메뉴 건너뛰기




Volumn 1, Issue , 2004, Pages 157-160

Hierarchical segmentation of multiple sclerosis lesions in multi-sequence MRI

Author keywords

[No Author keywords available]

Indexed keywords

BRAIN; COMPUTATIONAL METHODS; HIERARCHICAL SYSTEMS; IMAGE SEGMENTATION; PROBABILITY; TISSUE;

EID: 17144426115     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (31)

References (14)
  • 1
    • 17144388495 scopus 로고    scopus 로고
    • IRM et sclérose en plaques
    • A. Tourbah, "IRM et sclérose en plaques," Neurologies, vol. 4, no. 33, pp. 270-274, 2001.
    • (2001) Neurologies , vol.4 , Issue.33 , pp. 270-274
    • Tourbah, A.1
  • 2
    • 0036230317 scopus 로고    scopus 로고
    • Mise au point: Les techniques d'analyse quantitative des IRM cérébrales: Application à la sclérose en plaque
    • J. Grimaud, Y.-M. Zhu, and M. Rombaut, "Mise au point: Les techniques d'analyse quantitative des IRM cérébrales: application à la sclérose en plaque," Revue Neurologique, vol. 158, no. 3, pp. 381-389, 2002.
    • (2002) Revue Neurologique , vol.158 , Issue.3 , pp. 381-389
    • Grimaud, J.1    Zhu, Y.-M.2    Rombaut, M.3
  • 4
    • 0037161249 scopus 로고    scopus 로고
    • MRI techniques to monitor MS evolution: The present and the future
    • M. Filippi and R.I. Grossman, "MRI techniques to monitor MS evolution: the present and the future," Neurology, vol. 58, no. 8, pp. 1147-1153, 2002.
    • (2002) Neurology , vol.58 , Issue.8 , pp. 1147-1153
    • Filippi, M.1    Grossman, R.I.2
  • 5
    • 0036720996 scopus 로고    scopus 로고
    • Serial isotropic three-dimensional fast FLAIR imaging: Using image registration and subtraction to reveal active multiple sclerosis lesions
    • I.L. Tan, R.A. van Schijndel, P.J. Pouwels, H.J. Ader, and F. Barkhof, "Serial isotropic three-dimensional fast FLAIR imaging: using image registration and subtraction to reveal active multiple sclerosis lesions," AJR Am J Roentgenol, vol. 179, no. 3, pp. 777-82, 2002.
    • (2002) AJR Am J Roentgenol , vol.179 , Issue.3 , pp. 777-782
    • Tan, I.L.1    Van Schijndel, R.A.2    Pouwels, P.J.3    Ader, H.J.4    Barkhof, F.5
  • 6
    • 0035053108 scopus 로고    scopus 로고
    • Accuracy for detection of simulated lesions: Comparison of fluid-attenuated inversion-recovery, proton density-weighted, and T2-weighted synthetic brain MR imaging
    • E.H. Herskovits, R. Itoh, and E.R. Melhem, "Accuracy for detection of simulated lesions: comparison of fluid-attenuated inversion-recovery, proton density-weighted, and T2-weighted synthetic brain MR imaging," AJR Am J Roentgenol, vol. 176, no. 5, pp. 1313-8, 2001.
    • (2001) AJR Am J Roentgenol , vol.176 , Issue.5 , pp. 1313-1318
    • Herskovits, E.H.1    Itoh, R.2    Melhem, E.R.3
  • 7
    • 0035413307 scopus 로고    scopus 로고
    • Automated segmentation of multiple sclerosis lesions by model outlier detection
    • K. Van Leemput, F. Macs, D. Vandermeulen, A. Colchester, and P. Suetens, "Automated segmentation of multiple sclerosis lesions by model outlier detection," IEEE TMI, vol. 20, no. 8, pp. 677-688, 2001.
    • (2001) IEEE TMI , vol.20 , Issue.8 , pp. 677-688
    • Van Leemput, K.1    Macs, F.2    Vandermeulen, D.3    Colchester, A.4    Suetens, P.5
  • 8
    • 0029377853 scopus 로고
    • Model-based 3D segmentation of multiple sclerosis lesions in magnetic resonance images
    • M. Kamber, R. Shinghal, D.L. Collins, G.S. Francis, and A.C. Evans, "Model-based 3D segmentation of multiple sclerosis lesions in magnetic resonance images," IEEE TMI, vol. 14, no. 3, pp. 442-453, 1995.
    • (1995) IEEE TMI , vol.14 , Issue.3 , pp. 442-453
    • Kamber, M.1    Shinghal, R.2    Collins, D.L.3    Francis, G.S.4    Evans, A.C.5
  • 9
    • 0030126711 scopus 로고    scopus 로고
    • Segmentation of multiple sclerosis lesions in intensity corrected multispectral MRI
    • B. Johnston, M.S. Atkins, B. Mackiewich, and M. Anderson, "Segmentation of multiple sclerosis lesions in intensity corrected multispectral MRI," IEEE TMI, vol. 15, no. 2, pp. 154-169, 1996.
    • (1996) IEEE TMI , vol.15 , Issue.2 , pp. 154-169
    • Johnston, B.1    Atkins, M.S.2    Mackiewich, B.3    Anderson, M.4
  • 10
    • 0035152169 scopus 로고    scopus 로고
    • Reconstructing a 3D structure from serial histological sections
    • Jan.
    • S. Ourselin, A. Roche, G. Subsol, X. Pennee, and N. Ayache, "Reconstructing a 3D structure from serial histological sections," Image and Vision Computing, vol. 19, no. 1-2, pp. 25-31, Jan. 2001.
    • (2001) Image and Vision Computing , vol.19 , Issue.1-2 , pp. 25-31
    • Ourselin, S.1    Roche, A.2    Subsol, G.3    Pennee, X.4    Ayache, N.5
  • 12
    • 0027608265 scopus 로고
    • Automatic detection of brain contours in MRI data sets
    • M.E. Brummer, R.M. Mersereau, R.L. Eisner, and R.R.J. Lewine, "Automatic detection of brain contours in MRI data sets," IEEE TMI, vol. 12, no. 2, pp. 153-166, 1993.
    • (1993) IEEE TMI , vol.12 , Issue.2 , pp. 153-166
    • Brummer, M.E.1    Mersereau, R.M.2    Eisner, R.L.3    Lewine, R.R.J.4
  • 13
    • 0002629270 scopus 로고
    • Maximum likelihood from incomplete data via the EM algorithm
    • A. Dempster, N. Laird, and D. Rubin, "Maximum likelihood from incomplete data via the EM algorithm," Journal of the Royal Statistical Society, vol. 39, no. 1, pp. 1-38, 1977.
    • (1977) Journal of the Royal Statistical Society , vol.39 , Issue.1 , pp. 1-38
    • Dempster, A.1    Laird, N.2    Rubin, D.3
  • 14
    • 0036891369 scopus 로고    scopus 로고
    • Estimation of the partial volume effect in MRI
    • M.A. González Ballester, A. Zisserman, and M. Brady, "Estimation of the partial volume effect in MRI," Medical Image Analysis, vol. 6, no. 4, pp. 389-405, 2002.
    • (2002) Medical Image Analysis , vol.6 , Issue.4 , pp. 389-405
    • Ballester, M.A.G.1    Zisserman, A.2    Brady, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.