메뉴 건너뛰기




Volumn 27, Issue 5, 2005, Pages 425-434

Expansion anchors for use in anterior cruciate ligament (ACL) reconstruction: Establishing proof of concept in a benchtop analysis

Author keywords

Anterior cruciate ligament reconstruction; Expansion anchors; Implant design; Mechanical testing; Prototype development

Indexed keywords

BIOMECHANICS; BIOMEDICAL ENGINEERING; BONE; GRAFTS;

EID: 18044386535     PISSN: 13504533     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.medengphy.2004.11.004     Document Type: Article
Times cited : (3)

References (19)
  • 1
    • 0034832609 scopus 로고    scopus 로고
    • Biomechanical properties of interference screw implantation in replacement of the anterior cruciate ligament with patellar and hamstring transplants. An experimental study using roentgen stereometry analysis
    • F. Adam, D. Pape, O. Steimer, D. Kohn, and S. Rupp Biomechanical properties of interference screw implantation in replacement of the anterior cruciate ligament with patellar and hamstring transplants. An experimental study using roentgen stereometry analysis Orthopade 30 9 2001 649 657
    • (2001) Orthopade , vol.30 , Issue.9 , pp. 649-657
    • Adam, F.1    Pape, D.2    Steimer, O.3    Kohn, D.4    Rupp, S.5
  • 2
    • 0033677953 scopus 로고    scopus 로고
    • Effects of interference screw length on tibial tunnel fixation for anterior cruciate ligament reconstruction
    • K.P. Black, M.M. Saunders, K.C. Stube, M.J.R. Moulton, and C.R. Jacobs Effects of interference screw length on tibial tunnel fixation for anterior cruciate ligament reconstruction Am J Sports Med 28 2000 846 849
    • (2000) Am J Sports Med , vol.28 , pp. 846-849
    • Black, K.P.1    Saunders, M.M.2    Stube, K.C.3    Moulton, M.J.R.4    Jacobs, C.R.5
  • 4
    • 0027508563 scopus 로고
    • The biomechanics of interference screw fixation of patellar tendon anterior cruciate ligament grafts
    • C.H. Brown, T.H. Aaron, J.A. Hipp, E.R. Myers, and H.C. Wilson The biomechanics of interference screw fixation of patellar tendon anterior cruciate ligament grafts Am J Sports Med 21 6 1993 880 886
    • (1993) Am J Sports Med , vol.21 , Issue.6 , pp. 880-886
    • Brown, C.H.1    Aaron, T.H.2    Hipp, J.A.3    Myers, E.R.4    Wilson, H.C.5
  • 5
    • 0034234476 scopus 로고    scopus 로고
    • Bioabsorbable polyglyconate interference screw fixation in anterior cruciate ligament reconstruction: A prospective computed tomography-controlled study
    • C. Fink, K.P. Benedetto, W. Hacki, C. Hoser, M.C. Freund, and M. Rieger Bioabsorbable polyglyconate interference screw fixation in anterior cruciate ligament reconstruction: a prospective computed tomography-controlled study Arthroscopy 16 5 2000 491 498
    • (2000) Arthroscopy , vol.16 , Issue.5 , pp. 491-498
    • Fink, C.1    Benedetto, K.P.2    Hacki, W.3    Hoser, C.4    Freund, M.C.5    Rieger, M.6
  • 7
    • 0027275217 scopus 로고
    • Biomechanical evaluation of interference screw fixation in a bovine patellar bone-tendon-bone autograft complex for anterior cruciate ligament reconstruction
    • M. Hulstyn, P.D. Fadale, J. Abate, and W.R. Walsh Biomechanical evaluation of interference screw fixation in a bovine patellar bone-tendon-bone autograft complex for anterior cruciate ligament reconstruction J Arthrosc Rel Surg 9 4 1993 417 424
    • (1993) J Arthrosc Rel Surg , vol.9 , Issue.4 , pp. 417-424
    • Hulstyn, M.1    Fadale, P.D.2    Abate, J.3    Walsh, W.R.4
  • 8
    • 0028244250 scopus 로고
    • Primary stability of interference screw fixation Influence of screw diameter and insertion torque
    • D. Kohn, and C. Rose Primary stability of interference screw fixation Influence of screw diameter and insertion torque Am J Sports Med 22 1994 334 338
    • (1994) Am J Sports Med , vol.22 , pp. 334-338
    • Kohn, D.1    Rose, C.2
  • 9
    • 0023280269 scopus 로고
    • A biochemical comparison of different surgical techniques of graft fixation in anterior cruciate ligament reconstruction
    • M. Kurosaka, S. Yoshiya, and J.T. Andrish A biochemical comparison of different surgical techniques of graft fixation in anterior cruciate ligament reconstruction Am J Sports Med 15 3 1987 225 229
    • (1987) Am J Sports Med , vol.15 , Issue.3 , pp. 225-229
    • Kurosaka, M.1    Yoshiya, S.2    Andrish, J.T.3
  • 10
    • 0027414220 scopus 로고
    • Radiographic analysis of femoral interference screw placement during ACL reconstruction: Endoscopic versus open technique arthroscopy
    • M.J. Lemos, J. Albert, T. Simon, and D.W. Jackson Radiographic analysis of femoral interference screw placement during ACL reconstruction: endoscopic versus open technique arthroscopy J Arthrosc Rel Surg 9 2 1993 154 158
    • (1993) J Arthrosc Rel Surg , vol.9 , Issue.2 , pp. 154-158
    • Lemos, M.J.1    Albert, J.2    Simon, T.3    Jackson, D.W.4
  • 12
    • 0036590482 scopus 로고    scopus 로고
    • Interference screw divergence in femoral tunnel fixation during endoscopic anterior cruciate ligament reconstruction using hamstring grafts
    • C.M. Miller, J.E. Tibone, M. Hewitt, F.D. Kharrazi, and N.S. Elattrache Interference screw divergence in femoral tunnel fixation during endoscopic anterior cruciate ligament reconstruction using hamstring grafts Arthroscopy 18 5 2002 510 514
    • (2002) Arthroscopy , vol.18 , Issue.5 , pp. 510-514
    • Miller, C.M.1    Tibone, J.E.2    Hewitt, M.3    Kharrazi, F.D.4    Elattrache, N.S.5
  • 13
    • 0001897211 scopus 로고
    • A biomechanical comparison of interference versus postfixation of bone-patellar tendon-bone grafts for anterior cruciate ligament reconstruction
    • S.O. Paschal, M.D. Seeman, R.B. Ashman, and R.N. Allard A biomechanical comparison of interference versus postfixation of bone-patellar tendon-bone grafts for anterior cruciate ligament reconstruction Ortho Trans 16 1992 80
    • (1992) Ortho Trans , vol.16 , pp. 80
    • Paschal, S.O.1    Seeman, M.D.2    Ashman, R.B.3    Allard, R.N.4
  • 14
    • 0031967936 scopus 로고    scopus 로고
    • The effects of bone plug length and screw diameter on the holding strength of bone-tendon-bone grafts
    • G. Pomeroy, M. Baltz, K. Pierz, M. Nowak, W. Post, and J.P. Fulkerson The effects of bone plug length and screw diameter on the holding strength of bone-tendon-bone grafts J Arthrosc Rel Surg 14 2 1998 148 152
    • (1998) J Arthrosc Rel Surg , vol.14 , Issue.2 , pp. 148-152
    • Pomeroy, G.1    Baltz, M.2    Pierz, K.3    Nowak, M.4    Post, W.5    Fulkerson, J.P.6
  • 15
    • 0000707850 scopus 로고
    • Optimizing interference fixation for cruciate ligament reconstruction
    • A.M. Resnick Optimizing interference fixation for cruciate ligament reconstruction Trans Ortho Res Soc 15 1990 519
    • (1990) Trans Ortho Res Soc , vol.15 , pp. 519
    • Resnick, A.M.1
  • 16
    • 0032588699 scopus 로고    scopus 로고
    • Ligament graft initial fixation strength using biodegradable interference screws
    • S. Rupp, R. Seil, A. Schneider, and D.M. Kohn Ligament graft initial fixation strength using biodegradable interference screws J Biomed Mater 48 1 1999 70 74
    • (1999) J Biomed Mater , vol.48 , Issue.1 , pp. 70-74
    • Rupp, S.1    Seil, R.2    Schneider, A.3    Kohn, D.M.4
  • 17
    • 0036524466 scopus 로고    scopus 로고
    • Biomechancal comparison of hamstring and patellar tendon graft anterior cruciate ligament reconstruction techniques: The impact of fixation level and fixation method under cyclic loading
    • S.U. Scheffler, N.P. Sudkamp, A. Gockenjan, R.F. Hoffmann, and A. Weiler Biomechancal comparison of hamstring and patellar tendon graft anterior cruciate ligament reconstruction techniques: the impact of fixation level and fixation method under cyclic loading Arthroscopy 18 3 2002 304 315
    • (2002) Arthroscopy , vol.18 , Issue.3 , pp. 304-315
    • Scheffler, S.U.1    Sudkamp, N.P.2    Gockenjan, A.3    Hoffmann, R.F.4    Weiler, A.5
  • 18
    • 0035353876 scopus 로고    scopus 로고
    • Comparisons of intraosseous graft healing between the doubled flexor tendon graft and the bone-patellar tendon-bone graft in anterior cruciate ligament reconstruction
    • F. Tomita, K. Yasuda, S. Mikami, T. Sakai, S. Yamazaki, and H. Tohyama Comparisons of intraosseous graft healing between the doubled flexor tendon graft and the bone-patellar tendon-bone graft in anterior cruciate ligament reconstruction Arthroscopy 17 5 2001 461 476
    • (2001) Arthroscopy , vol.17 , Issue.5 , pp. 461-476
    • Tomita, F.1    Yasuda, K.2    Mikami, S.3    Sakai, T.4    Yamazaki, S.5    Tohyama, H.6
  • 19
    • 0033049738 scopus 로고    scopus 로고
    • Replacement of the anterior cruciate ligament. Biomechanical studies for patellar and semitendinosus tendon fixation with a poly (d,l-lactide) interference screw
    • A. Weiler, R.F. Hoffmann, N.P. Sudkamp, C.J. Siepe, and N.P. Haas Replacement of the anterior cruciate ligament. Biomechanical studies for patellar and semitendinosus tendon fixation with a poly (d,l-lactide) interference screw Unfallchirurg 102 2 1999 L115 L123
    • (1999) Unfallchirurg , vol.102 , Issue.2
    • Weiler, A.1    Hoffmann, R.F.2    Sudkamp, N.P.3    Siepe, C.J.4    Haas, N.P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.