메뉴 건너뛰기




Volumn 20, Issue 2 II, 2005, Pages 1291-1298

A busbar differential protection relay suitable for use with measurement type current transformers

Author keywords

Blocking signal and remanent flux; Busbar protection; Current transformer saturation; Difference function; Measurement CT

Indexed keywords

ALGORITHMS; DIGITAL SIGNAL PROCESSING; ELECTRIC CURRENT MEASUREMENT; ELECTRIC EQUIPMENT PROTECTION; ELECTRIC FAULT CURRENTS; ELECTRIC INSTRUMENT TRANSFORMERS; ELECTRIC RELAYS;

EID: 17744382000     PISSN: 08858977     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPWRD.2004.834325     Document Type: Article
Times cited : (35)

References (9)
  • 1
    • 0001573323 scopus 로고
    • "Harmonic-current-restrained relays for differential protection"
    • L. F. Kennedy and C. D. Hayward, "Harmonic-current-restrained relays for differential protection," AIEE Trans., vol. 57, pp. 262-266, 1938.
    • (1938) AIEE Trans. , vol.57 , pp. 262-266
    • Kennedy, L.F.1    Hayward, C.D.2
  • 2
    • 0024862710 scopus 로고
    • "Low impedance biased differential busbar protection for application to busbars of widely differing configuration"
    • Apr
    • J. B. Royle and A. Hill, "Low impedance biased differential busbar protection for application to busbars of widely differing configuration," in Proc. IEE 4th Int. Conf. Developments in Power System Protection, Apr. 1989, pp. 40-43.
    • (1989) Proc. IEE 4th Int. Conf. Developments in Power System Protection , pp. 40-43
    • Royle, J.B.1    Hill, A.2
  • 4
    • 84897411075 scopus 로고
    • "Digital bus-zone protection"
    • A. Kumar and P. Hansen, "Digital bus-zone protection," IEEE Comput. Applicat. Power, vol. 6, no. 4, pp. 29-34, 1993.
    • (1993) IEEE Comput. Applicat. Power , vol.6 , Issue.4 , pp. 29-34
    • Kumar, A.1    Hansen, P.2
  • 6
    • 0034223864 scopus 로고    scopus 로고
    • "A busbar protection technique and its performance during CT saturation and CT ratio-mismatch"
    • Jul
    • M. S. Sachdev, T. S. Sidhu, and H. S. Gill, "A busbar protection technique and its performance during CT saturation and CT ratio-mismatch," IEEE Trans. Power Delivery, vol. 15, no. 3, pp. 895-901, Jul. 2000.
    • (2000) IEEE Trans. Power Delivery , vol.15 , Issue.3 , pp. 895-901
    • Sachdev, M.S.1    Sidhu, T.S.2    Gill, H.S.3
  • 8
    • 0347968154 scopus 로고    scopus 로고
    • "A CT saturation detection algorithm"
    • Jan
    • Y. C. Kang, S. H. Ok, and S. H. Kang, "A CT saturation detection algorithm" IEEE Trans. Power Delivery, vol. 19, no. 1, pp. 78-85, Jan. 2004.
    • (2004) IEEE Trans. Power Delivery , vol.19 , Issue.1 , pp. 78-85
    • Kang, Y.C.1    Ok, S.H.2    Kang, S.H.3
  • 9
    • 0028196198 scopus 로고
    • "Experimental evaluation of EMTP-based current transformer models for protective relay transient study"
    • Jan
    • M. Kezunovic, L. Kojovic, A. Abur, C. W. Fromen, and F. Phillips, "Experimental evaluation of EMTP-based current transformer models for protective relay transient study," IEEE Trans. Power Delivery, vol. 9, no. 1, pp. 405-413, Jan. 1994.
    • (1994) IEEE Trans. Power Delivery , vol.9 , Issue.1 , pp. 405-413
    • Kezunovic, M.1    Kojovic, L.2    Abur, A.3    Fromen, C.W.4    Phillips, F.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.