Volumn 47, Issue 3, 2005, Pages 729-733

Optimization of the hets he-cooled divertor concept: Thermal fluid and structural analysis

Author keywords

[No Author keywords available]

Indexed keywords

FLUID DYNAMICS; FUSION REACTIONS; HEAT FLUX; HEAT SHIELDING; NUCLEAR POWER PLANTS; OPTIMIZATION; PRESSURE EFFECTS; STRUCTURAL ANALYSIS; TEMPERATURE CONTROL; THERMOANALYSIS;

EID: 17444408193     PISSN: 15361055     EISSN: None     Source Type: Journal    
DOI: 10.13182/FST05-A772     Document Type: Conference Paper
Times cited : (2)

References (7)
  • 1
    • 3342915124 scopus 로고    scopus 로고
    • Gas-cooled high performance divertor for a power plant
    • San Diego, USA
    • S. Hermsmeyer, S. Malang, 'Gas-cooled high performance divertor for a power plant', Proc. ISFNT-6, San Diego, USA (2002).
    • (2002) Proc. ISFNT-6
    • Hermsmeyer, S.1    Malang, S.2
  • 5
    • 17444390746 scopus 로고
    • Preliminary critical heat flux assessment of the high efficiency thermal shield device
    • A. Pizzuto, B. Riccardi, "Preliminary critical heat flux assessment of the High Efficiency Thermal Shield device", Transactions of XVI IEEE/MPTS SOFE (1995).
    • (1995) Transactions of XVI IEEE/MPTS SOFE
    • Pizzuto, A.1    Riccardi, B.2
  • 6
    • 0038454579 scopus 로고    scopus 로고
    • Thermal fluid finite element calculations for the European PPCS divertor concepts
    • P.J. Karditsas and N.P. Taylor, "Thermal fluid finite element calculations for the European PPCS divertor concepts", Fusion science and Technology 44, No.1 (2003).
    • (2003) Fusion Science and Technology , vol.44 , Issue.1
    • Karditsas, P.J.1    Taylor, N.P.2