Volumn 21, Issue 5, 2005, Pages 645-649

Combined use of the intravascular blood-pool agent, gadomer, and carbon dioxide: A novel type of double-contrast magnetic resonance angiography (MRA)

Author keywords

Artifact reduction; Blood pool agent; Carbon dioxide; Interventional MRI; MRA

Indexed keywords

CARBON DIOXIDE; GADOMER 17; KETAMINE; TELAZOL; TILETAMINE; XYLAZINE; ZOLAZEPAM;

EID: 17844387426     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/jmri.20304     Document Type: Article
Times cited : (10)

References (20)
  • 2
    • 0031884958 scopus 로고    scopus 로고
    • Remember true FISP? A high SNR, near 1-second imaging method for T2-like contrast in interventional MRI at .2T
    • Duerk JL, Lewin JS, Wendt M, Petersilge C. Remember true FISP? A high SNR, near 1-second imaging method for T2-like contrast in interventional MRI at .2T. J Magn Reson Imaging 1998;8:203-208.
    • (1998) J Magn Reson Imaging , vol.8 , pp. 203-208
    • Duerk, J.L.1    Lewin, J.S.2    Wendt, M.3    Petersilge, C.4
  • 3
    • 0033819318 scopus 로고    scopus 로고
    • The use of carbon dioxide in magnetic resonance angiography: A new type of black blood imaging
    • Maes RM, Matheijssen NA, Pattynama PM, Krestin GP. The use of carbon dioxide in magnetic resonance angiography: a new type of black blood imaging. J Magn Reson Imaging 2000;12:595-598.
    • (2000) J Magn Reson Imaging , vol.12 , pp. 595-598
    • Maes, R.M.1    Matheijssen, N.A.2    Pattynama, P.M.3    Krestin, G.P.4
  • 5
    • 0042092035 scopus 로고    scopus 로고
    • Steady-state imaging for visualisation of endovascular interventions
    • Martin AJ, Weber OM, Saeed M, Roberts TP. Steady-state imaging for visualisation of endovascular interventions. Magn Reson Med 2003;50:434-438.
    • (2003) Magn Reson Med , vol.50 , pp. 434-438
    • Martin, A.J.1    Weber, O.M.2    Saeed, M.3    Roberts, T.P.4
  • 6
    • 0344305573 scopus 로고    scopus 로고
    • Catheter-directed contrast-enhanced coronary MR angiography in swine using magnetization-prepared True-FISP
    • Green JD, Omary RA, Schirf BE, Tang R, Li D. Catheter-directed contrast-enhanced coronary MR angiography in swine using magnetization-prepared True-FISP. Magn Reson Med 2003;50:1317-1321.
    • (2003) Magn Reson Med , vol.50 , pp. 1317-1321
    • Green, J.D.1    Omary, R.A.2    Schirf, B.E.3    Tang, R.4    Li, D.5
  • 7
    • 0034330763 scopus 로고    scopus 로고
    • Determination of optimal injection parameters for intraarterial gadolinium-enhanced MR angiography
    • Frayne R, Omary RA, Unal O, Strother CM. Determination of optimal injection parameters for intraarterial gadolinium-enhanced MR angiography. J Vasc Interv Radiol 2000;11:1277-1284.
    • (2000) J Vasc Interv Radiol , vol.11 , pp. 1277-1284
    • Frayne, R.1    Omary, R.A.2    Unal, O.3    Strother, C.M.4
  • 8
    • 0035157985 scopus 로고    scopus 로고
    • Passive tracking of catheters and guidewires by contrast-enhanced MR fluoroscopy
    • Bakker CJ, Bos C, Weinmann HJ. Passive tracking of catheters and guidewires by contrast-enhanced MR fluoroscopy. Magn Reson Med 2001;45:17-23.
    • (2001) Magn Reson Med , vol.45 , pp. 17-23
    • Bakker, C.J.1    Bos, C.2    Weinmann, H.J.3
  • 9
    • 0032804898 scopus 로고    scopus 로고
    • Intraarterial gadolinium-enhanced 2D and 3D MR angiography: A preliminary study
    • Omary RA, Frayne R, Unal O, Grist TM, Strother CM. Intraarterial gadolinium-enhanced 2D and 3D MR angiography: a preliminary study. J Vasc Interv Radiol 1999;10:1315-1321.
    • (1999) J Vasc Interv Radiol , vol.10 , pp. 1315-1321
    • Omary, R.A.1    Frayne, R.2    Unal, O.3    Grist, T.M.4    Strother, C.M.5
  • 10
    • 0037254038 scopus 로고    scopus 로고
    • Two- and three-dimensional MR coronary angiography with intraarterial injections of contrast agent in dogs: A feasibility study
    • Green JD, Omary RA, Finn JP, et al. Two- and three-dimensional MR coronary angiography with intraarterial injections of contrast agent in dogs: a feasibility study Radiology 2003;226:272-277.
    • (2003) Radiology , vol.226 , pp. 272-277
    • Green, J.D.1    Omary, R.A.2    Finn, J.P.3
  • 11
    • 18244378253 scopus 로고    scopus 로고
    • Validation of injection parameters for catheter-directed intraarterial gadolinium-enhanced MR angiography
    • Omary RA, Hanseler KP, Unal O, et al. Validation of injection parameters for catheter-directed intraarterial gadolinium-enhanced MR angiography. Acad Radiol 2002;9:172-185.
    • (2002) Acad Radiol , vol.9 , pp. 172-185
    • Omary, R.A.1    Kp, H.2    Unal, O.3
  • 12
    • 0036136310 scopus 로고    scopus 로고
    • Comparison of intraarterial and IV gadolinium-enhanced MR angiography with digital subtraction angiography for the detection of renal artery stenosis in pigs
    • Omary RA, Henseler KP, Unal O, et al. Comparison of intraarterial and IV gadolinium-enhanced MR angiography with digital subtraction angiography for the detection of renal artery stenosis in pigs. AJR Am J Roentgenol 2002;178:119-123.
    • (2002) AJR Am J Roentgenol , vol.178 , pp. 119-123
    • Omary, R.A.1    Henseler, K.P.2    Unal, O.3
  • 13
    • 0036134437 scopus 로고    scopus 로고
    • Minimizing contrast agent dose during intraarterial gadolinium-enhanced MR angiography: In vitro assessment
    • Hwang KP, Green JD, Li D, et al. Minimizing contrast agent dose during intraarterial gadolinium-enhanced MR angiography: in vitro assessment. J Magn Reson Imaging 2002;15:55-61.
    • (2002) J Magn Reson Imaging , vol.15 , pp. 55-61
    • Hwang, K.P.1    Green, J.D.2    Li, D.3
  • 14
    • 0036237985 scopus 로고    scopus 로고
    • Are gadolinium-based agents really safer than iodinated agents for DSA in azotemic patients?
    • discussion 328-329
    • Nyman U, Elmsthal B, Leander P, Nilsson M, Golma K, Almen T. Are gadolinium-based agents really safer than iodinated agents for DSA in azotemic patients? Radiology 2002;223:311-318 [discussion 328-329].
    • (2002) Radiology , vol.223 , pp. 311-318
    • Nyman, U.1    Elmsthal, B.2    Leander, P.3    Nilsson, M.4    Golma, K.5    Almen, T.6
  • 15
    • 0031607344 scopus 로고    scopus 로고
    • 2) digital subtraction angiography: 26-Year experience at the University of Florida
    • 2) digital subtraction angiography: 26-year experience at the University of Florida. Eur Radiol 1998;8:391-402.
    • (1998) Eur Radiol , vol.8 , pp. 391-402
    • Hawkins, I.F.1    Caridi, J.G.2
  • 16
    • 0031738921 scopus 로고    scopus 로고
    • Carbon dioxide as a contrast agent to guide vascular interventional procedures
    • Eschelman DJ, Sullivan KL, Bonn J, Gardiner GAJ. Carbon dioxide as a contrast agent to guide vascular interventional procedures. AJR Am J Roentgenol 1998;171:1265-1270.
    • (1998) AJR Am J Roentgenol , vol.171 , pp. 1265-1270
    • Eschelman, D.J.1    Sullivan, K.L.2    Bonn, J.3    Gardiner, G.A.J.4
  • 17
    • 0028967864 scopus 로고
    • Carbon dioxide digital subtraction angiography: Expanding applications and technical evolution
    • Kerns SR, Hawkins IFJ. Carbon dioxide digital subtraction angiography: expanding applications and technical evolution. AJR Am J Roentgenol 1995;164:735-741.
    • (1995) AJR Am J Roentgenol , vol.164 , pp. 735-741
    • Kerns, S.R.1    Hawkins, I.F.J.2
  • 18
    • 0036835513 scopus 로고    scopus 로고
    • Carbon-dioxide-guided vascular interventions: Technique and pitfalls
    • Kessel DO, Robertson I, Patel J, et al. Carbon-dioxide-guided vascular interventions: technique and pitfalls. Cardiovasc Intervent Radiol 2002;25:476-483.
    • (2002) Cardiovasc Intervent Radiol , vol.25 , pp. 476-483
    • Kessel, D.O.1    Robertson, I.2    Patel, J.3
  • 20
    • 0036785022 scopus 로고    scopus 로고
    • Neurotoxicity of angiographic carbon dioxide in the cerebral vasculature
    • Wilson AJ, Boxer MM. Neurotoxicity of angiographic carbon dioxide in the cerebral vasculature. Invest Radiol 2002;37:542-551.
    • (2002) Invest Radiol , vol.37 , pp. 542-551
    • Wilson, A.J.1    Boxer, M.M.2