메뉴 건너뛰기




Volumn 16, Issue 1, 2005, Pages 98-104

The bone-metal interface of defect and press-fit ingrowth of microwave plasma-chemical vapor deposition implants in the rabbit model

Author keywords

Bone metal interface; Defect healing; Diamond coating; Implant; MWP CVD

Indexed keywords

BIOMATERIAL; DIAMOND; INORGANIC COMPOUND; METAL; SILICON CARBIDE; SILICON DERIVATIVE; TITANIUM; TITANIUM ALLOY (TIAL6V4);

EID: 17444398078     PISSN: 09057161     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1600-0501.2004.01079.x     Document Type: Article
Times cited : (12)

References (19)
  • 2
    • 0027629233 scopus 로고
    • Haemocompatibility optimisation of implants by hybrid structuring
    • Bolz, A. & Schaldach, M. (1993) Haemocompatibility optimisation of implants by hybrid structuring. Medical & Biological Engineering & Computing 31 (Suppl.): 123-130.
    • (1993) Medical & Biological Engineering & Computing , vol.31 , Issue.SUPPL. , pp. 123-130
    • Bolz, A.1    Schaldach, M.2
  • 3
    • 0032824351 scopus 로고    scopus 로고
    • Biomechanical and morphometric analysisi of hydroxy apatite-coated implants with varying crystallinity
    • Chang, Y.-L., Lew, D., Park, J.B. & Keller, J.C. (1999) Biomechanical and morphometric analysisi of hydroxy apatite-coated implants with varying crystallinity. Journal of Oral and Maxillofacial Surgery 57: 1096-1108.
    • (1999) Journal of Oral and Maxillofacial Surgery , vol.57 , pp. 1096-1108
    • Chang, Y.-L.1    Lew, D.2    Park, J.B.3    Keller, J.C.4
  • 4
    • 0029239540 scopus 로고
    • In vivo mechanical and histological characteristics of HA-coated implants vary with coating vendor
    • Dalton, J.E. & Cook, S.D. (1995) In vivo mechanical and histological characteristics of HA-coated implants vary with coating vendor. Journal of Biomedical Material Research 29: 239-245.
    • (1995) Journal of Biomedical Material Research , vol.29 , pp. 239-245
    • Dalton, J.E.1    Cook, S.D.2
  • 6
    • 0023083116 scopus 로고
    • Klinische und histopathologische Befunde im Implantatlagergewebe bei Titan-Implantaten
    • Donath, K. (1987) Klinische und histopathologische Befunde im Implantatlagergewebe bei Titan-Implantaten. Zahnärztliche Welt Zahnärztliche Rundschau 96: 14-16.
    • (1987) Zahnärztliche Welt Zahnärztliche Rundschau , vol.96 , pp. 14-16
    • Donath, K.1
  • 7
    • 0006854950 scopus 로고
    • Licht- Und elektronenmikroskopische Untersuchung zur Biostabilität dentaler Titanimplantate
    • Hillmann, G. & Donath, K. (1991) Licht- und elektronenmikroskopische Untersuchung zur Biostabilität dentaler Titanimplantate. Zeitschrift für Zahnärztliche Implantologie VII: 170-177.
    • (1991) Zeitschrift für Zahnärztliche Implantologie , vol.7 , pp. 170-177
    • Hillmann, G.1    Donath, K.2
  • 9
    • 0023805329 scopus 로고
    • Biomaterial and implant surfaces: On the role of cleanliness, contamination, and preparation procedures
    • Kasemo, B. &. Lausmaa, J. (1988) Biomaterial and implant surfaces: on the role of cleanliness, contamination, and preparation procedures. Journal of Biomedical Material Research 22: 145-158.
    • (1988) Journal of Biomedical Material Research , vol.22 , pp. 145-158
    • Kasemo, B.1    Lausmaa, J.2
  • 10
    • 0031262838 scopus 로고    scopus 로고
    • Animal experiments for testing a hydroxyapatite ceramic coating under vacuum conditions
    • Kettner, R., Jänicke, S. & Schmitz, H.-J. (1997) Animal experiments for testing a hydroxyapatite ceramic coating under vacuum conditions. Mund-Kiefer-Gesichtschirurgie 6: 335-339.
    • (1997) Mund-Kiefer-Gesichtschirurgie , vol.6 , pp. 335-339
    • Kettner, R.1    Jänicke, S.2    Schmitz, H.-J.3
  • 11
    • 0010844724 scopus 로고    scopus 로고
    • The interface between bone and implants with different surface oxide properties
    • Larsson, C. (2000) The interface between bone and implants with different surface oxide properties. Applied Osseointegration Research 1: 9-14.
    • (2000) Applied Osseointegration Research , vol.1 , pp. 9-14
    • Larsson, C.1
  • 12
    • 0034489967 scopus 로고    scopus 로고
    • Hydroxyapatite and their use as coatings in dental implants: A review
    • Ong, J.L. & Chan, D.C.N. (1999) Hydroxyapatite and their use as coatings in dental implants: a review. Biomedical Engineering 28: 667-707.
    • (1999) Biomedical Engineering , vol.28 , pp. 667-707
    • Ong, J.L.1    Chan, D.C.N.2
  • 17