메뉴 건너뛰기




Volumn 72, Issue 1, 2005, Pages 22-27

Harms technique of C1-C2 fixation with polyaxial screws and rods;Harmsova fixace C1-C2 fixátorem s polyaxiálními šrouby

Author keywords

Atlantoaxial fixation; Atlatoxial instability; Internal fixator; Polyaxial screws

Indexed keywords

ADULT; AGED; ARTICLE; ATLANTOAXIAL DISLOCATION; ATLANTOAXIAL JOINT; BLEEDING; BONE SCREW; CERVICAL SPINE FRACTURE; CERVICAL SPINE INJURY; CLINICAL ARTICLE; COST; FEMALE; HARMS TECHNIQUE; HUMAN; MAGERL TECHNIQUE; MALE; OPERATION DURATION; ORTHOPEDIC EQUIPMENT; OSTEOSYNTHESIS; POSTOPERATIVE COMPLICATION; SPINE STABILIZATION; SURGICAL ANATOMY; SURGICAL TECHNIQUE; X RAY;

EID: 17744373104     PISSN: 00015415     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (31)

References (27)
  • 1
    • 0017871668 scopus 로고
    • Atlanto-axial Arthrodesis by the Wedge Compression Method
    • BROOKS, A. L., JENKINS, E. W.: Atlanto-axial Arthrodesis by the Wedge Compression Method. J. Bone Jt Surg., 60-A: 279-284, 1978.
    • (1978) J. Bone Jt. Surg. , vol.60 A , pp. 279-284
    • Brooks, A.L.1    Jenkins, E.W.2
  • 2
    • 0031927701 scopus 로고    scopus 로고
    • Posterior C1-C2 Screw Fixation for Atlantoaxial Arthrodesis
    • DICKMAN, C. A., SONNTAG, V. K.: Posterior C1-C2 Screw Fixation for Atlantoaxial Arthrodesis. Neurosurgery, 43: 275-280, 1998.
    • (1998) Neurosurgery , vol.43 , pp. 275-280
    • Dickman, C.A.1    Sonntag, V.K.2
  • 3
    • 0031832091 scopus 로고    scopus 로고
    • Posterior Atlantoaxial Facet Screw Fixation in Rheumatoid Arthritis
    • ELERAKY, M. A., MASFERRER, R., SONNTAG, V. K.: Posterior Atlantoaxial Facet Screw Fixation in Rheumatoid Arthritis. J. Neurosurg., 89: 8-12, 1998.
    • (1998) J. Neurosurg. , vol.89 , pp. 8-12
    • Eleraky, M.A.1    Masferrer, R.2    Sonntag, V.K.3
  • 4
    • 0032985799 scopus 로고    scopus 로고
    • Modified Gallie Technique Versus Transarticular Screw Fixation in C1-C2 Fusion
    • FAREY, I. D., NADKARNI, S., SMITH, N.: Modified Gallie Technique Versus Transarticular Screw Fixation in C1-C2 Fusion. Clin. Orthop., 359: 126-135, 1999.
    • (1999) Clin. Orthop. , vol.359 , pp. 126-135
    • Farey, I.D.1    Nadkarni, S.2    Smith, N.3
  • 5
    • 0011948449 scopus 로고
    • Fractures and Dislocations of the Cervical Spine
    • GALLIE, W. E.: Fractures and Dislocations of the Cervical Spine. Amer. J. Surg., 46: 495-499, 1939.
    • (1939) Amer. J. Surg. , vol.46 , pp. 495-499
    • Gallie, W.E.1
  • 6
    • 0032532701 scopus 로고    scopus 로고
    • Safety and Accuracy of Transarticular Screw Fixation C1-C2 Using an Aiming Device. An Anatomic Study
    • GEBHARD, J. S., SCHIMMER, R. C., JEANNERET, B.: Safety and Accuracy of Transarticular Screw Fixation C1-C2 Using an Aiming Device. An Anatomic Study. Spine, 23: 2185-2189, 1998.
    • (1998) Spine , vol.23 , pp. 2185-2189
    • Gebhard, J.S.1    Schimmer, R.C.2    Jeanneret, B.3
  • 7
    • 0028284239 scopus 로고
    • Plate and Screw Fixation for Atlanto-axial Subluxation
    • GOEL, A., LAHERI, V.: Plate and Screw Fixation for Atlanto-axial Subluxation. Acta Neurochir., 129: 47-53, 1994.
    • (1994) Acta Neurochir. , vol.129 , pp. 47-53
    • Goel, A.1    Laheri, V.2
  • 8
    • 0036954405 scopus 로고    scopus 로고
    • Atlantoaxial Fixation Plate and Screw Metod: A Report of 160 Treated Patients
    • GOEL, A., DESAI, K. I., MUZUMDAR, D. P.: Atlantoaxial Fixation Plate and Screw Metod: a Report of 160 Treated Patients. Neurosurgery, 51: 1351-1356, 2002.
    • (2002) Neurosurgery , vol.51 , pp. 1351-1356
    • Goel, A.1    Desai, K.I.2    Muzumdar, D.P.3
  • 9
    • 0025952072 scopus 로고
    • Atlanto-axial Fusion with Transarticular Screw Fixation
    • GROB, D., JEANNERET, B., AEBI, M., MARKWALDER, T. M.: Atlanto-axial Fusion with Transarticular Screw Fixation. J. Bone Jt Surg., 73-B: 972-976, 1991.
    • (1991) J. Bone Jt. Surg. , vol.73 B , pp. 972-976
    • Grob, D.1    Jeanneret, B.2    Aebi, M.3    Markwalder, T.M.4
  • 10
    • 0026694623 scopus 로고
    • Biomechanical Evaluation of Four Different Posterior Atlanto-axial Fixation Techniques
    • GROB, D., CRISCO, J., PANJABI, M., DVORAK, J.: Biomechanical Evaluation of Four Different Posterior Atlanto-axial Fixation Techniques. Spine, 17: 480-490, 1992.
    • (1992) Spine , vol.17 , pp. 480-490
    • Grob, D.1    Crisco, J.2    Panjabi, M.3    Dvorak, J.4
  • 11
    • 0035890208 scopus 로고    scopus 로고
    • Posterior C1-C2 Fusion With Polyaxial Screw and Rod Fixation
    • HARMS, J., MELCHER, P. R.: Posterior C1-C2 Fusion With Polyaxial Screw and Rod Fixation. Spine, 26: 2467-2471, 2001.
    • (2001) Spine , vol.26 , pp. 2467-2471
    • Harms, J.1    Melcher, P.R.2
  • 12
    • 0026618885 scopus 로고
    • Primary Posterior Fusion C 1/2 in Odontoid Fractures: Indications, Technique, and Results of Transarticular Screw Fixation
    • JEANNERET, B., MAGERL, F.: Primary Posterior Fusion C 1/2 in Odontoid Fractures: Indications, Technique, and Results of Transarticular Screw Fixation. J. Spinal Disord., 4: 464-475, 1992.
    • (1992) J. Spinal Disord. , vol.4 , pp. 464-475
    • Jeanneret, B.1    Magerl, F.2
  • 13
    • 0028127420 scopus 로고
    • Posterior Transarticular Screw Fixation of C1-C2
    • JEANNERET, B.: Posterior Transarticular Screw Fixation of C1-C2. Tech. Orthop., 1: 49-59, 1994.
    • (1994) Tech. Orthop. , vol.1 , pp. 49-59
    • Jeanneret, B.1
  • 14
    • 0032100810 scopus 로고    scopus 로고
    • Anatomic Considerations of Anterior Transarticular Screw Fixation for Atlantoaxial Instability
    • LU, J., EBRAHEIM, N.A., YANG, H., HECK, B. E., YEASTING, R. A.: Anatomic Considerations of Anterior Transarticular Screw Fixation for Atlantoaxial Instability. Spine, 23: 1229-1235, 1998.
    • (1998) Spine , vol.23 , pp. 1229-1235
    • Lu, J.1    Ebraheim, N.A.2    Yang, H.3    Heck, B.E.4    Yeasting, R.A.5
  • 15
    • 0002257576 scopus 로고
    • Stable Posterior Fusion of the Atlas and Axis by Transarticular Screw Fixation
    • Kehr, P., Weidner, A. (eds): Wien, Springer
    • MAGERL, F., SEEMANN, P. S.: Stable Posterior Fusion of the Atlas and Axis by Transarticular Screw Fixation. In: Kehr, P., Weidner, A. (eds): Cervical spine. Wien, Springer 1987, 322-327.
    • (1987) Cervical Spine , pp. 322-327
    • Magerl, F.1    Seemann, P.S.2
  • 16
    • 0030973318 scopus 로고    scopus 로고
    • Radiological and Anatomical Evaluation of the Atlantoaxial Transarticular Screw Fixation Technique
    • MADAWI, A. A., CASEY, A. T., SOLANKI, G. A., VERES, R., CROCKARD, H. A.: Radiological and Anatomical Evaluation of the Atlantoaxial Transarticular Screw Fixation Technique. J. Neurosurg., 86: 961-968, 1997.
    • (1997) J. Neurosurg. , vol.86 , pp. 961-968
    • Madawi, A.A.1    Casey, A.T.2    Solanki, G.A.3    Veres, R.4    Crockard, H.A.5
  • 18
    • 0033193322 scopus 로고    scopus 로고
    • Biomechanical Study of Atlantoaxial Arthrodesis: Transarticular Screw Fixation Versus Modified Brooks Posterior Wiring
    • MITCHELL, T. C., SADASIVAN, K. K., OGDEN, A. L., MAYEUX, R. H., MUKHERJEE, D. P., ALBRIGHT, J. A.: Biomechanical Study of Atlantoaxial Arthrodesis: Transarticular Screw Fixation Versus Modified Brooks Posterior Wiring. J. Orthop. Trauma, 13: 483-489, 1999.
    • (1999) J. Orthop. Trauma , vol.13 , pp. 483-489
    • Mitchell, T.C.1    Sadasivan, K.K.2    Ogden, A.L.3    Mayeux, R.H.4    Mukherjee, D.P.5    Albright, J.A.6
  • 19
    • 0032530291 scopus 로고    scopus 로고
    • Biomechanical Comparison of C1-C2 Posterior Fixation. Cable, Graft and Screw Combinations
    • NADERI, S., CRAWFORD, N. R., SONG, G. S., SONNTAG, V. K., DICKMAN, C. A.: Biomechanical Comparison of C1-C2 Posterior Fixation. Cable, Graft and Screw Combinations. Spine, 23: 1946-1955, 1998.
    • (1998) Spine , vol.23 , pp. 1946-1955
    • Naderi, S.1    Crawford, N.R.2    Song, G.S.3    Sonntag, V.K.4    Dickman, C.A.5
  • 20
    • 0036481526 scopus 로고    scopus 로고
    • C1-C2 Pedicle Screw Fixation with Rigid Cantilever Beam Contruct: Case Report and Technical Note
    • RESNICK, D. K., BENZEL, E. C.: C1-C2 Pedicle Screw Fixation with Rigid Cantilever Beam Contruct: Case Report and Technical Note. Neurosurgery, 50: 426-428, 2002.
    • (2002) Neurosurgery , vol.50 , pp. 426-428
    • Resnick, D.K.1    Benzel, E.C.2
  • 26
    • 0032804668 scopus 로고    scopus 로고
    • Anterior C1-C2 Screw Fixation and Bony Fusion Through an Anterior Retropharyngeal Approach
    • VACCARO, A. R., LEHMAN, A. P., AHLGREN, B. D., GARFIN, S. R.: Anterior C1-C2 Screw Fixation and Bony Fusion Through an Anterior Retropharyngeal Approach. Orthopedics, 22: 1165-1170, 1999.
    • (1999) Orthopedics , vol.22 , pp. 1165-1170
    • Vaccaro, A.R.1    Lehman, A.P.2    Ahlgren, B.D.3    Garfin, S.R.4
  • 27
    • 0031896021 scopus 로고    scopus 로고
    • Vertebral Artery Injury in C1-2 Transarticular Screw Fixation: Results of a Survey of the AANS/CNS Section on Disorders of Spine and Peripheral Nerves
    • WRIGHT, N. M., LAURYSSEN, C.: Vertebral Artery Injury in C1-2 Transarticular Screw Fixation: Results of a Survey of the AANS/CNS Section on Disorders of Spine and Peripheral Nerves. J. Neurosurg., 88: 634-640, 1998.
    • (1998) J. Neurosurg. , vol.88 , pp. 634-640
    • Wright, N.M.1    Lauryssen, C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.