메뉴 건너뛰기




Volumn 49, Issue 4, 2003, Pages 218-229

The Accuracy Quantification of Thermal-Hydraulic Code Predictions;Ocenjevanje natančnosti napovedi termohicdravličnih programov

Author keywords

BETHSY; Code accuracy; SARBM; Thermal hydraulic code

Indexed keywords

APPROXIMATION THEORY; CODES (STANDARDS); NUCLEAR REACTORS;

EID: 17044450093     PISSN: 00392480     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (1)

References (20)
  • 1
    • 0002444379 scopus 로고
    • Evaluation of accuracy of thermal-hydraulic code calculations
    • Ambrosini, W., R. Bovalini, F. D'Auria (1990) Evaluation of accuracy of thermal-hydraulic code calculations. Energia Nucleare 1, 5-16.
    • (1990) Energia Nucleare , vol.1 , pp. 5-16
    • Ambrosini, W.1    Bovalini, R.2    D'Auria, F.3
  • 3
    • 0031245970 scopus 로고    scopus 로고
    • Determination of code accuracy in predicting small-break LOCA experiment
    • La Grange Park
    • Mavko, B., A. Prošek, F. D'Auria (1997) Determination of code accuracy in predicting small-break LOCA experiment. Nuclear Technology 120, La Grange Park, 1-19.
    • (1997) Nuclear Technology , vol.120 , pp. 1-19
    • Mavko, B.1    Prošek, A.2    D'Auria, F.3
  • 4
    • 0036706457 scopus 로고    scopus 로고
    • Review of quantitative accuracy assessments with fast Fourier transform based method (FFTBM)
    • Prošek, A., F. D'Auria, B. Mavko (2002). Review of quantitative accuracy assessments with fast Fourier transform based method (FFTBM). Nuclear Engineering and Design 217, 179-206.
    • (2002) Nuclear Engineering and Design , vol.217 , pp. 179-206
    • Prošek, A.1    D'Auria, F.2    Mavko, B.3
  • 9
    • 0141630970 scopus 로고    scopus 로고
    • BETHSY Test 6.9c: Loss of residual heat removal system during mid-loop operation
    • Dorchester, United Kingdom: AEA Technology
    • Mavko, B., S. Petelin, M. Jurkovič (1997) BETHSY Test 6.9c: Loss of residual heat removal system during mid-loop operation. Comparison Report (Draft Version 1.2), Dorchester, United Kingdom: AEA Technology.
    • (1997) Comparison Report (Draft Version 1.2)
    • Mavko, B.1    Petelin, S.2    Jurkovič, M.3
  • 14
    • 4243997161 scopus 로고    scopus 로고
    • Quantitative accuracy assessment of thermalhydraulic code predictions with SARBM
    • ortorož,10-.13. September 2001
    • Prošek, A. (2001) Quantitative accuracy assessment of thermalhydraulic code predictions with SARBM. Proceedings of Int. Conf. Nuclear Energy in Central Europe 2001, ortorož,10-.13. September 2001.
    • (2001) Proceedings of Int. Conf. Nuclear Energy in Central Europe 2001
    • Prošek, A.1
  • 16
    • 0141630974 scopus 로고
    • General description
    • Equipe BETHSY Grenoble: Centre d'etudes nucleaires de Grenoble
    • Equipe BETHSY (1990) General description. Note SETh/LES/90-97, Grenoble: Centre d'etudes nucleaires de Grenoble.
    • (1990) Note SETh/LES/90-97
  • 17
    • 0141854497 scopus 로고
    • Break modelling for RELAP5/MOD2 analyses of ISP-Bethsy
    • Chicago
    • Petelin, S., O. Gortnar, B. Mavko, I. Parzer (1992) Break modelling for RELAP5/MOD2 analyses of ISP-Bethsy. ANS Transactions 66, Chicago, 621-622.
    • (1992) ANS Transactions , vol.66 , pp. 621-622
    • Petelin, S.1    Gortnar, O.2    Mavko, B.3    Parzer, I.4
  • 19
    • 0141854498 scopus 로고
    • BETHSY experiment 9.1b2′ cold leg break without HPSI and with delayed ultimate procedure
    • Paris
    • OECD NEA (1992) OECD/NEA/CSNI International Standard Problem No. 27: BETHSY experiment 9.1b2′ cold leg break without HPSI and with delayed ultimate procedure, Paris.
    • (1992) OECD/NEA/CSNI International Standard Problem No. 27 , vol.27


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.