메뉴 건너뛰기




Volumn 21, Issue 5, 2005, Pages 596-603

Whole-body MR angiography using a novel 32-receiving-channel MR system with surface coil technology: First clinical experience

Author keywords

Atherosclerosis; Magnetic resonance (MR); MR angiography; MR imaging; MR technology

Indexed keywords

GADOLINIUM PENTETATE;

EID: 17844368652     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/jmri.20303     Document Type: Article
Times cited : (38)

References (25)
  • 1
    • 0003775050 scopus 로고    scopus 로고
    • Dallas: American Heart Association
    • American Heart Association. 2004 Heart and stroke statistical update. Dallas: American Heart Association 2003.
    • (2003) 2004 Heart and Stroke Statistical Update
  • 2
    • 0038275856 scopus 로고    scopus 로고
    • Preoperative evaluation of carotid artery stenosis: Comparison of contrast-enhanced MR angiography and duplex sonography with digital subtraction angiography
    • Borisch I, Horn M, Butz B, et al. Preoperative evaluation of carotid artery stenosis: comparison of contrast-enhanced MR angiography and duplex sonography with digital subtraction angiography. Am J Neuroradiol 2003;24:1117-1122.
    • (2003) Am J Neuroradiol , vol.24 , pp. 1117-1122
    • Borisch, I.1    Horn, M.2    Butz, B.3
  • 3
    • 0344153034 scopus 로고    scopus 로고
    • Proximal great vessels of aortic arch: Comparison of three-dimensional gadolinium-enhanced MR angiography and digital subtraction angiography
    • Randoux B, Marro B, Koskas F, Chiras J, Dormont D, Marsault C. Proximal great vessels of aortic arch: comparison of three-dimensional gadolinium-enhanced MR angiography and digital subtraction angiography. Radiology 2003;229:697-702.
    • (2003) Radiology , vol.229 , pp. 697-702
    • Randoux, B.1    Marro, B.2    Koskas, F.3    Chiras, J.4    Dormont, D.5    Marsault, C.6
  • 4
    • 0034969330 scopus 로고    scopus 로고
    • Carotid artery stenosis: Prospective comparison of CT, three-dimensional gadolinium-enhanced MR, and conventional angiography
    • Randoux B, Marro B, Koskas F, et al. Carotid artery stenosis: prospective comparison of CT, three-dimensional gadolinium-enhanced MR, and conventional angiography. Radiology 2001;220: 179-185.
    • (2001) Radiology , vol.220 , pp. 179-185
    • Randoux, B.1    Marro, B.2    Koskas, F.3
  • 5
    • 0033956696 scopus 로고    scopus 로고
    • Renal arterial stenosis: Prospective comparison of color Doppler US and breath-hold, three-dimensional, dynamic, gadolinium-enhanced MR angiography
    • De Cobelli F, Venturini M, Vanzulli A, et al. Renal arterial stenosis: prospective comparison of color Doppler US and breath-hold, three-dimensional, dynamic, gadolinium-enhanced MR angiography. Radiology 2000;214:373-380.
    • (2000) Radiology , vol.214 , pp. 373-380
    • De Cobelli, F.1    Venturini, M.2    Vanzulli, A.3
  • 7
    • 0036891772 scopus 로고    scopus 로고
    • Gadobenate dimeglumine-enhanced MR angiography of the abdominal aorta and renal arteries
    • Kroencke TJ, Wasser MN, Pattynama PMT, et al. Gadobenate dimeglumine-enhanced MR angiography of the abdominal aorta and renal arteries. AJR Am J Roentgenol 2002;179:1573-1582.
    • (2002) AJR Am J Roentgenol , vol.179 , pp. 1573-1582
    • Kroencke, T.J.1    Wasser, M.N.2    Pattynama, P.M.T.3
  • 8
    • 0034757726 scopus 로고    scopus 로고
    • 0.5 M Gd chelate (Magnevist) versus 1.0 M Gd chelate (Gadovist): Dose-independent effect on image quality of pelvic three-dimensional MR-angiography
    • Goyen M, Lauenstein TC, Herborn CU, Debatin JF, Bosk S, Ruehm SG. 0.5 M Gd chelate (Magnevist) versus 1.0 M Gd chelate (Gadovist): dose-independent effect on image quality of pelvic three-dimensional MR-angiography. J Magn Reson Imaging 2001; 14:602-607.
    • (2001) J Magn Reson Imaging , vol.14 , pp. 602-607
    • Goyen, M.1    Lauenstein, T.C.2    Herborn, C.U.3    Debatin, J.F.4    Bosk, S.5    Ruehm, S.G.6
  • 11
  • 12
    • 0036085258 scopus 로고    scopus 로고
    • Whole-body three-dimensional MR angiography with a rolling table platform: Initial clinical experience
    • Goyen M, Quick HH, Debatin JF, et al. Whole-body three-dimensional MR angiography with a rolling table platform: initial clinical experience. Radiology 2002;224:270-277.
    • (2002) Radiology , vol.224 , pp. 270-277
    • Goyen, M.1    Quick, H.H.2    Debatin, J.F.3
  • 14
    • 0036158390 scopus 로고    scopus 로고
    • Continuously moving table data acquisition method for long FOV contrast-enhanced MRA and whole-body MRI
    • Kruger DG, Riederer SJ, Grimm RC, Rossman PJ. Continuously moving table data acquisition method for long FOV contrast-enhanced MRA and whole-body MRI. Magn Reson Med 2002;47:224-231.
    • (2002) Magn Reson Med , vol.47 , pp. 224-231
    • Kruger, D.G.1    Riederer, S.J.2    Grimm, R.C.3    Rossman, P.J.4
  • 15
    • 0035820272 scopus 로고    scopus 로고
    • Rapid magnetic resonance angiography for detection of atherosclerosis
    • Ruehm SG, Goyen M, Barkhausen J, et al. Rapid magnetic resonance angiography for detection of atherosclerosis. Lancet 2001; 357:1086-1091.
    • (2001) Lancet , vol.357 , pp. 1086-1091
    • Ruehm, S.G.1    Goyen, M.2    Barkhausen, J.3
  • 16
    • 0029336482 scopus 로고
    • Nonlinear excitation profiles for three-dimensional inflow MR angiography
    • Nagele T, Klose U, Grodd W, Nusslin F, Voigt K. Nonlinear excitation profiles for three-dimensional inflow MR angiography. J Magn Reson Imaging 1995;5:416-420.
    • (1995) J Magn Reson Imaging , vol.5 , pp. 416-420
    • Nagele, T.1    Klose, U.2    Grodd, W.3    Nusslin, F.4    Voigt, K.5
  • 18
    • 0036235996 scopus 로고    scopus 로고
    • Optimization of contrast dosage for gadobenate dimeglumine-enhanced high-resolution whole-body 3D magnetic resonance angiography
    • Goyen M, Herborn CU, Lauenstein TC, et al. Optimization of contrast dosage for gadobenate dimeglumine-enhanced high-resolution whole-body 3D magnetic resonance angiography. Invest Radiol 2002;37:263-268.
    • (2002) Invest Radiol , vol.37 , pp. 263-268
    • Goyen, M.1    Herborn, C.U.2    Lauenstein, T.C.3
  • 19
    • 0031906175 scopus 로고    scopus 로고
    • Test bolus examination in the carotid artery at dynamic gadolinium-enhanced MR angiography
    • Kim JK, Fab RI, Wright GA. Test bolus examination in the carotid artery at dynamic gadolinium-enhanced MR angiography. Radiology 1998;206:283-289.
    • (1998) Radiology , vol.206 , pp. 283-289
    • Kim, J.K.1    Fab, R.I.2    Wright, G.A.3
  • 20
    • 0034758005 scopus 로고    scopus 로고
    • Kinetic evaluation of an i.v. bolus of MR contrast media
    • Heverhagen JT, Funck RC, Schwarz U, et al. Kinetic evaluation of an i.v. bolus of MR contrast media. Magn Reson Imaging 2001;19: 1025-1030.
    • (2001) Magn Reson Imaging , vol.19 , pp. 1025-1030
    • Heverhagen, J.T.1    Funck, R.C.2    Schwarz, U.3
  • 21
    • 0037380525 scopus 로고    scopus 로고
    • Detection of atherosclerosis: Systemic imaging for systemic disease with whole-body three-dimensional MR angiography - Initial experience
    • Goyen M, Herbom CU, Kröger K, Lauenstein TC, Debatin JF, Ruehm SG. Detection of atherosclerosis: systemic imaging for systemic disease with whole-body three-dimensional MR angiography - initial experience. Radiology 2003;227:277-282.
    • (2003) Radiology , vol.227 , pp. 277-282
    • Goyen, M.1    Herbom, C.U.2    Kröger, K.3    Lauenstein, T.C.4    Debatin, J.F.5    Ruehm, S.G.6
  • 22
    • 0038343488 scopus 로고    scopus 로고
    • Contrast-enhanced three-dimensional MR angiography of neck vessels: Does dephasing effect alter diagnostic accuracy?
    • Cosottini M, Calabrese R, Puglioli M, et al. Contrast-enhanced three-dimensional MR angiography of neck vessels: does dephasing effect alter diagnostic accuracy? Eur Radiol 2003;13:571-581.
    • (2003) Eur Radiol , vol.13 , pp. 571-581
    • Cosottini, M.1    Calabrese, R.2    Puglioli, M.3
  • 23
    • 0030878026 scopus 로고    scopus 로고
    • Screening for concomitant diseases in peripheral vascular patients. Results of a systematic approach
    • von Kemp K, van den Brande P, Peterson T, et al. Screening for concomitant diseases in peripheral vascular patients. Results of a systematic approach. Int Angiol 1997;16:114-122.
    • (1997) Int Angiol , vol.16 , pp. 114-122
    • Von Kemp, K.1    Van Den Brande, P.2    Peterson, T.3
  • 24
    • 0033003013 scopus 로고    scopus 로고
    • Lower-extremity arteriosclerosis as a reflection of a systemic process: Implications for concomitant coronary and carotid disease
    • Dormandy J, Heeck L, Vig S. Lower-extremity arteriosclerosis as a reflection of a systemic process: implications for concomitant coronary and carotid disease. Semin Vasc Surg 1999;12:118-122.
    • (1999) Semin Vasc Surg , vol.12 , pp. 118-122
    • Dormandy, J.1    Heeck, L.2    Vig, S.3
  • 25
    • 0033861916 scopus 로고    scopus 로고
    • Arterial pseudostenosis on first-pass gadolinium-enhanced three-dimensional MR angiography: New observation of a potential pitfall
    • Chiowanich P, Mitchell DG, Ortega HV, Mohamed F. Arterial pseudostenosis on first-pass gadolinium-enhanced three-dimensional MR angiography: new observation of a potential pitfall. AJR Am J Roentgenol 2000;175:523-527.
    • (2000) AJR Am J Roentgenol , vol.175 , pp. 523-527
    • Chiowanich, P.1    Mitchell, D.G.2    Ortega, H.V.3    Mohamed, F.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.