메뉴 건너뛰기




Volumn 109 PART 2, Issue , 2003, Pages 339-349

Comparison of air exchange efficiency and contaminant removal effectiveness as IAQ indices

Author keywords

[No Author keywords available]

Indexed keywords

AIR POLLUTION CONTROL; AIR POLLUTION CONTROL EQUIPMENT; AIR QUALITY; EFFICIENCY; INDOOR AIR POLLUTION;

EID: 17144453216     PISSN: 00012505     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (68)

References (17)
  • 1
    • 0009402017 scopus 로고    scopus 로고
    • ASHRAE; Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • ASHRAE. 1997. ANSI/ASHRAE Standard 129-1997, Measuring Air-Change Effectiveness. Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • (1997) ANSI/ASHRAE Standard 129-1997, Measuring Air-Change Effectiveness
  • 2
    • 0242703033 scopus 로고    scopus 로고
    • ASHRAE; Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • ASHRAE. 2001. ASHRAE Standard 62-2001, Ventilation for acceptable indoor air quality. Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • (2001) ASHRAE Standard 62-2001, Ventilation for Acceptable Indoor Air Quality
  • 3
    • 0003842369 scopus 로고    scopus 로고
    • Performance evaluation and development of design guidelines for displacement ventilation
    • ASHRAE Research Project - RP-949, Report to ASHRAE TC 5.3 - Room Air Distribution
    • Chen, Q., L.R. Glicksman, X. Yuan, S. Hu, and Y. Hu. 1998. Performance Evaluation and Development of Design Guidelines for Displacement Ventilation. ASHRAE Research Project - RP-949, Report to ASHRAE TC 5.3 - Room Air Distribution.
    • (1998)
    • Chen, Q.1    Glicksman, L.R.2    Yuan, X.3    Hu, S.4    Hu, Y.5
  • 6
    • 0001763660 scopus 로고
    • New ventilation efficiency scales based on spatial distribution of contaminant concentrations aided by numerical simulation
    • Kato, S., and S. Murakami, 1988. New ventilation efficiency scales based on spatial distribution of contaminant concentrations aided by numerical simulation. ASHRAE Transactions 94(2): 309-330.
    • (1988) ASHRAE Transactions , vol.94 , Issue.2 , pp. 309-330
    • Kato, S.1    Murakami, S.2
  • 9
    • 0004098383 scopus 로고    scopus 로고
    • The box method - A practical procedure for introduction of an air terminal devices in CFD calculation
    • Institute for Bygningsteknik, Aalborg University, Denmark
    • Nielsen, P.V. 1997. The box method - a practical procedure for introduction of an air terminal devices in CFD calculation. Institute for Bygningsteknik, Aalborg University, Denmark.
    • (1997)
    • Nielsen, P.V.1
  • 11
    • 0002000961 scopus 로고
    • Air change effectiveness measurement in two modern office buildings
    • Persily, A.K., W.S. Dols, and S.J. Nabinger. 1994. Air Change Effectiveness Measurement in Two Modern Office Buildings. Indoor Air journal 4: 40-55.
    • (1994) Indoor Air Journal , vol.4 , pp. 40-55
    • Persily, A.K.1    Dols, W.S.2    Nabinger, S.J.3
  • 12
    • 0019682545 scopus 로고
    • What is ventilation efficiency?
    • Sandberg, M. 1981. What is ventilation efficiency? Building and Environment 16(2): 123-135.
    • (1981) Building and Environment , vol.16 , Issue.2 , pp. 123-135
    • Sandberg, M.1
  • 16
    • 0035570664 scopus 로고    scopus 로고
    • A method of test to obtain diffuser data for CFD modeling of room airflow
    • Srebric, J., and Q. Chen. 2001. A method of test to obtain diffuser data for CFD modeling of room airflow. ASHRAE Transactions 107(2).
    • (2001) ASHRAE Transactions , vol.107 , Issue.2
    • Srebric, J.1    Chen, Q.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.