Volumn 162-163, Issue SPEC. ISS., 2005, Pages 163-168

Influence of the anodic oxidation on the physicochemical properties of the Ti6Al4V ELI alloy

Author keywords

AFM; Chemiluminescence method; Corrosion resistance investigation; Implants; Passive layers; Titanium alloy; XPS

Indexed keywords

ALUMINUM; ANODIC OXIDATION; ATOMIC FORCE MICROSCOPY; CHEMILUMINESCENCE; CORROSION RESISTANCE; PASSIVATION; VANADIUM; X RAY PHOTOELECTRON SPECTROSCOPY; ALLOYS; CERIUM ALLOYS; DENTAL PROSTHESES; ELECTROLYTIC POLISHING; TITANIUM ALLOYS;

EID: 17844364240     PISSN: 09240136     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jmatprotec.2005.02.203     Document Type: Conference Paper
Times cited : (35)

References (14)
  • 1
    • 0022991740 scopus 로고
    • Electrochemical behavior of titanium and titanium alloys with respect to their use as surgical implant materials
    • P. Christel A. Meunier A.J.C. Lee Elsevier Amsterdam
    • J.P. Simpson Electrochemical behavior of titanium and titanium alloys with respect to their use as surgical implant materials P. Christel A. Meunier A.J.C. Lee Biomedical and Biomechanical Performance of Biomaterials 1986 Elsevier Amsterdam 63 68
    • (1986) Biomedical and Biomechanical Performance of Biomaterials , pp. 63-68
    • Simpson, J.P.1
  • 3
    • 0346282876 scopus 로고    scopus 로고
    • Wydawnictwo Politechniki Śla̧skiej Poland, Gliwice
    • J. Marciniak Biomaterials 2002 Wydawnictwo Politechniki Śla̧skiej Poland, Gliwice
    • (2002) Biomaterials
    • Marciniak, J.1
  • 13
    • 17844372922 scopus 로고    scopus 로고
    • ASTM F-746-81
    • ASTM F-746-81.
  • 14
    • 17844366772 scopus 로고    scopus 로고
    • ASTM G-5
    • ASTM G-5.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.