Volumn 42, Issue 2, 2005, Pages 105-111

Prednisolone measurement in human serum using liquid chromatography tandem spectrometry

Author keywords

[No Author keywords available]

Indexed keywords

PREDNISOLONE;

EID: 17144404604     PISSN: 00045632     EISSN: None     Source Type: Journal    
DOI: 10.1258/0004563053492810     Document Type: Article
Times cited : (12)

References (14)
  • 1
    • 0015216741 scopus 로고
    • The Boston Collaborative Drug Surveillance Program: Prednisolone side effects and serum protein levels
    • Lewis GP, Jusko WJ, Burke CW, Groves L. The Boston Collaborative Drug Surveillance Program: prednisolone side effects and serum protein levels. Lancet 1971; 2: 778-9
    • (1971) Lancet , vol.2 , pp. 778-779
    • Lewis, G.P.1    Jusko, W.J.2    Burke, C.W.3    Groves, L.4
  • 3
    • 0017613114 scopus 로고
    • Effectiveness of prednisolone during phenytoin therapy
    • Petereit LB, Mietkle AW. Effectiveness of prednisolone during phenytoin therapy. Clin Pharmacol Ther 1977; 22: 912-6
    • (1977) Clin Pharmacol Ther , vol.22 , pp. 912-916
    • Petereit, L.B.1    Mietkle, A.W.2
  • 4
    • 0015969460 scopus 로고
    • Decreased clearance of prednisolone, a factor in the development of corticosteroid side effects
    • Kozower M, Veatch L, Kaplan MM. Decreased clearance of prednisolone, a factor in the development of corticosteroid side effects. J Clin Endocrinol Metab 1974; 38: 407-12
    • (1974) J Clin Endocrinol Metab , vol.38 , pp. 407-412
    • Kozower, M.1    Veatch, L.2    Kaplan, M.M.3
  • 5
  • 6
    • 3342920597 scopus 로고    scopus 로고
    • Area-under-the-curve monitoring of prednisolone for dose optimization in a stable renal transplant population
    • Potter JM, McWhinney BC, Sampson L, Hickman PE. Area-under-the-curve monitoring of prednisolone for dose optimization in a stable renal transplant population. Ther Drug Monitor 2004; 26: 408-14
    • (2004) Ther Drug Monitor , vol.26 , pp. 408-414
    • Potter, J.M.1    McWhinney, B.C.2    Sampson, L.3    Hickman, P.E.4
  • 7
    • 0032549543 scopus 로고    scopus 로고
    • Simultaneous determination of glucocorticoids in plasma or urine by high-performance liquid chromatography with pre-column derivatization by 9-anthroyl nitrile
    • Shibata N, Hayakawa T, Takada K, Hoshino N, Minouchi T, Yamaji A. Simultaneous determination of glucocorticoids in plasma or urine by high-performance liquid chromatography with pre-column derivatization by 9-anthroyl nitrile. J Chromatogr B 1998; 706: 191-9
    • (1998) J Chromatogr B , vol.706 , pp. 191-199
    • Shibata, N.1    Hayakawa, T.2    Takada, K.3    Hoshino, N.4    Minouchi, T.5    Yamaji, A.6
  • 8
    • 0027930643 scopus 로고
    • Fifteen years of operation of a high-performance liquid chromatographic assay for prednisolone, cortisol and prednisolone in plasma
    • Jusko WJ, Pyszczynski NA, Bushway MS, D'Ambrosio R, Mis SM. Fifteen years of operation of a high-performance liquid chromatographic assay for prednisolone, cortisol and prednisolone in plasma. J Chromatogr B 1994; 658: 47-64
    • (1994) J Chromatogr B , vol.658 , pp. 47-64
    • Jusko, W.J.1    Pyszczynski, N.A.2    Bushway, M.S.3    D'Ambrosio, R.4    Mis, S.M.5
  • 9
    • 0035082789 scopus 로고    scopus 로고
    • Simultaneous determination of plasma prednisolone, prednisone and cortisol levels by high-performance liquid chromatography
    • Majid O, Akhlaghi F, Lee T, Holt DW, Trull A. Simultaneous determination of plasma prednisolone, prednisone and cortisol levels by high-performance liquid chromatography. Ther Drug Monitor 2001; 23: 163-8
    • (2001) Ther Drug Monitor , vol.23 , pp. 163-168
    • Majid, O.1    Akhlaghi, F.2    Lee, T.3    Holt, D.W.4    Trull, A.5
  • 10
    • 0030954818 scopus 로고    scopus 로고
    • Quantitative determination of several synthetic corticosteroids by gas chromatography-mass spectrometry after purification by immunoaffinity chromatography
    • Delahaut PH, Jacquemin P, Colemonts Y, Dubois M, De Graeve J, Deluyker H. Quantitative determination of several synthetic corticosteroids by gas chromatography-mass spectrometry after purification by immunoaffinity chromatography. J Chromatogr B 1997; 698: 203-15
    • (1997) J Chromatogr B , vol.698 , pp. 203-215
    • Delahaut, P.H.1    Jacquemin, P.2    Colemonts, Y.3    Dubois, M.4    De Graeve, J.5    Deluyker, H.6
  • 11
    • 0042600533 scopus 로고    scopus 로고
    • Determination of prednisolone in serum: Method development using solid-phase extraction and micellar electrokinetic chromatography
    • Noé S, Böhler J, Keller E, Fram AW. Determination of prednisolone in serum: method development using solid-phase extraction and micellar electrokinetic chromatography. J Pharm Biomed Anal 1998; 18: 471-6
    • (1998) J Pharm Biomed Anal , vol.18 , pp. 471-476
    • Noé, S.1    Böhler, J.2    Keller, E.3    Fram, A.W.4
  • 12
    • 1342306732 scopus 로고    scopus 로고
    • Determination of glucocorticoids prednisone, prednisolone, dexamethasone and cortisol in human serum using liquid chromatography coupled to tandem mass spectrometry
    • Frerichs VA, Tornatore KM. Determination of glucocorticoids prednisone, prednisolone, dexamethasone and cortisol in human serum using liquid chromatography coupled to tandem mass spectrometry. J Chromatogr B 2004; 802: 329-38
    • (2004) J Chromatogr B , vol.802 , pp. 329-338
    • Frerichs, V.A.1    Tornatore, K.M.2
  • 13
    • 0005905707 scopus 로고    scopus 로고
    • US Department of Health and Human Services, Food and Drug Administration, Center for Drug Evaluation and Research (CDER) and Center for Vetinary Medicine (CVM), May
    • Guidance for Industry. Bioanalytical Method Validation. US Department of Health and Human Services, Food and Drug Administration, Center for Drug Evaluation and Research (CDER) and Center for Vetinary Medicine (CVM), May 2001
    • (2001) Bioanalytical Method Validation
  • 14
    • 0038574979 scopus 로고    scopus 로고
    • Ion suppression in mass spectrometry
    • Annesley TM. Ion suppression in mass spectrometry. Clin Chem 2003; 49: 1041-4.
    • (2003) Clin Chem , vol.49 , pp. 1041-1044
    • Annesley, T.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.