-
1
-
-
0020585057
-
Unicompartmental knee arthroplasty for single compartment disease
-
D.K. Bae J.F. Guhl S.P. Keane Unicompartmental knee arthroplasty for single compartment disease Clin. Orthop. 176 1983 233-238
-
(1983)
Clin. Orthop.
, vol.176
, pp. 233-238
-
-
Bae, D.K.1
Guhl, J.F.2
Keane, S.P.3
-
2
-
-
0025360761
-
Normal axial alignment of the lower extremity and load-bearing distribution at the knee
-
R.W.W. Hsu S. Himeno M.B. Coventry E.Y.S. Chao Normal axial alignment of the lower extremity and load-bearing distribution at the knee Clin. Orthop. 255 1990 215-227
-
(1990)
Clin. Orthop.
, vol.255
, pp. 215-227
-
-
Hsu, R.W.W.1
Himeno, S.2
Coventry, M.B.3
Chao, E.Y.S.4
-
3
-
-
0019397401
-
A detailed comparison of experimental and theoretical stress analyses of a human femur
-
Mechanical properties of bone
-
Huiskes R, Janssen JD, Slooff TJ. A detailed comparison of experimental and theoretical stress analyses of a human femur. In: Mechanical properties of bone. Proceedings of the Joint ASME-ASCE Applied Mechanics, Fluids Engineering and Bioengineering Conference AMD, vol. 45, 1981. 211-34
-
(1981)
Proceedings of the Joint ASME-ASCE Applied Mechanics, Fluids Engineering and Bioengineering Conference AMD
, vol.45
, pp. 211-234
-
-
Huiskes, R.1
Janssen, J.D.2
Slooff, T.J.3
-
4
-
-
0036273426
-
The effects of tibial component inclination on bone stress after unicompartmental knee arthroplasty
-
K. Iesaka H. Tsumura H. Sonoda et al. The effects of tibial component inclination on bone stress after unicompartmental knee arthroplasty J. Biomech. 35 2002 969-974
-
(2002)
J. Biomech.
, vol.35
, pp. 969-974
-
-
Iesaka, K.1
Tsumura, H.2
Sonoda, H.3
-
5
-
-
34250295520
-
Mechanics of biological tissues - A review
-
I.V. Knets A. Malmeisters Mechanics of biological tissues - a review Polym. Mech. 13 1978 434-440
-
(1978)
Polym. Mech.
, vol.13
, pp. 434-440
-
-
Knets, I.V.1
Malmeisters, A.2
-
6
-
-
0032123274
-
Yield strain behavior of trabecular bone
-
D.L. Kopperdahl T.M. Keaveny Yield strain behavior of trabecular bone J. Biomech. 31 1998 601-608
-
(1998)
J. Biomech.
, vol.31
, pp. 601-608
-
-
Kopperdahl, D.L.1
Keaveny, T.M.2
-
7
-
-
0033863615
-
The introduction period of unicompartmental knee arthroplasty is critical
-
A. Lindstrand A. Stenström The introduction period of unicompartmental knee arthroplasty is critical J. Arthroplasty 15 2000 608-616
-
(2000)
J. Arthroplasty
, vol.15
, pp. 608-616
-
-
Lindstrand, A.1
Stenström, A.2
-
9
-
-
0033816740
-
Analysis of a femoral hip prosthesis designed to reduce stress shielding
-
G.J. Makarand G.A. Suresh M. Freeman H.S. Michael Analysis of a femoral hip prosthesis designed to reduce stress shielding J. Biomech. 33 2000 1655-1662
-
(2000)
J. Biomech.
, vol.33
, pp. 1655-1662
-
-
Makarand, G.J.1
Suresh, G.A.2
Freeman, M.3
Michael, H.S.4
-
10
-
-
0015694790
-
The modular knee
-
L. Marmor The modular knee Clin. Orthop. 94 1973 242-248
-
(1973)
Clin. Orthop.
, vol.94
, pp. 242-248
-
-
Marmor, L.1
-
11
-
-
0023851675
-
Unicompartmental knee arthroplasty: Ten to thirteen year follow-up study
-
L. Marmor Unicompartmental knee arthroplasty: Ten to thirteen year follow-up study Clin. Orthop. 226 1988 14-20
-
(1988)
Clin. Orthop.
, vol.226
, pp. 14-20
-
-
Marmor, L.1
-
12
-
-
0035055590
-
Dependence of yield strain of human trabecular bone on anatomic site
-
E.F. Morgan T.M. Keaveny Dependence of yield strain of human trabecular bone on anatomic site J. Biomech. 34 2001 569-577
-
(2001)
J. Biomech.
, vol.34
, pp. 569-577
-
-
Morgan, E.F.1
Keaveny, T.M.2
-
13
-
-
0015667763
-
Elastic and viscoelastic properties of trabecular bone: Dependence on structure
-
J.W. Pugh R.M. Rose E. Radin Elastic and viscoelastic properties of trabecular bone: Dependence on structure J. Biomech. 6 1973 475-485
-
(1973)
J. Biomech.
, vol.6
, pp. 475-485
-
-
Pugh, J.W.1
Rose, R.M.2
Radin, E.3
-
14
-
-
0027551874
-
Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements
-
J.Y. Rho R.B. Ashman C.H. Turner Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements J. Biomech. 26 1993 111-119
-
(1993)
J. Biomech.
, vol.26
, pp. 111-119
-
-
Rho, J.Y.1
Ashman, R.B.2
Turner, C.H.3
-
15
-
-
0019508227
-
Unicondylar unicompartmental replacement for osteoarthritis of the knee
-
R.D. Scott R.F. Santore Unicondylar unicompartmental replacement for osteoarthritis of the knee J. Bone Joint Surg. [Am] 63 1981 536-544
-
(1981)
J. Bone Joint Surg. [Am]
, vol.63
, pp. 536-544
-
-
Scott, R.D.1
Santore, R.F.2
-
16
-
-
4243543188
-
The 5-year results of a prospective randomized trial of unicompartmental of total knee replacement
-
Presented at the AAOS, NewOrleans
-
Shah NA, Newman JH, Ackroyd CE. The 5-year results of a prospective randomized trial of unicompartmental of total knee replacement. Presented at the AAOS, NewOrleans, 1998
-
(1998)
-
-
Shah, N.A.1
Newman, J.H.2
Ackroyd, C.E.3
-
17
-
-
0024541804
-
Medial unicompartmental arthoroplasty of the knee
-
J. Swienckowski B.J. Page II Medial unicompartmental arthoroplasty of the knee Clin. Orthop. 239 1989 161-167
-
(1989)
Clin. Orthop.
, vol.239
, pp. 161-167
-
-
Swienckowski, J.1
Page II, B.J.2
-
18
-
-
0029559822
-
Finite element modeling - A predictor of implant survival?
-
M. Taylor K.E. Tanner Finite element modeling - a predictor of implant survival? J. Mater. Sci. 6 1995 808-815
-
(1995)
J. Mater. Sci.
, vol.6
, pp. 808-815
-
-
Taylor, M.1
Tanner, K.E.2
-
19
-
-
0030987956
-
Fatigue failure of cancellous bone: A possible cause of implanted migration and loosening
-
M. Taylor K.E. Tanner Fatigue failure of cancellous bone: A possible cause of implanted migration and loosening J. Bone Joint Surg. [Br] 79 1997 181-182
-
(1997)
J. Bone Joint Surg. [Br]
, vol.79
, pp. 181-182
-
-
Taylor, M.1
Tanner, K.E.2
-
20
-
-
0029380382
-
Cancellous bone stresses surrounding the femoral component of a hip prothesis: An elastic-plastic finite element analysis
-
M. Taylor K.E. Tanner M. Freeman et al. Cancellous bone stresses surrounding the femoral component of a hip prothesis: An elastic-plastic finite element analysis Med. Eng. Phys. 17 1995 544-550
-
(1995)
Med. Eng. Phys.
, vol.17
, pp. 544-550
-
-
Taylor, M.1
Tanner, K.E.2
Freeman, M.3
-
21
-
-
0032053031
-
Finite element analysis of the implanted proximal tibia: A relationship between the initial cancellous bone stresses and implant migration
-
M. Taylor K.E. Tanner M. Freeman Finite element analysis of the implanted proximal tibia: A relationship between the initial cancellous bone stresses and implant migration J. Biomech. 31 1998 303-310
-
(1998)
J. Biomech.
, vol.31
, pp. 303-310
-
-
Taylor, M.1
Tanner, K.E.2
Freeman, M.3
-
22
-
-
0022456873
-
Epiphyseal-based designs for tibial plateau components - I. Stress analysis in the frontal plane
-
R. Vasu D.R. Carter D.J. Schuman G.S. Beaupre Epiphyseal-based designs for tibial plateau components - I. Stress analysis in the frontal plane J. Biomech. 19 1986 647-662
-
(1986)
J. Biomech.
, vol.19
, pp. 647-662
-
-
Vasu, R.1
Carter, D.R.2
Schuman, D.J.3
Beaupre, G.S.4
|