메뉴 건너뛰기




Volumn 22, Issue 1, 2005, Pages 3-8

Abdominal ultrasound-guided embryo transfer improves clinical pregnancy rates after in vitro fertilization: Experiences from 330 clinical investigations

Author keywords

Implantation rate; In vitro fertilization; Pregnancy rate; Ultrasound guided embryo transfer

Indexed keywords

ADULT; ARTICLE; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; ECHOGRAPHY; EMBRYO; EMBRYO TRANSFER; FEMALE; FEMALE INFERTILITY; FERTILIZATION IN VITRO; HUMAN; HUMAN CELL; INFERTILITY THERAPY; INTRACYTOPLASMIC SPERM INJECTION; MAJOR CLINICAL STUDY; NIDATION; PREGNANCY RATE; PRIORITY JOURNAL; PROSPECTIVE STUDY; RANDOMIZATION; RANDOMIZED CONTROLLED TRIAL;

EID: 17644424288     PISSN: 10580468     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10815-005-0813-0     Document Type: Article
Times cited : (20)

References (22)
  • 1
    • 0029559997 scopus 로고
    • Clinical approaches to increasing uterine receptivity during human implantation
    • Ewards RG: Clinical approaches to increasing uterine receptivity during human implantation. Hum Reprod 1995;10(Suppl. 2):60-66
    • (1995) Hum Reprod , vol.10 , Issue.2 SUPPL. , pp. 60-66
    • Ewards, R.G.1
  • 2
    • 0027285450 scopus 로고
    • Transfer of embryos into the uterus: How much do technical factors affect pregnancy rates?
    • Al-Shawaf T, Dave R, Harper J, et al.: Transfer of embryos into the uterus: How much do technical factors affect pregnancy rates? J Assist Reprod Genet 1993;10(1):31-36
    • (1993) J Assist Reprod Genet , vol.10 , Issue.1 , pp. 31-36
    • Al-Shawaf, T.1    Dave, R.2    Harper, J.3
  • 4
    • 0034008630 scopus 로고    scopus 로고
    • Embryo transfer under ultrasound guidance improves pregnancy rates in in-vitro fertilization
    • Coroleu B, Carreras O, Veiga A. et al.: Embryo transfer under ultrasound guidance improves pregnancy rates in in-vitro fertilization. Hum Reprod 2000;15(3):616-620
    • (2000) Hum Reprod , vol.15 , Issue.3 , pp. 616-620
    • Coroleu, B.1    Carreras, O.2    Veiga, A.3
  • 5
    • 0036181466 scopus 로고    scopus 로고
    • The influence of the depth of embryo replacement into the uterine cavity on implantation rates after IVF: A controlled, ultrasound-guided study
    • Coroleu B, Barri PN, Carreras O, et al.: The influence of the depth of embryo replacement into the uterine cavity on implantation rates after IVF: A controlled, ultrasound-guided study. Hum Reprod 2002;17(2):341-346
    • (2002) Hum Reprod , vol.17 , Issue.2 , pp. 341-346
    • Coroleu, B.1    Barri, P.N.2    Carreras, O.3
  • 6
    • 0036852870 scopus 로고    scopus 로고
    • The usefulness of ultrasound guidance in frozen-thawed embryo transfer: A prospective randomized clinical trial
    • Coroleu B, Barri PN, Carreras O, et al.: The usefulness of ultrasound guidance in frozen-thawed embryo transfer: A prospective randomized clinical trial. Hum Reprod 2002; 17(11):2885-2890
    • (2002) Hum Reprod , vol.17 , Issue.11 , pp. 2885-2890
    • Coroleu, B.1    Barri, P.N.2    Carreras, O.3
  • 7
    • 0036068051 scopus 로고    scopus 로고
    • Ultrasound-guided embryo transfer improved pregnancy rates and increases the frequency of easy transfer
    • Matorras R, Urquijo E, Mendoza, et al.: Ultrasound-guided embryo transfer improved pregnancy rates and increases the frequency of easy transfer. Hum Reprod 2002;17(7):1762-1766
    • (2002) Hum Reprod , vol.17 , Issue.7 , pp. 1762-1766
    • Matorras, R.1    Urquijo, E.2    Mendoza3
  • 8
    • 0033982594 scopus 로고    scopus 로고
    • Ultrasound-guided soft catheter embryo transfers will improve pregnancy rates in in-vitro fertilization
    • Wood EG, Batzer FR, Go KJ, et al.: Ultrasound-guided soft catheter embryo transfers will improve pregnancy rates in in-vitro fertilization. Hum Reprod 2000;15(1):107-112
    • (2000) Hum Reprod , vol.15 , Issue.1 , pp. 107-112
    • Wood, E.G.1    Batzer, F.R.2    Go, K.J.3
  • 9
    • 0035156365 scopus 로고    scopus 로고
    • Ultrasound guided embryo transfer: A prospective randomized controlled trial
    • Tang OS, Ng EH, So WW, et al.: Ultrasound guided embryo transfer: A prospective randomized controlled trial. Hum Reprod 2001;16(11):2310-2315
    • (2001) Hum Reprod , vol.16 , Issue.11 , pp. 2310-2315
    • Tang, O.S.1    Ng, E.H.2    So, W.W.3
  • 10
    • 0242460512 scopus 로고    scopus 로고
    • Effectiveness of human menopausal gonadotropin versus recombinant follicle-stimulating hormone for controlled ovarian hyperstimulation in assisted reproductive cycles: A meta-analysis
    • Van Wely M, Westergaard LG, Bossuyt PM, et al.: Effectiveness of human menopausal gonadotropin versus recombinant follicle-stimulating hormone for controlled ovarian hyperstimulation in assisted reproductive cycles: A meta-analysis. Fertil Steril 2003;80(5):1086-1093
    • (2003) Fertil Steril , vol.80 , Issue.5 , pp. 1086-1093
    • Van Wely, M.1    Westergaard, L.G.2    Bossuyt, P.M.3
  • 11
    • 0037381367 scopus 로고    scopus 로고
    • Prospective evaluation of two stimulation protocols for low responders who were undergoing in vitro fertilization-embryo transfer
    • Weissman A, Farhi J, Royburt M, et al.: Prospective evaluation of two stimulation protocols for low responders who were undergoing in vitro fertilization-embryo transfer. Fertil Steril 2003;79(4):886-892
    • (2003) Fertil Steril , vol.79 , Issue.4 , pp. 886-892
    • Weissman, A.1    Farhi, J.2    Royburt, M.3
  • 12
    • 0037905792 scopus 로고    scopus 로고
    • Recent advances in the production of viable human embryos in vitro
    • Pool TB: Recent advances in the production of viable human embryos in vitro. Reprod Biomed Online 2002;4(3):294-302
    • (2002) Reprod Biomed Online , vol.4 , Issue.3 , pp. 294-302
    • Pool, T.B.1
  • 13
    • 0036901734 scopus 로고    scopus 로고
    • Improvement in early human embryo development using new formulation sequential stage-specific culture media
    • Cooke S, Quinn P, Kime L, et al.: Improvement in early human embryo development using new formulation sequential stage-specific culture media. Fertil Steril 2002;78(6):1254-1260
    • (2002) Fertil Steril , vol.78 , Issue.6 , pp. 1254-1260
    • Cooke, S.1    Quinn, P.2    Kime, L.3
  • 14
    • 0036326202 scopus 로고    scopus 로고
    • Assessment of uterine receptivity by the endometrial-subendometrial blood flow distribution pattern in women undergoing in vitro fertilization-embryo transfer
    • Chien LW, Au HK, Chen PL, et al.: Assessment of uterine receptivity by the endometrial-subendometrial blood flow distribution pattern in women undergoing in vitro fertilization-embryo transfer. Fertil Steril 2002;78(2):245-251
    • (2002) Fertil Steril , vol.78 , Issue.2 , pp. 245-251
    • Chien, L.W.1    Au, H.K.2    Chen, P.L.3
  • 15
    • 0036107425 scopus 로고    scopus 로고
    • Optimizing the embryo transfer
    • Mansour RT, Aboulhar MA: Optimizing the embryo transfer. Hum Reprod 2002;17(5):1149-1153
    • (2002) Hum Reprod , vol.17 , Issue.5 , pp. 1149-1153
    • Mansour, R.T.1    Aboulhar, M.A.2
  • 16
    • 0141923617 scopus 로고    scopus 로고
    • Ultrasound-guided embryo transfer: A meta-analysis of randomized controlled trials
    • Sallam HN, Sadek SS: Ultrasound-guided embryo transfer: A meta-analysis of randomized controlled trials. Fertil Steril 2003;80(4):1042-1046
    • (2003) Fertil Steril , vol.80 , Issue.4 , pp. 1042-1046
    • Sallam, H.N.1    Sadek, S.S.2
  • 17
    • 0141889041 scopus 로고    scopus 로고
    • A meta-analysis of ultrasound-guided versus clinical touch embryo transfer
    • Buckett WM: A meta-analysis of ultrasound-guided versus clinical touch embryo transfer. Fertil Steril 2003;80(4):1037-1041
    • (2003) Fertil Steril , vol.80 , Issue.4 , pp. 1037-1041
    • Buckett, W.M.1
  • 18
    • 0036063124 scopus 로고    scopus 로고
    • Ultrasound measurement of the uterocervical angle before embryo transfer: A prospective controlled study
    • Sallam HN, Agameya AF, Rahman AF, et al.: Ultrasound measurement of the uterocervical angle before embryo transfer: A prospective controlled study. Hum Reprod 2002;17(7):1767-1772
    • (2002) Hum Reprod , vol.17 , Issue.7 , pp. 1767-1772
    • Sallam, H.N.1    Agameya, A.F.2    Rahman, A.F.3
  • 19
    • 0031665402 scopus 로고    scopus 로고
    • Ultrasound tracking of the movement of embryo-associated air bubbles on standing after transfer
    • Woolcott R, Stanger J: Ultrasound tracking of the movement of embryo-associated air bubbles on standing after transfer. Hum Reprod 1998;13(8):2107-2109
    • (1998) Hum Reprod , vol.13 , Issue.8 , pp. 2107-2109
    • Woolcott, R.1    Stanger, J.2
  • 20
    • 0035654107 scopus 로고    scopus 로고
    • Transvaginal ultrasound-guided embryo transfer improves pregnancy and implantation rates after IVF
    • Kojima K, Nomiyama M, Kumamoto T, et al.: Transvaginal ultrasound-guided embryo transfer improves pregnancy and implantation rates after IVF. Hum Reprod 2001;16(12):2578-2582
    • (2001) Hum Reprod , vol.16 , Issue.12 , pp. 2578-2582
    • Kojima, K.1    Nomiyama, M.2    Kumamoto, T.3
  • 21
  • 22
    • 0032880225 scopus 로고    scopus 로고
    • Junctional zone contractions and embryo transfer: Is it safe to use a tenaculum?
    • Lesny P, Killick SR, Robinson J, et al.: Junctional zone contractions and embryo transfer: Is it safe to use a tenaculum? Hum Reprod 1999;14(9):2367-2370
    • (1999) Hum Reprod , vol.14 , Issue.9 , pp. 2367-2370
    • Lesny, P.1    Killick, S.R.2    Robinson, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.