메뉴 건너뛰기




Volumn 150, Issue 5, 2003, Pages 635-640

Modular power system topology assessment using Gaussian potential functions

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTATIONAL COMPLEXITY; COMPUTER ARCHITECTURE; ELECTRIC POWER SYSTEMS; ENERGY MANAGEMENT; KNOWLEDGE BASED SYSTEMS; NEURAL NETWORKS; SCADA SYSTEMS;

EID: 17044454292     PISSN: 13502360     EISSN: None     Source Type: Journal    
DOI: 10.1049/ip-gtd:20030738     Document Type: Article
Times cited : (11)

References (7)
  • 1
    • 0026107595 scopus 로고
    • Detection and identification of topological errors in online power system analysis
    • Singh, N., and Glavitsch, H.: 'Detection and identification of topological errors in online power system analysis', IEEE Trans. Power Syst., 1991, 6, (1), 324-331
    • (1991) IEEE Trans. Power Syst. , vol.6 , Issue.1 , pp. 324-331
    • Singh, N.1    Glavitsch, H.2
  • 2
    • 0024103954 scopus 로고
    • Detection and identification of topology errors in electric power systems
    • Clements, K.A., and Davis, P.W.: 'Detection and identification of topology errors in electric power systems', IEEE Trans. Power Syst., 1988, 3, (4), pp. 1748-1753
    • (1988) IEEE Trans. Power Syst. , vol.3 , Issue.4 , pp. 1748-1753
    • Clements, K.A.1    Davis, P.W.2
  • 3
    • 0027695763 scopus 로고
    • Identification of topology errors in power systems state estimation
    • Simoes Costa, A., and Leao, J.A.: 'Identification of topology errors in power systems state estimation', IEEE Trans. Power Syst., 1993, 8, (4), pp. 1531-1538
    • (1993) IEEE Trans. Power Syst. , vol.8 , Issue.4 , pp. 1531-1538
    • Simoes Costa, A.1    Leao, J.A.2
  • 5
    • 0032137680 scopus 로고    scopus 로고
    • On-line topology determination and bad data suppression in power system operation using artificial neural networks
    • Souza, J.C.S., Alvas Da Silva, A.P., and Leite Da Silva, A.M.: 'On-line topology determination and bad data suppression in power system operation using artificial neural networks', IEEE Trans. Power Syst., 1998, 13, (3), pp. 796-803
    • (1998) IEEE Trans. Power Syst. , vol.13 , Issue.3 , pp. 796-803
    • Souza, J.C.S.1    Alvas Da Silva, A.P.2    Leite Da Silva, A.M.3
  • 6
    • 0033221819 scopus 로고    scopus 로고
    • A robust estimation method for topology error identification
    • Mili, L., Steeno, G., Dobraca, F., and French, D.: 'A robust estimation method for topology error identification', IEEE Trans. Power Syst., 1999, 14, (4), pp. 1469-1476
    • (1999) IEEE Trans. Power Syst. , vol.14 , Issue.4 , pp. 1469-1476
    • Mili, L.1    Steeno, G.2    Dobraca, F.3    French, D.4
  • 7
    • 0025839504 scopus 로고
    • A gaussian potential function network with hierarchically self-organizing learning
    • Lee, S., and Kil, R.M.: 'A Gaussian potential function network with hierarchically self-organizing learning', Neural Netw., 1991, 4, pp. 207-224
    • (1991) Neural Netw. , vol.4 , pp. 207-224
    • Lee, S.1    Kil, R.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.