메뉴 건너뛰기




Volumn 66, Issue 4, 2005, Pages 656-660

Assessment of the effect of dilution of blood samples with sodium heparin on blood gas, electrolyte, and lactate measurements in dogs

Author keywords

[No Author keywords available]

Indexed keywords

ANTICOAGULANT AGENT; BICARBONATE; CALCIUM ION; CARBON DIOXIDE; CHLORIDE; ELECTROLYTE; HEPARIN; LACTIC ACID; OXYGEN; POTASSIUM; SODIUM;

EID: 17544367772     PISSN: 00029645     EISSN: None     Source Type: Journal    
DOI: 10.2460/ajvr.2005.66.656     Document Type: Article
Times cited : (63)

References (15)
  • 1
    • 0028280444 scopus 로고
    • Interference in ionized calcium measurements by heparin salts
    • Landt M, Hortin GL, Smith CH, et al. Interference in ionized calcium measurements by heparin salts. Clin Chem 1994; 40:565-570.
    • (1994) Clin. Chem. , vol.40 , pp. 565-570
    • Landt, M.1    Hortin, G.L.2    Smith, C.H.3
  • 2
    • 0019966579 scopus 로고
    • Oxygen affinity and Bohr coefficients of dog blood
    • Reeves RB, Park JA, Lapenna GN, et al. Oxygen affinity and Bohr coefficients of dog blood. J Appl Physiol 1982;53:87-95.
    • (1982) J. Appl. Physiol. , vol.53 , pp. 87-95
    • Reeves, R.B.1    Park, J.A.2    Lapenna, G.N.3
  • 4
    • 0017935582 scopus 로고
    • Heparin sodium and arterial blood gas analysis
    • Scheinhorn DJ, Angelillo VA. Heparin sodium and arterial blood gas analysis. Chest 1978;73:244-245.
    • (1978) Chest , vol.73 , pp. 244-245
    • Scheinhorn, D.J.1    Angelillo, V.A.2
  • 5
    • 0344800287 scopus 로고
    • Sampling and storing of blood for determination of acid-base status
    • Siggaard-Anderson O. Sampling and storing of blood for determination of acid-base status. Scand J Clin Lab Invest 1961;13:196-204.
    • (1961) Scand. J. Clin. Lab. Invest. , vol.13 , pp. 196-204
    • Siggaard-Anderson, O.1
  • 6
    • 0021433223 scopus 로고
    • The effect of heparin dilution on arterial blood gas analysis
    • Dake MD, Peters J, Teague R. The effect of heparin dilution on arterial blood gas analysis. West J Med 1984;140:792-793.
    • (1984) West J. Med. , vol.140 , pp. 792-793
    • Dake, M.D.1    Peters, J.2    Teague, R.3
  • 7
    • 0002485615 scopus 로고    scopus 로고
    • Introduction to acid-base disorders
    • DiBartola SP, ed. 2nd ed. Philadelphia: WB Saunders Co
    • DiBartola SP. Introduction to acid-base disorders. In: DiBartola SP, ed. Fluid therapy in small animal practice. 2nd ed. Philadelphia: WB Saunders Co, 2000;189-210.
    • (2000) Fluid Therapy in Small Animal Practice , pp. 189-210
    • DiBartola, S.P.1
  • 8
    • 0018092914 scopus 로고
    • Arterial blood gas analysis: Potential errors due to the addition of heparin
    • Hamilton RD, Crockett RJ, Alpers JH. Arterial blood gas analysis: potential errors due to the addition of heparin. Anaesth Intensive Care 1978;6:251-255.
    • (1978) Anaesth. Intensive Care , vol.6 , pp. 251-255
    • Hamilton, R.D.1    Crockett, R.J.2    Alpers, J.H.3
  • 9
    • 0037745979 scopus 로고    scopus 로고
    • Composition and distribution of body fluids in dogs and cats
    • DiBartola SP, ed. 2nd ed. Philadelphia: WB Saunders Co
    • Kohn CW. Composition and distribution of body fluids in dogs and cats. In: DiBartola SP, ed. Fluid therapy in small animal practice 2nd ed. Philadelphia: WB Saunders Co, 2000;3-25.
    • (2000) Fluid Therapy in Small Animal Practice , pp. 3-25
    • Kohn, C.W.1
  • 10
    • 0032757802 scopus 로고    scopus 로고
    • Self-prepared heparinized syringes for measuring ionized magnesium in critical care patients
    • Chantler J, Cox DJ. Self-prepared heparinized syringes for measuring ionized magnesium in critical care patients. Br J Anaesth 1999;83:810-812.
    • (1999) Br. J. Anaesth. , vol.83 , pp. 810-812
    • Chantler, J.1    Cox, D.J.2
  • 11
    • 0028809297 scopus 로고
    • Zinc heparin introduces a preanalytical error in the measurement of ionized calcium concentration
    • Lyon ME, Guajardo M, Laha T, et al. Zinc heparin introduces a preanalytical error in the measurement of ionized calcium concentration. Scand J Clin Lab Invest 1995;55:61-65.
    • (1995) Scand. J. Clin. Lab. Invest. , vol.55 , pp. 61-65
    • Lyon, M.E.1    Guajardo, M.2    Laha, T.3
  • 12
    • 0028351186 scopus 로고
    • Bias of ionized calcium results from blood gas syringes
    • Swanson JR, Heeter C, Limbocker M, et al. Bias of ionized calcium results from blood gas syringes. Clin Chem 1994; 40:669-670.
    • (1994) Clin. Chem. , vol.40 , pp. 669-670
    • Swanson, J.R.1    Heeter, C.2    Limbocker, M.3
  • 13
    • 0025892676 scopus 로고
    • In vitro evaluation of a heparinized blood sampler for ionized calcium measurement
    • Sachs CH, Rabouine RH, Chaneac M, et al. In vitro evaluation of a heparinized blood sampler for ionized calcium measurement. Ann Clin Biochem 1991;28:240-244.
    • (1991) Ann. Clin. Biochem. , vol.28 , pp. 240-244
    • Sachs, C.H.1    Rabouine, R.H.2    Chaneac, M.3
  • 14
    • 0028347826 scopus 로고
    • Use of novel preparations of heparin to eliminate interference in ionized calcium measurements: Have all the problems been solved?
    • Toffaletti J. Use of novel preparations of heparin to eliminate interference in ionized calcium measurements: have all the problems been solved? Clin Chem 1994;40:508-509.
    • (1994) Clin. Chem. , vol.40 , pp. 508-509
    • Toffaletti, J.1
  • 15
    • 0020960742 scopus 로고
    • Too much heparin: Possible source of error in blood gas analysis
    • Hutchison AS, Ralston SH, Dryburgh FJ, et al. Too much heparin: possible source of error in blood gas analysis. Br Med J 1983; 287:1131-1132.
    • (1983) Br. Med. J. , vol.287 , pp. 1131-1132
    • Hutchison, A.S.1    Ralston, S.H.2    Dryburgh, F.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.