메뉴 건너뛰기




Volumn 221, Issue 1-4, 2004, Pages 210-214

Biological effectiveness of antiproton annihilation

(22)  Holzscheiter, Michael H a   Agazaryan, Nzhde b   Bassler, Niels c   Beyer, Gerd d   DeMarco, John J b   Doser, Michael e   Ichioka, Toshiyasu c   Iwamoto, Keisuke S b   Knudsen, Helge V c   Landua, Rolf e   Maggiore, Carl a   McBride, William H b   Møller, Søren Pape c   Petersen, Jorgen f   Smathers, James B b   Skarsgard, Lloyd D g   Solberg, Timothy D b   Uggerhøj, Ulrik I c   Withers, H Rodney b   Vranjes, Sanja h   more..


Author keywords

Antiproton annihilation; Biological response; Bragg peak

Indexed keywords

BACKSCATTERING; BIOLOGICAL RADIATION EFFECTS; DOSIMETRY; IONIZATION; IRRADIATION; MONTE CARLO METHODS; RADIOTHERAPY;

EID: 17544391779     PISSN: 0168583X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.nimb.2004.03.057     Document Type: Conference Paper
Times cited : (21)

References (9)
  • 1
    • 0021356385 scopus 로고
    • Possible biomedical applications of antiproton beams: Focused radiation transfer
    • Gray L., Kalogeropoulos T.E. Possible biomedical applications of antiproton beams: focused radiation transfer. Radiat. Res. 97:1984;246.
    • (1984) Radiat. Res. , vol.97 , pp. 246
    • Gray, L.1    Kalogeropoulos, T.E.2
  • 2
    • 0022352947 scopus 로고
    • A measurement of the local energy deposition by antiprotons coming to rest in tissue-like material
    • Sullivan A.H. A measurement of the local energy deposition by antiprotons coming to rest in tissue-like material. Phys. Med. Biol. 30(12):1985;1297.
    • (1985) Phys. Med. Biol. , vol.30 , Issue.12 , pp. 1297
    • Sullivan, A.H.1
  • 6
    • 17344393006 scopus 로고    scopus 로고
    • Biological effectiveness of antiproton annihilation
    • Maggiore C., et al. Biological effectiveness of antiproton annihilation. Nucl. Instr. and Meth. B. 214:2004;181.
    • (2004) Nucl. Instr. and Meth. B , vol.214 , pp. 181
    • Maggiore, C.1
  • 7
    • 0029785770 scopus 로고    scopus 로고
    • Measurements of relative biological effectivness of the 70 MeV proton beam at TRIUMF using Chinese hamster V79 cells and the high-precision cell sorter assay
    • Wouters B.G., et al. Measurements of relative biological effectivness of the 70 MeV proton beam at TRIUMF using Chinese hamster V79 cells and the high-precision cell sorter assay. Radiat. Res. 146:1996;159.
    • (1996) Radiat. Res. , vol.146 , pp. 159
    • Wouters, B.G.1
  • 8
    • 0020364701 scopus 로고
    • Radiobiology of pions at TRIUMF
    • Skarsgard L.D., et al. Radiobiology of pions at TRIUMF. Int. J. Radiat. Biol. Phys. 8(12):1982;2127.
    • (1982) Int. J. Radiat. Biol. Phys. , vol.8 , Issue.12 , pp. 2127
    • Skarsgard, L.D.1
  • 9
    • 24444470712 scopus 로고    scopus 로고
    • Antiproton intensity measurement in the ATHENA beam line at CERN AD
    • 12 December
    • Makoto C. Fujiwara; Antiproton intensity measurement in the ATHENA beam line at CERN AD, Athena technical report AT/00-01, 12 December 2000.
    • (2000) Athena Technical Report , vol.AT-00-01
    • Fujiwara, M.C.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.