메뉴 건너뛰기




Volumn 164, Issue 5, 1996, Pages 401-405

The value of velocity histograms of hepatic veins for the diagnosis of liver cirrhosis;BEDEUTUNG DES DUPLEX-GESCHWINDIGKEITSHISTOGRAMMS ZUR DIAGNOSE DER LEBERZIRRHOSE

Author keywords

Duplex; Hepatic veins; Liver cirrhosis; ultrasonography; Velocity histogram

Indexed keywords

ARTICLE; CLINICAL TRIAL; COLOR ULTRASOUND FLOWMETRY; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; HEPATIC VEIN; HISTOGRAM; HUMAN; HUMAN EXPERIMENT; IMAGE ANALYSIS; LIVER CIRRHOSIS; NORMAL HUMAN; PRIORITY JOURNAL;

EID: 1842331339     PISSN: 09366652     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (5)

References (15)
  • 4
    • 0027055206 scopus 로고
    • Normal and respiratory variations of the hepatic veins and portal venous duplex Doppler waveforms with simultaneous electrocardiographic correlation
    • Abu-Yousef, M. M.: Normal and respiratory variations of the hepatic veins and portal venous duplex Doppler waveforms with simultaneous electrocardiographic correlation. J. Ultrasound. Med. 11 (1992) 263-268
    • (1992) J. Ultrasound. Med. , vol.11 , pp. 263-268
    • Abu-Yousef, M.M.1
  • 5
    • 0026097822 scopus 로고
    • Duplex Doppler sonography of the hepatic vein tricuspid regurgitation
    • Abu-Yousef, M. M.: Duplex Doppler sonography of the hepatic vein tricuspid regurgitation. Amer. J. Roentgenol. 156 (1991) 79-83
    • (1991) Amer. J. Roentgenol. , vol.156 , pp. 79-83
    • Abu-Yousef, M.M.1
  • 7
    • 0025790560 scopus 로고
    • Zur Aussagefähigkeit der quantitativen Doppler-Ultraschall-Signal-Analyse in der Diagnostik postoperativer Organdysfunktion nach orthotoper Lebertransplantation
    • Harms, J., D. Ysebaert, B. Ringe, M. Gebel, R. Pichelmayr: Zur Aussagefähigkeit der quantitativen Doppler-Ultraschall-Signal-Analyse in der Diagnostik postoperativer Organdysfunktion nach orthotoper Lebertransplantation. J. Vasc. Dis. 33 (1991) 84-85
    • (1991) J. Vasc. Dis. , vol.33 , pp. 84-85
    • Harms, J.1    Ysebaert, D.2    Ringe, B.3    Gebel, M.4    Pichelmayr, R.5
  • 11
    • 0028144535 scopus 로고
    • Analysis of hepatic vein waveforms by Doppler ultrasonography in 100 patients with portal hypertension
    • Ohta, M., M. Hashizume, M. Tomikawa, K. Ueno, K. Tanoue, K. Sugimachi: Analysis of hepatic vein waveforms by Doppler ultrasonography in 100 patients with portal hypertension. Amer. J. Gastroenterol. 89 (1994) 170-175
    • (1994) Amer. J. Gastroenterol. , vol.89 , pp. 170-175
    • Ohta, M.1    Hashizume, M.2    Tomikawa, M.3    Ueno, K.4    Tanoue, K.5    Sugimachi, K.6
  • 13
    • 0022363783 scopus 로고
    • Local histogram information content of ultrasound B-mode echographic texture
    • Mailloux, G. E., M. Biertrand, R. Stampfler: Local histogram information content of ultrasound B-mode echographic texture. Ultrasound. Med. & Biol. 11 (1985) 743-750
    • (1985) Ultrasound. Med. & Biol. , vol.11 , pp. 743-750
    • Mailloux, G.E.1    Biertrand, M.2    Stampfler, R.3
  • 15
    • 0026217549 scopus 로고
    • Doppler flow velocity patterns of the superior vena cava, inferior vena cava, hepatic vein, coronary sinus, and atrial septal defect: A guide for the echocardiographer
    • Reynolds, T., C. P. Appleton: Doppler flow velocity patterns of the superior vena cava, inferior vena cava, hepatic vein, coronary sinus, and atrial septal defect: A guide for the echocardiographer. J. Amer. Soc. Echocardiogr. 4 (1991) 503-512
    • (1991) J. Amer. Soc. Echocardiogr. , vol.4 , pp. 503-512
    • Reynolds, T.1    Appleton, C.P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.