메뉴 건너뛰기




Volumn 37, Issue 5, 1997, Pages 502-506

Detection and differentiation of platelet-specific antibodies by flow cytometry: The bead-mediated platelet assay

Author keywords

[No Author keywords available]

Indexed keywords

GLYCOPROTEIN; THROMBOCYTE ANTIBODY;

EID: 1842336903     PISSN: 00411132     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1537-2995.1997.37597293881.x     Document Type: Article
Times cited : (13)

References (19)
  • 1
    • 0025767789 scopus 로고
    • Neonatal alloimmune thrombocytopenia due to anti-Brb (HPA-5a). Report of three cases in two families
    • Kiefel V, Shechter Y, Atias D, et al. Neonatal alloimmune thrombocytopenia due to anti-Brb (HPA-5a). Report of three cases in two families (letter). Vox Sang 1991;60:244-5.
    • (1991) Vox Sang , vol.60 , pp. 244-245
    • Kiefel, V.1    Shechter, Y.2    Atias, D.3
  • 2
    • 0029055678 scopus 로고
    • Maternal alloimmunization against fetal platelet antigens: A prospective study
    • Panzer S, Auerbach L, Cechova E, et al. Maternal alloimmunization against fetal platelet antigens: a prospective study. Br J Haematol 1995;90:655-60.
    • (1995) Br J Haematol , vol.90 , pp. 655-660
    • Panzer, S.1    Auerbach, L.2    Cechova, E.3
  • 3
    • 0026920407 scopus 로고
    • The MAIPA assay and its applications in immunohaematology
    • Kiefel V. The MAIPA assay and its applications in immunohaematology. Transfus Med 1992;2:181-8.
    • (1992) Transfus Med , vol.2 , pp. 181-188
    • Kiefel, V.1
  • 4
    • 0023553379 scopus 로고
    • Serial measurement of lymphocytotoxic antibody and response to nonmatched platelet transfusions in alloimmunized patients
    • Lee EJ, Schiffer CA. Serial measurement of lymphocytotoxic antibody and response to nonmatched platelet transfusions in alloimmunized patients. Blood 1987;70:1727-9.
    • (1987) Blood , vol.70 , pp. 1727-1729
    • Lee, E.J.1    Schiffer, C.A.2
  • 5
    • 0028825811 scopus 로고
    • Flow cytometric analysis in platelet crossmatching using a platelet suspension immunofluorescence test
    • Skogen B, Christiansen D, Husebekk A. Flow cytometric analysis in platelet crossmatching using a platelet suspension immunofluorescence test. Transfusion 1995;35:832-6.
    • (1995) Transfusion , vol.35 , pp. 832-836
    • Skogen, B.1    Christiansen, D.2    Husebekk, A.3
  • 6
    • 9244243041 scopus 로고    scopus 로고
    • Flow cytometric detection of platelet-reactive antibodies and application in platelet crossmatching
    • Köhler M, Dittmann J, Legler TJ, et al. Flow cytometric detection of platelet-reactive antibodies and application in platelet crossmatching. Transfusion 1996;36:250-5.
    • (1996) Transfusion , vol.36 , pp. 250-255
    • Köhler, M.1    Dittmann, J.2    Legler, T.J.3
  • 7
    • 0018184678 scopus 로고
    • A simple immunofluorescence test for the detection of platelet anti-bodies
    • Von dem Borne AE, Verbeugt FW, Oosterhof F, et al. A simple immunofluorescence test for the detection of platelet anti-bodies. Br J Haematol 1978;39:195-207.
    • (1978) Br J Haematol , vol.39 , pp. 195-207
    • Von Dem Borne, A.E.1    Verbeugt, F.W.2    Oosterhof, F.3
  • 8
    • 0021982877 scopus 로고
    • Chloroquine removal of HLA antigens from platelets for the platelet immunofluorescence test
    • Nordhagen R, Flaathen ST. Chloroquine removal of HLA antigens from platelets for the platelet immunofluorescence test. Vox Sang 1985;48:156-9.
    • (1985) Vox Sang , vol.48 , pp. 156-159
    • Nordhagen, R.1    Flaathen, S.T.2
  • 9
    • 0021364892 scopus 로고
    • Autoantibodies against the platelet glycoprotein IIb/IIIa complex in patients with chronic ITP
    • Woods VL Jr, Oh EH, Mason D, McMillan R. Autoantibodies against the platelet glycoprotein IIb/IIIa complex in patients with chronic ITP. Blood 1984;63:368-75.
    • (1984) Blood , vol.63 , pp. 368-375
    • Woods Jr., V.L.1    Oh, E.H.2    Mason, D.3    McMillan, R.4
  • 11
    • 0023607547 scopus 로고
    • Monoclonal antibody-specific immobilization of platelet antigens (MAIPA): A new tool for the identification of platelet-reactive antibodies
    • Kiefel V, Santoso S, Weisheit M, et al. Monoclonal antibody-specific immobilization of platelet antigens (MAIPA): a new tool for the identification of platelet-reactive antibodies. Blood 1987;70:1722-6.
    • (1987) Blood , vol.70 , pp. 1722-1726
    • Kiefel, V.1    Santoso, S.2    Weisheit, M.3
  • 12
    • 0025936005 scopus 로고
    • Human platelet-specific antigen, Siba, is associated with the molecular weight polymorphism of glycoprotein Ib alpha
    • Ishida F, Saji H, Maruya E, Furihata K. Human platelet-specific antigen, Siba, is associated with the molecular weight polymorphism of glycoprotein Ib alpha. Blood 1991;78:1722-9.
    • (1991) Blood , vol.78 , pp. 1722-1729
    • Ishida, F.1    Saji, H.2    Maruya, E.3    Furihata, K.4
  • 13
    • 0028829057 scopus 로고
    • Fluorescence resonance energy transfer as a new method for the epitope-specific characterization of anti-platelet antibodies
    • Koksch M, Rothe G, Kiefel V, Schmitz G. Fluorescence resonance energy transfer as a new method for the epitope-specific characterization of anti-platelet antibodies. J Immunol Methods 1995;187:53-67.
    • (1995) J Immunol Methods , vol.187 , pp. 53-67
    • Koksch, M.1    Rothe, G.2    Kiefel, V.3    Schmitz, G.4
  • 14
    • 0030049040 scopus 로고    scopus 로고
    • Report on the Sixth International Society of Blood Transfusion Platelet Serology Workshop
    • Teramura G, Slichter SJ. Report on the Sixth International Society of Blood Transfusion Platelet Serology Workshop. Transfusion 1996;36:75-81.
    • (1996) Transfusion , vol.36 , pp. 75-81
    • Teramura, G.1    Slichter, S.J.2
  • 15
    • 0027531456 scopus 로고
    • A rapid and sensitive immunoassay for antibodies against alloantigens on human platelet glycoproteins (BIPA)
    • Loliger C, Ruhlmann E, Kuhnl P. A rapid and sensitive immunoassay for antibodies against alloantigens on human platelet glycoproteins (BIPA). J Immunol Methods 1993;158:197-200.
    • (1993) J Immunol Methods , vol.158 , pp. 197-200
    • Loliger, C.1    Ruhlmann, E.2    Kuhnl, P.3
  • 16
    • 0028985178 scopus 로고
    • A1 (HPA-1a): A comparison of flow cytometric immunophenotyping and genotyping using polymerase chain reaction and restriction fragment length polymorphism in a Swedish blood donor population
    • A1 (HPA-1a): a comparison of flow cytometric immunophenotyping and genotyping using polymerase chain reaction and restriction fragment length polymorphism in a Swedish blood donor population. Transfusion 1995;35:241-6.
    • (1995) Transfusion , vol.35 , pp. 241-246
    • Forsberg, B.1    Jacobsson, S.2    Stockelberg, D.3
  • 17
    • 0025735402 scopus 로고
    • The detection of platelet alloantibodies by flow cytometry
    • Worfolk LA, MacPherson BR. The detection of platelet alloantibodies by flow cytometry. Transfusion 1991;31:340-4.
    • (1991) Transfusion , vol.31 , pp. 340-344
    • Worfolk, L.A.1    MacPherson, B.R.2
  • 19
    • 0024345973 scopus 로고
    • Immunochemical characterization of the new platelet alloantigen system Bra/Brb
    • Santoso S, Kiefel V, Mueller-Eckhardt C. Immunochemical characterization of the new platelet alloantigen system Bra/Brb. Br J Haematol 1989;72:191-8.
    • (1989) Br J Haematol , vol.72 , pp. 191-198
    • Santoso, S.1    Kiefel, V.2    Mueller-Eckhardt, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.