메뉴 건너뛰기




Volumn 26, Issue 6, 1997, Pages 973-980

Transcranial Doppler monitoring during carotid endarterectomy: Is it appropriate for selecting patients in need of a shunt?

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTERIOGRAPHY; ARTERY CLAMP; ARTICLE; CAROTID ARTERY OBSTRUCTION; CAROTID ENDARTERECTOMY; CLINICAL TRIAL; DOPPLER ECHOGRAPHY; FEMALE; FLOW RATE; HUMAN; ISCHEMIA; MAJOR CLINICAL STUDY; MALE; MORBIDITY; PATIENT MONITORING; PATIENT SELECTION; PRESSURE MEASUREMENT; PRIORITY JOURNAL; SHUNTING;

EID: 17744404926     PISSN: 07415214     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0741-5214(97)70009-0     Document Type: Article
Times cited : (64)

References (22)
  • 2
    • 85119466046 scopus 로고    scopus 로고
    • The role of routine or selective carotid artery shunting during carotid endarterectomy and the different methods of monitoring in selective shunting
    • C Counsell R Salinas R Naylor C. Warlow The role of routine or selective carotid artery shunting during carotid endarterectomy and the different methods of monitoring in selective shunting C Warlow J Van Gijn P Sandercock L Candelise P Langhorne Stroke module of the Cochrane database of systematic reviews 1997 [updated 03 June 1997]. Available in The Cochrane Library [database on disk and CDROM]. The Cochrane Collaboration; Issue 3. Oxford: Update Software Updated quarterly
    • (1997)
    • Counsell, C1    Salinas, R2    Naylor, R3    Warlow, C.4
  • 3
    • 0020394689 scopus 로고
    • Noninvasive transcranial Doppler ultrasound recording of flow velocity in the basal cerebral arteries
    • R Aaslid TM Markwalder H Nornes Noninvasive transcranial Doppler ultrasound recording of flow velocity in the basal cerebral arteries J Neurosurg 57 1982 769 774
    • (1982) J Neurosurg , vol.57 , pp. 769-774
    • Aaslid, R1    Markwalder, TM2    Nornes, H3
  • 4
    • 0026453498 scopus 로고
    • Risk and benefits of shunting in carotid endarterectomy
    • JH. Halsey Risk and benefits of shunting in carotid endarterectomy Stroke 23 1992 1583 1587
    • (1992) Stroke , vol.23 , pp. 1583-1587
    • Halsey, JH.1
  • 5
    • 0026709136 scopus 로고
    • Relation between middle cerebral artery blood flow velocity and stump pressure during carotid endarterectomy
    • MP Spencer GI Thomas MA. Moehring Relation between middle cerebral artery blood flow velocity and stump pressure during carotid endarterectomy Stroke 23 1992 1439 1445
    • (1992) Stroke , vol.23 , pp. 1439-1445
    • Spencer, MP1    Thomas, GI2    Moehring, MA.3
  • 6
    • 0014635978 scopus 로고
    • Carotid artery back pressure: a test of cerebral tolerance to temporary carotid occlusion
    • WS Moore AD. Hall Carotid artery back pressure: a test of cerebral tolerance to temporary carotid occlusion Arch Surg 99 1969 702 710
    • (1969) Arch Surg , vol.99 , pp. 702-710
    • Moore, WS1    Hall, AD.2
  • 8
    • 0029163415 scopus 로고
    • Stump pressure, electroencephalographic changes and the contralateral carotid artery: another look at selective shunting
    • RN Harada AJ Comerota GM Good HA Hashemi JF Hulihan Stump pressure, electroencephalographic changes and the contralateral carotid artery: another look at selective shunting Am J Surg 170 1995 148 153
    • (1995) Am J Surg , vol.170 , pp. 148-153
    • Harada, RN1    Comerota, AJ2    Good, GM3    Hashemi, HA4    Hulihan, JF5
  • 9
    • 0025986370 scopus 로고
    • Monitoring electrophysiologic function during electroencephalogram
    • AM Lam PH Manninen GG Ferguson W. Nantau Monitoring electrophysiologic function during electroencephalogram Anesthesiology 75 1991 15 21
    • (1991) Anesthesiology , vol.75 , pp. 15-21
    • Lam, AM1    Manninen, PH2    Ferguson, GG3    Nantau, W.4
  • 10
    • 0020674566 scopus 로고
    • The ischemic tolerance of neural tissue and the need for monitoring and selective shunting during carotid endarterectomy
    • TM. Sundt The ischemic tolerance of neural tissue and the need for monitoring and selective shunting during carotid endarterectomy Stroke 14 1983 93 98
    • (1983) Stroke , vol.14 , pp. 93-98
    • Sundt, TM.1
  • 11
    • 0030070212 scopus 로고    scopus 로고
    • Cerebral oximetry in patients undergoing carotid endarterectomy under regional anesthesia
    • SK Samra P Dorje GB Zelenock JC. Stanley Cerebral oximetry in patients undergoing carotid endarterectomy under regional anesthesia Stroke 27 1996 49 55
    • (1996) Stroke , vol.27 , pp. 49-55
    • Samra, SK1    Dorje, P2    Zelenock, GB3    Stanley, JC.4
  • 12
    • 0016215281 scopus 로고
    • Carotid artery back pressure and endarterectomy under regional anesthesia
    • RW Hobson BW Creighton JW Sublett CW Fedde NM. Rich Carotid artery back pressure and endarterectomy under regional anesthesia Arch Surg 109 1974 682 687
    • (1974) Arch Surg , vol.109 , pp. 682-687
    • Hobson, RW1    Creighton, BW2    Sublett, JW3    Fedde, CW4    Rich, NM.5
  • 13
    • 0023858355 scopus 로고
    • Carotid endarterectomy with local anesthesia: results and advantages
    • CD Hafner WE. Evans Carotid endarterectomy with local anesthesia: results and advantages J Vasc Surg 7 1988 232 239
    • (1988) J Vasc Surg , vol.7 , pp. 232-239
    • Hafner, CD1    Evans, WE.2
  • 15
    • 0001448975 scopus 로고
    • Deciding whether your treatment has done harm
    • DL Sackett RB Haynes P. Tugwell Deciding whether your treatment has done harm DL Sackett RB Haynes P Tugwell Clinical epidemiology. 1985 Little, Brown, and Company Boston 227 232
    • (1985) , pp. 227-232
    • Sackett, DL1    Haynes, RB2    Tugwell, P.3
  • 16
    • 0029976927 scopus 로고    scopus 로고
    • Is transcranial Doppler effective in avoiding the hazards of carotid surgery?
    • NM Bornstein GB Rossi TA Treves EG. Shifrin Is transcranial Doppler effective in avoiding the hazards of carotid surgery? Cardiovasc Surg 4 1996 335 337
    • (1996) Cardiovasc Surg , vol.4 , pp. 335-337
    • Bornstein, NM1    Rossi, GB2    Treves, TA3    Shifrin, EG.4
  • 17
    • 0028235279 scopus 로고
    • Comparison of measurement of stump pressure and transcranial measurement of flow velocity in the middle cerebral artery in carotid surgery
    • M Kalra H Al-Khaffaf A Farrell WA Wallbank D. Charlesworth Comparison of measurement of stump pressure and transcranial measurement of flow velocity in the middle cerebral artery in carotid surgery Ann Vasc Surg 8 1994 224 231
    • (1994) Ann Vasc Surg , vol.8 , pp. 224-231
    • Kalra, M1    Al-Khaffaf, H2    Farrell, A3    Wallbank, WA4    Charlesworth, D.5
  • 18
    • 0026318552 scopus 로고
    • Stroke prevention during carotid surgery in high risk patients (value of transcranial Doppler and local anesthesia)
    • P Bergeron H Benichou P Rudondy JM Jausseran M Ferdani R Courbier Stroke prevention during carotid surgery in high risk patients (value of transcranial Doppler and local anesthesia) J Cardiovasc Surg (Torino) 32 1991 713 719
    • (1991) J Cardiovasc Surg (Torino) , vol.32 , pp. 713-719
    • Bergeron, P1    Benichou, H2    Rudondy, P3    Jausseran, JM4    Ferdani, M5    Courbier, R6
  • 19
    • 0020037976 scopus 로고
    • The accuracy of carotid back pressure as an index for shunt requirements
    • GC Hunter G Sieffert JM Malone WS. Moore The accuracy of carotid back pressure as an index for shunt requirements Stroke 13 1982 319 326
    • (1982) Stroke , vol.13 , pp. 319-326
    • Hunter, GC1    Sieffert, G2    Malone, JM3    Moore, WS.4
  • 20
    • 0018956806 scopus 로고
    • Relationship of intraoperative EEG monitoring and stump pressure measurements during carotid endarterectomy
    • DC Brewster PJ O'Hara C Darling JW Hallett Jr. Relationship of intraoperative EEG monitoring and stump pressure measurements during carotid endarterectomy Circulation 62 suppl 1 1980 1 7
    • (1980) Circulation , vol.62 , Issue.suppl 1 , pp. 1-7
    • Brewster, DC1    O'Hara, PJ2    Darling, C3    Hallett, JW4
  • 21
    • 0025904226 scopus 로고
    • Technique and clinical results of carotid stump back-pressure to determine selective shunting during carotid endarterectomy
    • JP Archie Jr. Technique and clinical results of carotid stump back-pressure to determine selective shunting during carotid endarterectomy J Vasc Surg 13 1991 319 327
    • (1991) J Vasc Surg , vol.13 , pp. 319-327
    • Archie, JP1
  • 22
    • 0029817888 scopus 로고    scopus 로고
    • Carotid endarterectomy: lessons from intraoperative monitoring—a decade of experience
    • WJ McCarthy AE Park E Koushanpour WH Pearce JST Yao Carotid endarterectomy: lessons from intraoperative monitoring—a decade of experience Ann Surg 224 1996 297 307
    • (1996) Ann Surg , vol.224 , pp. 297-307
    • McCarthy, WJ1    Park, AE2    Koushanpour, E3    Pearce, WH4    Yao, JST5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.