메뉴 건너뛰기




Volumn 32, Issue 2, 2005, Pages 145-149

Interaction of blood-cells/-components and tissue cells with body foreign surfaces in a cone plate rheometer under hydrodynamic shear load

Author keywords

Biomaterial surfaces; Clotting thrombus formation; GP VI antibody; Hemocompatibility; Histocompatibility; Platelets; Rheometer; Rheometer system; Shear stress

Indexed keywords

BIOMATERIAL;

EID: 17244362625     PISSN: 13860291     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Conference Paper
Times cited : (3)

References (7)
  • 1
    • 0037709839 scopus 로고    scopus 로고
    • The importance of angiogenesis in the interaction between polymeric biomaterials and surrounding tissue
    • D. Rickert, A. Lendlein, S. Kelch and R.P. Franke, The importance of angiogenesis in the interaction between polymeric biomaterials and surrounding tissue, Clin. Hemorheol. Microcirc. 28 (2003), 175-182.
    • (2003) Clin. Hemorheol. Microcirc. , vol.28 , pp. 175-182
    • Rickert, D.1    Lendlein, A.2    Kelch, S.3    Franke, R.P.4
  • 5
    • 0041662218 scopus 로고    scopus 로고
    • Influence of the direkt NO-donor SIN-1 on the interaction between platelets and stainless steel stents under dynamic conditions
    • F. Jung, C. Mrowietz, U.T. Seyfert, R. Grewe and R.P. Franke, Influence of the direkt NO-donor SIN-1 on the interaction between platelets and stainless steel stents under dynamic conditions, Clin. Hemorheol. Microcirc. 28 (2003), 189-199.
    • (2003) Clin. Hemorheol. Microcirc. , vol.28 , pp. 189-199
    • Jung, F.1    Mrowietz, C.2    Seyfert, U.T.3    Grewe, R.4    Franke, R.P.5
  • 6
    • 0034991781 scopus 로고    scopus 로고
    • Light and scanning-electron microscopic examination of coronary stents in a perfusion-model. Effects of an NO-donor/quantitative analysis
    • R.P. Franke, P. Reuter, C. Mrowietz, R. Bach and F. Jung, Light and scanning-electron microscopic examination of coronary stents in a perfusion-model. Effects of an NO-donor/quantitative analysis, Clin. Hemorheol. Microcirc. 24 (2001), 101-109.
    • (2001) Clin. Hemorheol. Microcirc. , vol.24 , pp. 101-109
    • Franke, R.P.1    Reuter, P.2    Mrowietz, C.3    Bach, R.4    Jung, F.5
  • 7
    • 0030799803 scopus 로고    scopus 로고
    • Biochemische Analytik der Hämokompatibilität
    • U.T. Seyfert, S. Mörsdorf, J. Riggert and F. Jung, Biochemische Analytik der Hämokompatibilität, Clin. Lab. 43 (1997), 571-582.
    • (1997) Clin. Lab. , vol.43 , pp. 571-582
    • Seyfert, U.T.1    Mörsdorf, S.2    Riggert, J.3    Jung, F.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.