메뉴 건너뛰기




Volumn 2, Issue , 2004, Pages 902-907

Effectiveness of unified power quality conditioner for Flicker mitigation

Author keywords

Control strategies and parameters; Demanded powers of active filters; Electrical arc furnace; Flicker; Linearised model; Parallel and series active filter; Power flow components; Subharmonics; Subharmonics compensation; Unified power quality conditioner

Indexed keywords

ACTIVE FILTERS; COMPUTER SIMULATION; ELECTRIC CURRENTS; ELECTRIC POTENTIAL; FLICKERING; LINEARIZATION; NATURAL FREQUENCIES; NETWORKS (CIRCUITS); PERTURBATION TECHNIQUES;

EID: 17444365798     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (4)

References (6)
  • 1
    • 17444405373 scopus 로고    scopus 로고
    • Application to a STATCOM
    • Graz, Austria, September, CD-ROM
    • G. De Préville, Flicker Mitigation, "Application to a STATCOM," EPE 2001, Graz, Austria, September 2001, CD-ROM.
    • (2001) EPE 2001
    • De Préville, G.1    Mitigation, F.2
  • 2
    • 0032025040 scopus 로고    scopus 로고
    • The unified power quality conditioner. The integration of series-and shunt-active filters
    • March
    • H. Fugita, H. Akagi, "The Unified Power Quality conditioner. The Integration of Series-and Shunt-Active Filters," IEEE Trans. On PE-13, No.2, March 1998, 315-322.
    • (1998) IEEE Trans. on PE-13 , vol.2 , pp. 315-322
    • Fugita, H.1    Akagi, H.2
  • 3
    • 0003619993 scopus 로고    scopus 로고
    • Evaluation of power-ratings for active power quality compensators
    • Lausanne, Switzerland, CD-ROM
    • D. D. Bester, A. D. Le Roux, H. T. Monston, J. H. R. Enslin, "Evaluation of Power-Ratings for Active Power Quality Compensators," EPE 1999, Lausanne, Switzerland, 1999, CD-ROM.
    • (1999) EPE 1999
    • Bester, D.D.1    Le Roux, A.D.2    Monston, H.T.3    Enslin, J.H.R.4
  • 4
    • 6344253674 scopus 로고    scopus 로고
    • A PWM-operated voltage source converter for Flicker mitigation
    • Trondheim, Norway
    • T. Larsson, A. Ekstrom, "A PWM-Operated Voltage Source Converter for Flicker Mitigation," EPE 1997, Trondheim, Norway, 1997, 3.1.16-3.1.20.
    • (1997) EPE 1997
    • Larsson, T.1    Ekstrom, A.2
  • 5
    • 6344237951 scopus 로고    scopus 로고
    • UPFC application to suppress Flicker nn arc furnace supply system
    • Trondheim, Norway
    • M. Zouti, S. Saadate, "UPFC Application to Suppress Flicker nn Arc Furnace Supply System," EPE 1997, Trondheim, Norway, 1997, 3.983-3.987.
    • (1997) EPE 1997
    • Zouti, M.1    Saadate, S.2
  • 6
    • 0030289837 scopus 로고    scopus 로고
    • New trends in active filters for power conditioning
    • H. Akagi, "New Trends in Active Filters for Power Conditioning," IEEE Transactions on IA-32, No. 6, 1996, 1312-1322.
    • (1996) IEEE Transactions on IA-32 , vol.6 , pp. 1312-1322
    • Akagi, H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.