-
1
-
-
0024402107
-
Retinal ganglion cell atrophy correlated with automated perimetry in human eyes with glaucoma
-
H.A. Quigley, G.R. Dunkelberger, W.R. Green Retinal ganglion cell atrophy correlated with automated perimetry in human eyes with glaucoma Am J Ophthalmol 107 1989 453 464
-
(1989)
Am J Ophthalmol
, vol.107
, pp. 453-464
-
-
Quigley, H.A.1
Dunkelberger, G.R.2
Green, W.R.3
-
2
-
-
0344329377
-
Ganglion cell losses underlying visual field defects from experimental glaucoma
-
R.S. Harwerth, L. Carter-Dawson, F. Shen Ganglion cell losses underlying visual field defects from experimental glaucoma Invest Ophthalmol Vis Sci 40 1999 2242 2250
-
(1999)
Invest Ophthalmol Vis Sci
, vol.40
, pp. 2242-2250
-
-
Harwerth, R.S.1
Carter-Dawson, L.2
Shen, F.3
-
3
-
-
0037386712
-
Correlation among retinal thickness, optic disc, and visual field in glaucoma patients and suspects: A pilot study
-
S. Asrani, P. Challa, L. Herndon Correlation among retinal thickness, optic disc, and visual field in glaucoma patients and suspects a pilot study J Glaucoma 12 2003 119 128
-
(2003)
J Glaucoma
, vol.12
, pp. 119-128
-
-
Asrani, S.1
Challa, P.2
Herndon, L.3
-
4
-
-
0031770658
-
Identification of early glaucoma cases with the scanning laser ophthalmoscope
-
G. Wollstein, D. Garway-Heath, R. Hitchings Identification of early glaucoma cases with the scanning laser ophthalmoscope Ophthalmology 105 1998 1557 1563
-
(1998)
Ophthalmology
, vol.105
, pp. 1557-1563
-
-
Wollstein, G.1
Garway-Heath, D.2
Hitchings, R.3
-
6
-
-
0036808571
-
Optical coherence tomography measurement of nerve fiber layer thickness and the likelihood of a visual field defect
-
Z.Y. Williams, J.S. Schuman, L. Gamell Optical coherence tomography measurement of nerve fiber layer thickness and the likelihood of a visual field defect Am J Ophthalmol 134 2002 538 546
-
(2002)
Am J Ophthalmol
, vol.134
, pp. 538-546
-
-
Williams, Z.Y.1
Schuman, J.S.2
Gamell, L.3
-
7
-
-
0036138991
-
Comparison of optic nerve imaging methods to distinguish normal eyes from those with glaucoma
-
M.J. Greaney, D.C. Hoffman, D.F. Garway-Heath Comparison of optic nerve imaging methods to distinguish normal eyes from those with glaucoma Invest Ophthalmol Vis Sci 43 2002 140 145
-
(2002)
Invest Ophthalmol Vis Sci
, vol.43
, pp. 140-145
-
-
Greaney, M.J.1
Hoffman, D.C.2
Garway-Heath, D.F.3
-
8
-
-
0037385289
-
Comparison of algorithms for detection of localised nerve fibre layer defects using scanning laser polarimetry
-
F.A. Medeiros, R. Susanna Jr Comparison of algorithms for detection of localised nerve fibre layer defects using scanning laser polarimetry Br J Ophthalmol 87 2003 413 419
-
(2003)
Br J Ophthalmol
, vol.87
, pp. 413-419
-
-
Medeiros, F.A.1
Susanna Jr., R.2
-
9
-
-
0037314187
-
Glaucoma detection using scanning laser polarimetry with variable corneal polarization compensation
-
R.N. Weinreb, C. Bowd, L.M. Zangwill Glaucoma detection using scanning laser polarimetry with variable corneal polarization compensation Arch Ophthalmol 121 2003 218 224
-
(2003)
Arch Ophthalmol
, vol.121
, pp. 218-224
-
-
Weinreb, R.N.1
Bowd, C.2
Zangwill, L.M.3
-
10
-
-
0031955730
-
Quantitative evaluation of the optic nerve head in early glaucoma
-
D.F. Garway-Heath, R.A. Hitchings Quantitative evaluation of the optic nerve head in early glaucoma Br J Ophthalmol 82 1998 352 361
-
(1998)
Br J Ophthalmol
, vol.82
, pp. 352-361
-
-
Garway-Heath, D.F.1
Hitchings, R.A.2
-
11
-
-
0016317808
-
Use of photographs for measuring cupping in the optic disc
-
J. Gloster, D.G. Parry Use of photographs for measuring cupping in the optic disc Br J Ophthalmol 58 1974 850 862
-
(1974)
Br J Ophthalmol
, vol.58
, pp. 850-862
-
-
Gloster, J.1
Parry, D.G.2
-
12
-
-
0023157224
-
The area of the neuroretinal rim of the optic nerve in normal eyes
-
R.J. Britton, S.M. Drance, M. Schulzer The area of the neuroretinal rim of the optic nerve in normal eyes Am J Ophthalmol 103 1987 497 504
-
(1987)
Am J Ophthalmol
, vol.103
, pp. 497-504
-
-
Britton, R.J.1
Drance, S.M.2
Schulzer, M.3
-
13
-
-
0024599154
-
Agreement between clinicians and an image analyzer in estimating cup-to-disc ratios
-
R. Varma, G. Spaeth, W. Steinmann, L.J. Katz Agreement between clinicians and an image analyzer in estimating cup-to-disc ratios Arch Ophthalmol 107 1989 526 529
-
(1989)
Arch Ophthalmol
, vol.107
, pp. 526-529
-
-
Varma, R.1
Spaeth, G.2
Steinmann, W.3
Katz, L.J.4
-
14
-
-
0032949282
-
Software for 3-D visualization/analysis of optic-disc images
-
K. Yogesan, C.J. Barry, L. Jitskaia Software for 3-D visualization/ analysis of optic-disc images IEEE Eng Med Biol Mag 18 1999 43 49
-
(1999)
IEEE Eng Med Biol Mag
, vol.18
, pp. 43-49
-
-
Yogesan, K.1
Barry, C.J.2
Jitskaia, L.3
-
16
-
-
18244393830
-
Assessment of digital stereoscopic optic disc images using a Z screen
-
D.B. Hensen M. Wall The Hague Kluger
-
J.E. Morgan, N.J. Sheen, R. Goyal Assessment of digital stereoscopic optic disc images using a Z screen D.B. Hensen M. Wall Perimetry Update 2002/2003. Proceedings of the XVth International Perimetric Society Meeting, Stratford-upon-Avon, England, June 26-9, 2002 2003 The Hague Kluger 309 316
-
(2003)
Perimetry Update 2002/2003. Proceedings of the XVth International Perimetric Society Meeting, Stratford-upon-Avon, England, June 26-9, 2002
, pp. 309-316
-
-
Morgan, J.E.1
Sheen, N.J.2
Goyal, R.3
-
17
-
-
0031659876
-
Sources of bias in studies of optic disc and retinal nerve fibre layer morphology
-
D.F. Garway-Heath, R.A. Hitchings Sources of bias in studies of optic disc and retinal nerve fibre layer morphology Br J Ophthalmol 82 1998 986
-
(1998)
Br J Ophthalmol
, vol.82
, pp. 986
-
-
Garway-Heath, D.F.1
Hitchings, R.A.2
-
18
-
-
0026717105
-
Glaucoma Hemifield Test. Automated visual field evaluation
-
P. Asman, A. Heijl Glaucoma Hemifield Test. Automated visual field evaluation Arch Ophthalmol 110 1992 812 819
-
(1992)
Arch Ophthalmol
, vol.110
, pp. 812-819
-
-
Asman, P.1
Heijl, A.2
-
20
-
-
11244325506
-
Evaluation of automated perimetry
-
A. Litvak Butterworth-Heinemann Boston
-
P.A. Lalle Evaluation of automated perimetry A. Litvak Glaucoma Handbook 2001 Butterworth-Heinemann Boston 97 167
-
(2001)
Glaucoma Handbook
, pp. 97-167
-
-
Lalle, P.A.1
-
22
-
-
0031778648
-
Measurement of optic disc size: Equivalence of methods to correct for ocular magnification
-
D.F. Garway-Heath, A.R. Rudnicka, T. Lowe Measurement of optic disc size equivalence of methods to correct for ocular magnification Br J Ophthalmol 82 1998 643 649
-
(1998)
Br J Ophthalmol
, vol.82
, pp. 643-649
-
-
Garway-Heath, D.F.1
Rudnicka, A.R.2
Lowe, T.3
-
25
-
-
0023503113
-
Optic disc rim area is related to disc size in normal subjects
-
J. Caprioli, J.M. Miller Optic disc rim area is related to disc size in normal subjects Arch Ophthalmol 105 1987 1683 1685
-
(1987)
Arch Ophthalmol
, vol.105
, pp. 1683-1685
-
-
Caprioli, J.1
Miller, J.M.2
-
28
-
-
0032580377
-
Interval estimation for the difference between independent proportions: Comparison of eleven methods
-
R.G. Newcombe Interval estimation for the difference between independent proportions comparison of eleven methods Stat Med 17 1998 873 890
-
(1998)
Stat Med
, vol.17
, pp. 873-890
-
-
Newcombe, R.G.1
-
30
-
-
0028485648
-
Interocular suppression produced by rivalry stimuli: A comparison of normal and abnormal binocular vision
-
E.L. Smith III, K. Fern, R. Manny, R.S. Harwerth Interocular suppression produced by rivalry stimuli a comparison of normal and abnormal binocular vision Optom Vis Sci 71 1994 479 491
-
(1994)
Optom Vis Sci
, vol.71
, pp. 479-491
-
-
Smith III, E.L.1
Fern, K.2
Manny, R.3
Harwerth, R.S.4
-
31
-
-
0032813753
-
Optic disk appearances in primary open-angle glaucoma
-
D.C. Broadway, M.T. Nicolela, S.M. Drance Optic disk appearances in primary open-angle glaucoma Surv Ophthalmol 43 suppl 1999 S223 S243
-
(1999)
Surv Ophthalmol
, vol.43
, Issue.SUPPL.
-
-
Broadway, D.C.1
Nicolela, M.T.2
Drance, S.M.3
|