메뉴 건너뛰기




Volumn 115, Issue 6, 2005, Pages 1674-1681

A biomechanical comparison of four extensor tendon repair techniques in zone IV

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BIOMECHANICS; CADAVER; FLEXOR TENDON; HUMAN; PRIORITY JOURNAL; STRENGTH; SURGICAL APPROACH; SURGICAL TECHNIQUE; SUTURING METHOD; TENDON RECONSTRUCTION; TENDON SUTURE;

EID: 18044373624     PISSN: 00321052     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.PRS.0000161463.83102.85     Document Type: Article
Times cited : (35)

References (18)
  • 1
    • 0029068709 scopus 로고
    • Biomechanical characteristics of suture techniques in extensor zone IV
    • Newport, M. L., Pollack, G. R., and Williams, C. D. Biomechanical characteristics of suture techniques in extensor zone IV. J. Hand Surg. (Am.) 20: 650, 1995.
    • (1995) J. Hand Surg. (Am.) , vol.20 , pp. 650
    • Newport, M.L.1    Pollack, G.R.2    Williams, C.D.3
  • 2
    • 0030955288 scopus 로고    scopus 로고
    • Biomechanical analysis of four-strand extensor tendon repair techniques
    • Howard, R. F., Ondrovic, L., and Greenwald, D. P. Biomechanical analysis of four-strand extensor tendon repair techniques. J. Hand Surg. (Am.) 22: 838, 1997.
    • (1997) J. Hand Surg. (Am.) , vol.22 , pp. 838
    • Howard, R.F.1    Ondrovic, L.2    Greenwald, D.P.3
  • 6
    • 0021067371 scopus 로고
    • Management and rehabilitation of extensor tendon injuries
    • Lovett, W. L., and McCall, M. A. Management and rehabilitation of extensor tendon injuries. Orthop. Clin. North Am. 44: 811, 1983.
    • (1983) Orthop. Clin. North Am. , vol.44 , pp. 811
    • Lovett, W.L.1    McCall, M.A.2
  • 7
    • 0014869304 scopus 로고
    • Injuries to the extensor mechanism of the hand
    • Elliot, R. A. Injuries to the extensor mechanism of the hand. Orthop. Clin. North Am. 1: 335, 1970.
    • (1970) Orthop. Clin. North Am. , vol.1 , pp. 335
    • Elliot, R.A.1
  • 8
    • 0024548857 scopus 로고
    • Early dynamic splinting for extensor tendon injuries
    • Browne, E. Z., Jr., and Ribik, C. A. Early dynamic splinting for extensor tendon injuries. J. Hand Surg. (Am.) 14: 72, 1989.
    • (1989) J. Hand Surg. (Am.) , vol.14 , pp. 72
    • Browne Jr., E.Z.1    Ribik, C.A.2
  • 9
    • 0024514356 scopus 로고
    • A comparison of results of extensor tendon repair followed by early controlled mobilisation versus static immobilisation
    • Chow, J. A., Dovelle, S., Thomes, L. J., Ho, P. K., and Saldana, J. A comparison of results of extensor tendon repair followed by early controlled mobilisation versus static immobilisation. J. Hand Surg. (Br.) 14: 18, 1989.
    • (1989) J. Hand Surg. (Br.) , vol.14 , pp. 18
    • Chow, J.A.1    Dovelle, S.2    Thomes, L.J.3    Ho, P.K.4    Saldana, J.5
  • 10
    • 0025332018 scopus 로고
    • Early controlled active mobilization with dynamic splintage for treatment of extensor tendon injuries
    • Hung, L. K., Chan, A., Chang, J., Tsang, A., and Leung, P. C. Early controlled active mobilization with dynamic splintage for treatment of extensor tendon injuries. J. Hand Surg. (Am.) 15: 251, 1990.
    • (1990) J. Hand Surg. (Am.) , vol.15 , pp. 251
    • Hung, L.K.1    Chan, A.2    Chang, J.3    Tsang, A.4    Leung, P.C.5
  • 11
    • 0026323231 scopus 로고
    • Results of acute zone III extensor tendon injuries treated with dynamic extension splinting
    • Saldana, M. J., Choban, S., Westerbeck, P., and Schacherer, T. G. Results of acute zone III extensor tendon injuries treated with dynamic extension splinting. J. Hand Surg. (Am.) 16: 1145, 1991.
    • (1991) J. Hand Surg. (Am.) , vol.16 , pp. 1145
    • Saldana, M.J.1    Choban, S.2    Westerbeck, P.3    Schacherer, T.G.4
  • 12
    • 0027932247 scopus 로고
    • Mechanical analysis of the tendon suture techniques
    • Greenwald, D. P., Hong, H. Z., and May, J. W. Mechanical analysis of the tendon suture techniques. J. Hand Surg. (Am.) 19: 641, 1994.
    • (1994) J. Hand Surg. (Am.) , vol.19 , pp. 641
    • Greenwald, D.P.1    Hong, H.Z.2    May, J.W.3
  • 13
    • 0038475141 scopus 로고
    • An analysis of factors that support early active short arc motion of the repaired central slip
    • Evans, R. B., and Thompson, D. E. An analysis of factors that support early active short arc motion of the repaired central slip. J. Hand Ther. 5: 187, 1992.
    • (1992) J. Hand Ther. , vol.5 , pp. 187
    • Evans, R.B.1    Thompson, D.E.2
  • 14
    • 0027960571 scopus 로고
    • Early active short arc motion for the repaired central slip
    • Evans, R. B. Early active short arc motion for the repaired central slip. J. Hand Surg. (Am.) 19: 991, 1994.
    • (1994) J. Hand Surg. (Am.) , vol.19 , pp. 991
    • Evans, R.B.1
  • 15
    • 0026539824 scopus 로고
    • Biomechanical characteristics of extensor tendon suture techniques
    • Newport, M. L., and Williams, C. D. Biomechanical characteristics of extensor tendon suture techniques. J. Hand Surg. (Am.) 17: 1117, 1992.
    • (1992) J. Hand Surg. (Am.) , vol.17 , pp. 1117
    • Newport, M.L.1    Williams, C.D.2
  • 16
    • 0018608594 scopus 로고
    • Early active motion following a beveled technique of flexor tendon repair: Report on fifty cases
    • Becker, H., Orak, F., and Duponselle, E. Early active motion following a beveled technique of flexor tendon repair: Report on fifty cases. J. Hand Surg. (Am.) 4: 454, 1979.
    • (1979) J. Hand Surg. (Am.) , vol.4 , pp. 454
    • Becker, H.1    Orak, F.2    Duponselle, E.3
  • 17
    • 0030924726 scopus 로고    scopus 로고
    • Optimization of the MGH repair using an algorithm for tenorrhaphy evaluation
    • Wassermann, R. J., Howard, R., Markee, B., et al. Optimization of the MGH repair using an algorithm for tenorrhaphy evaluation. Plast. Reconstr. Surg. 99: 1688, 1997.
    • (1997) Plast. Reconstr. Surg. , vol.99 , pp. 1688
    • Wassermann, R.J.1    Howard, R.2    Markee, B.3
  • 18
    • 0032745605 scopus 로고    scopus 로고
    • A comparative analysis of the six-strand double-loop flexor tendon repair and three other techniques: A human cadaveric study
    • Gill, R. S., Lim, B. H., Shatford, R. A., Toth, E., Voor, M. J., and Tsai, T. M. A comparative analysis of the six-strand double-loop flexor tendon repair and three other techniques: A human cadaveric study. J. Hand Surg. (Am.) 24: 1315, 1999.
    • (1999) J. Hand Surg. (Am.) , vol.24 , pp. 1315
    • Gill, R.S.1    Lim, B.H.2    Shatford, R.A.3    Toth, E.4    Voor, M.J.5    Tsai, T.M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.