메뉴 건너뛰기




Volumn 27, Issue 5, 2005, Pages 876-881

First clinical results with a 30° end-to-side coronary anastomosis coupler

Author keywords

Coronary artery bypass surgery; Facilitated anastomosis; Mechanical connector; Revascularization; Sutureless anastomotic device

Indexed keywords

NITINOL;

EID: 17844365024     PISSN: 10107940     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ejcts.2004.12.065     Document Type: Conference Paper
Times cited : (9)

References (20)
  • 3
    • 0035515444 scopus 로고    scopus 로고
    • Coronary artery bypass-grafting using interrupted anastomosis with the U-clip
    • H. Niinami, Y. Takeuchi, S. Ichikawa, T. Ban, R. Higashita, Y. Suda, and S. Suzuki Coronary artery bypass-grafting using interrupted anastomosis with the U-clip Kyobu Geka 54 12 2001 1003 1006
    • (2001) Kyobu Geka , vol.54 , Issue.12 , pp. 1003-1006
    • Niinami, H.1    Takeuchi, Y.2    Ichikawa, S.3    Ban, T.4    Higashita, R.5    Suda, Y.6    Suzuki, S.7
  • 5
    • 0033858145 scopus 로고    scopus 로고
    • Sutureless coronary artery bypass with biologic glued anastomoses: Preliminary in vivo and in vitro results
    • S.R. Gundry, K. Black, and H. Izutani Sutureless coronary artery bypass with biologic glued anastomoses: preliminary in vivo and in vitro results J Thorac Cardiovasc Surg 120 3 2000 473 477
    • (2000) J Thorac Cardiovasc Surg , vol.120 , Issue.3 , pp. 473-477
    • Gundry, S.R.1    Black, K.2    Izutani, H.3
  • 6
    • 2642584943 scopus 로고    scopus 로고
    • Clinical and angiographic results after mechanical connection for distal anastomosis in coronary surgery
    • T. Carrel, L. Englberger, D. Keller, S. Windecker, B. Meier, and F. Eckstein Clinical and angiographic results after mechanical connection for distal anastomosis in coronary surgery J Thorac Cardiovasc Surg 127 2004 1632 1640
    • (2004) J Thorac Cardiovasc Surg , vol.127 , pp. 1632-1640
    • Carrel, T.1    Englberger, L.2    Keller, D.3    Windecker, S.4    Meier, B.5    Eckstein, F.6
  • 9
    • 0036959930 scopus 로고    scopus 로고
    • Clinical experience with the cor link device for proximal anastomosis of the saphenous vein to the aorta: A clinical, prospective, and randomized study
    • F.C. Riess, H. Helmold, I. Hilfer, R. Bader, J. Stripling, C. Loewer, F. Wesner, and N. Bleese Clinical experience with the cor link device for proximal anastomosis of the saphenous vein to the aorta: a clinical, prospective, and randomized study Heart Surg Forum 5 2002 345 353
    • (2002) Heart Surg Forum , vol.5 , pp. 345-353
    • Riess, F.C.1    Helmold, H.2    Hilfer, I.3    Bader, R.4    Stripling, J.5    Loewer, C.6    Wesner, F.7    Bleese, N.8
  • 10
    • 2342432452 scopus 로고    scopus 로고
    • Early quantitative coronary angiography of saphenous vein grafts for coronary artery bypass grafting harvested by means of open versus endoscopic saphenectomy: A prospective randomized trial
    • L.P. Perrault, H. Jeanmart, L. Bilodeau, J. Lesperance, J.F. Tanguay, D. Bouchard, P. Page, and M. Carrier Early quantitative coronary angiography of saphenous vein grafts for coronary artery bypass grafting harvested by means of open versus endoscopic saphenectomy: a prospective randomized trial J Thorac Cardiovasc Surg 127 2004 1402 1407
    • (2004) J Thorac Cardiovasc Surg , vol.127 , pp. 1402-1407
    • Perrault, L.P.1    Jeanmart, H.2    Bilodeau, L.3    Lesperance, J.4    Tanguay, J.F.5    Bouchard, D.6    Page, P.7    Carrier, M.8
  • 13
    • 0030245599 scopus 로고    scopus 로고
    • Coronary bypass graft fate and patient outcome angiographic follow-up of 5065 grafts related to survival and reoperation in 1488 patients during 25 years
    • G.M. Fitzgibbon, H.P. Kafka, A.J. Leach, W.J. Keon, G.D. Hooper, and J.R. Burton Coronary bypass graft fate and patient outcome angiographic follow-up of 5065 grafts related to survival and reoperation in 1488 patients during 25 years J Am Coll Cardiol 28 1996 616 626
    • (1996) J Am Coll Cardiol , vol.28 , pp. 616-626
    • Fitzgibbon, G.M.1    Kafka, H.P.2    Leach, A.J.3    Keon, W.J.4    Hooper, G.D.5    Burton, J.R.6
  • 14
    • 0034842174 scopus 로고    scopus 로고
    • Off-pump coronary artery bypass may decrease the patency of saphenous vein grafts
    • K.B. Kim, C. Lim, I.H. Chae, B.H. Oh, M.M. Lee, and Y.B. Park Off-pump coronary artery bypass may decrease the patency of saphenous vein grafts Ann Thorac Surg 72 2001 S1033 S1037
    • (2001) Ann Thorac Surg , vol.72
    • Kim, K.B.1    Lim, C.2    Chae, I.H.3    Oh, B.H.4    Lee, M.M.5    Park, Y.B.6
  • 15
    • 1442285894 scopus 로고    scopus 로고
    • Patencies of 2127 arterial to coronary conduits over 15 years
    • J. Tatoulis, B.F. Buxton, and J.A. Fuller Patencies of 2127 arterial to coronary conduits over 15 years Ann Thorac Surg 77 2004 93 101
    • (2004) Ann Thorac Surg , vol.77 , pp. 93-101
    • Tatoulis, J.1    Buxton, B.F.2    Fuller, J.A.3
  • 16
    • 0042343776 scopus 로고    scopus 로고
    • Coronary anastomosis devices: Blood-exposed non-intimal surface and coronary wall stress
    • J.S. Scheltes, C.J. van Andel, P.V. Pistecky, and C. Borst Coronary anastomosis devices: blood-exposed non-intimal surface and coronary wall stress J Thorac Cardiovasc Surg 126 2003 191 199
    • (2003) J Thorac Cardiovasc Surg , vol.126 , pp. 191-199
    • Scheltes, J.S.1    Van Andel, C.J.2    Pistecky, P.V.3    Borst, C.4
  • 17
    • 1442324622 scopus 로고    scopus 로고
    • Clinical experiences with devices for facilitated anastomoses in coronary artey bypass surgery
    • T.P. Carrel, F.S. Eckstein, L. Englberger, P.A. Berdat, and J. Schmidli Clinical experiences with devices for facilitated anastomoses in coronary artey bypass surgery Ann Thorac Surg 77 2004 1110 1120
    • (2004) Ann Thorac Surg , vol.77 , pp. 1110-1120
    • Carrel, T.P.1    Eckstein, F.S.2    Englberger, L.3    Berdat, P.A.4    Schmidli, J.5
  • 18
    • 0028246280 scopus 로고
    • Influence of angle on wall shear stress distribution for an end-to-side anastomosis
    • M. Ojha, R.S. Cobbold, and K.W. Johnston Influence of angle on wall shear stress distribution for an end-to-side anastomosis J Vasc Surg 19 1994 1067 1073
    • (1994) J Vasc Surg , vol.19 , pp. 1067-1073
    • Ojha, M.1    Cobbold, R.S.2    Johnston, K.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.