int J Oral Implantol. 5:1988;31-34.
    • (1988) Int J Oral Implantol , vol.5 , pp. 31-34
    • Brunski, J.B.1
  • 15
    • 0031986671 scopus 로고    scopus 로고
    • Evaluating parameters of osseointegrated dental implants using finite element analysis-a two-dimensional comparative study examining the effects of implant diameter, implant shape, and load direction
    • Holmgren E.P., Seckinger R.J., Kilgren L.M., Mante F. Evaluating parameters of osseointegrated dental implants using finite element analysis-a two-dimensional comparative study examining the effects of implant diameter, implant shape, and load direction. J Oral Implantol. 24:1998;80-88.
    • (1998) J Oral Implantol , vol.24 , pp. 80-88
    • Holmgren, E.P.1    Seckinger, R.J.2    Kilgren, L.M.3    Mante, F.4
  • 16
    • 0026892027 scopus 로고
    • Stress distribution around dental implants: Influence of superstructure, length of implants, and height of mandible
    • Meijer H.J., Kuiper J.H., Starmans F.J., Bosman F. Stress distribution around dental implants: influence of superstructure, length of implants, and height of mandible. J Prosthet Dent. 68:1992;96-102.
    • (1992) J Prosthet Dent , vol.68 , pp. 96-102
    • Meijer, H.J.1    Kuiper, J.H.2    Starmans, F.J.3    Bosman, F.4
  • 17
    • 0036134211 scopus 로고    scopus 로고
    • Comparative evaluation of the effect of diameter, length and number of implants supporting three-unit fixed partial prostheses on stress distribution in the bone
    • İplikçioĝlu H., Akça K. Comparative evaluation of the effect of diameter, length and number of implants supporting three-unit fixed partial prostheses on stress distribution in the bone. J Dent. 30:2002;41-46.
    • (2002) J Dent , vol.30 , pp. 41-46
    • Iplikçioĝlu, H.1    Akça, K.2
  • 18
    • 0027693217 scopus 로고
    • Numeric approach to the biomechanical analysis of thermal effects in coated implants
    • Moroi H.H., Okimoto K., Moroi R., Terada Y. Numeric approach to the biomechanical analysis of thermal effects in coated implants. Int J Prosthodont. 6:1993;564-572.
    • (1993) Int J Prosthodont , vol.6 , pp. 564-572
    • Moroi, H.H.1    Okimoto, K.2    Moroi, R.3    Terada, Y.4
  • 20
    • 0024815560 scopus 로고
    • Finite element analysis of three- and four-unit bridges
    • Farah J.W., Craig R.G., Meroueh K.A. Finite element analysis of three- and four-unit bridges. J Oral Rehabil. 16:1989;603-611.
    • (1989) J Oral Rehabil , vol.16 , pp. 603-611
    • Farah, J.W.1    Craig, R.G.2    Meroueh, K.A.3
  • 21
    • 0029303075 scopus 로고
    • Occlusal force and oral tactile sensibility measured in partially edentulous patients with ITI implants
    • Mericske-Stern R., Assal P., Mericske E., Burgin W. Occlusal force and oral tactile sensibility measured in partially edentulous patients with ITI implants. Int J Oral Maxillofac Implants. 10:1995;345-353.
    • (1995) Int J Oral Maxillofac Implants , vol.10 , pp. 345-353
    • Mericske-Stern, R.1    Assal, P.2    Mericske, E.3    Burgin, W.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.