메뉴 건너뛰기




Volumn 9, Issue 6, 2004, Pages 307-309

Determinants of white-coat hypertension

Author keywords

Ambulatory blood pressure measurement; Clinic blood pressure measurement; Clinical characteristics; White coat hypertension

Indexed keywords

ADULT; AGE DISTRIBUTION; AGED; BLOOD PRESSURE MEASUREMENT; BLOOD PRESSURE MONITORING; CLINICAL FEATURE; CONFERENCE PAPER; FEMALE; HUMAN; MAJOR CLINICAL STUDY; MALE; MULTIVARIATE LOGISTIC REGRESSION ANALYSIS; PREDICTION; PREVALENCE; PRIORITY JOURNAL; SEX DIFFERENCE; WHITE COAT HYPERTENSION;

EID: 17044406329     PISSN: 13595237     EISSN: None     Source Type: Journal    
DOI: 10.1097/00126097-200412000-00007     Document Type: Conference Paper
Times cited : (92)

References (16)
  • 1
    • 84920232154 scopus 로고
    • Effects of blood pressure measurement by the doctor on patient's blood pressure and heart rate
    • Mancia G, Grassi G, Pomidossi G, Gregorini L, Bertineri G, Parati G, et al. Effects of blood pressure measurement by the doctor on patient's blood pressure and heart rate. Lancet 1983; 2: 695-698.
    • (1983) Lancet , vol.2 , pp. 695-698
    • Mancia, G.1    Grassi, G.2    Pomidossi, G.3    Gregorini, L.4    Bertineri, G.5    Parati, G.6
  • 2
    • 0028245879 scopus 로고
    • Blood pressure measurement and detection of hypertension
    • Pickering TG. Blood pressure measurement and detection of hypertension. Lancet 1994; 344:31-35.
    • (1994) Lancet , vol.344 , pp. 31-35
    • Pickering, T.G.1
  • 3
    • 0038460302 scopus 로고    scopus 로고
    • The seventh report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure: The JNC 7 Report
    • Chobanian AV, Bakris GL, Black HR, Cushman WC, Green LA, Izzo JL. Jr, et al. The seventh report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure: the JNC 7 Report. JAMA 2003; 289:2560-2571.
    • (2003) JAMA , vol.289 , pp. 2560-2571
    • Chobanian, A.V.1    Bakris, G.L.2    Black, H.R.3    Cushman, W.C.4    Green, L.A.5    Izzo Jr., J.L.6
  • 4
    • 12444277817 scopus 로고    scopus 로고
    • European Society of Hypertension recommendations for conventional, ambulatory and home blood pressure measurement
    • O'Brien E, Asmar R, Beilin L, Imai Y, Mallion J-M, Mancia G, et al., on behalf of the European Society of Hypertension Working Group on Blood Pressure Monitoring. European Society of Hypertension recommendations for conventional, ambulatory and home blood pressure measurement. J Hypertens 2003; 21:821-848.
    • (2003) J Hypertens , vol.21 , pp. 821-848
    • O'Brien, E.1    Asmar, R.2    Beilin, L.3    Imai, Y.4    Mallion, J.-M.5    Mancia, G.6
  • 5
    • 1542432170 scopus 로고    scopus 로고
    • British Hypertension Society: Guidelines for management of hypertension. Report of the fourth working party of the British Hypertension Society, 2004-BHS IV
    • Williams B, Poulter NR, Brown MJ, Davis M, McInnes GT, Potter JF, et al. British Hypertension Society: guidelines for management of hypertension. Report of the fourth working party of the British Hypertension Society, 2004-BHS IV. J Hum Hypertens 2004; 18:139-185.
    • (2004) J Hum Hypertens , vol.18 , pp. 139-185
    • Williams, B.1    Poulter, N.R.2    Brown, M.J.3    Davis, M.4    McInnes, G.T.5    Potter, J.F.6
  • 6
    • 0032480780 scopus 로고    scopus 로고
    • Cardiovascular outcome in white-coat versus sustained mild hypertension: A 10-year follow-up study
    • Khattar RS, Senior R, Lahiri A. Cardiovascular outcome in white-coat versus sustained mild hypertension: a 10-year follow-up study. Circulation 1998; 98:1892-1897.
    • (1998) Circulation , vol.98 , pp. 1892-1897
    • Khattar, R.S.1    Senior, R.2    Lahiri, A.3
  • 7
    • 0036931267 scopus 로고    scopus 로고
    • Ambulatory Blood Pressure and Treatment of Hypertension Trial Investigators, Cardiovascular risk in white-coat and sustained hypertensive patients
    • Celis H, Staessen JA, Thijs L, Buntinx F, De Buyzere M, Den Hond E, et al. Ambulatory Blood Pressure and Treatment of Hypertension Trial Investigators, Cardiovascular risk in white-coat and sustained hypertensive patients. Blood Press Monit 2002; 11:352-356.
    • (2002) Blood Press Monit , vol.11 , pp. 352-356
    • Celis, H.1    Staessen, J.A.2    Thijs, L.3    Buntinx, F.4    De Buyzere, M.5    Den Hond, E.6
  • 8
    • 0001743041 scopus 로고
    • Validation of the SpaceLabs 90202 ambulatory blood pressure recorder
    • O'Brien E, Sheridan J, Browne T, Conroy R, O'Malley K. Validation of the SpaceLabs 90202 ambulatory blood pressure recorder. J Hypertens 1989; 7(Suppl 6):S388-S389.
    • (1989) J Hypertens , vol.7 , Issue.SUPPL. 6
    • O'Brien, E.1    Sheridan, J.2    Browne, T.3    Conroy, R.4    O'Malley, K.5
  • 9
    • 0025873917 scopus 로고
    • Accuracy of the SpaceLabs 90207 determined by the British Hypertension Protocol
    • O'Brien E, Mee F, Atkins N, O'Malley K. Accuracy of the SpaceLabs 90207 determined by the British Hypertension Protocol. J Hypertens 1991; 9: 573-574.
    • (1991) J Hypertens , vol.9 , pp. 573-574
    • O'Brien, E.1    Mee, F.2    Atkins, N.3    O'Malley, K.4
  • 10
    • 0002700425 scopus 로고
    • A customized international database system for storing and analysing ambulatory blood pressure measurements and related data
    • Abstract
    • Atkins N, Mee F, O'Brien E. A customized international database system for storing and analysing ambulatory blood pressure measurements and related data. Abstract. J Hypertens 1994; 12:323.
    • (1994) J Hypertens , vol.12 , pp. 323
    • Atkins, N.1    Mee, F.2    O'Brien, E.3
  • 11
    • 0032821875 scopus 로고    scopus 로고
    • Diagnosis of white-coat hypertension by ambulatory blood pressure monitoring
    • Owens P, Atkins N, O'Brien E. Diagnosis of white-coat hypertension by ambulatory blood pressure monitoring. Hypertension 1999; 34:267-272.
    • (1999) Hypertension , vol.34 , pp. 267-272
    • Owens, P.1    Atkins, N.2    O'Brien, E.3
  • 12
    • 1842426223 scopus 로고    scopus 로고
    • Evaluation of three devices for self-measurement of blood pressure according to the revised British Hypertension Society Protocol: The Omron HEM-705CP, Phillips HP5332, and Nissei DS-175
    • O'Brien E, Mee F, Atkins N, Thomas M. Evaluation of three devices for self-measurement of blood pressure according to the revised British Hypertension Society Protocol: the Omron HEM-705CP, Phillips HP5332, and Nissei DS-175. Blood Press Monit 1996; 1:55-61.
    • (1996) Blood Press Monit , vol.1 , pp. 55-61
    • O'Brien, E.1    Mee, F.2    Atkins, N.3    Thomas, M.4
  • 13
    • 0037235262 scopus 로고    scopus 로고
    • When can the practicing physician suspect white-coat hypertension? Statement from the Working Group on Blood Pressure Monitoring of the European Society of Hypertension
    • European Society of Hypertension Working Group on Blood Pressure Monitoring
    • Verdecchia P, O'Brien E, Pickering T, Staessen JA, Parati G, Myers M, et al. European Society of Hypertension Working Group on Blood Pressure Monitoring. When can the practicing physician suspect white-coat hypertension? Statement from the Working Group on Blood Pressure Monitoring of the European Society of Hypertension. Am J Hypertens 2003; 16:87-91.
    • (2003) Am J Hypertens , vol.16 , pp. 87-91
    • Verdecchia, P.1    O'Brien, E.2    Pickering, T.3    Staessen, J.A.4    Parati, G.5    Myers, M.6
  • 15
    • 0027422098 scopus 로고
    • Short report: Ambulatory blood pressure in normotensive compared with hypertensive subjects
    • The Ad-Hoc Working Group
    • Staessen JA, O'Brien ET, Atkins N, Amery AK. Short report: ambulatory blood pressure in normotensive compared with hypertensive subjects The Ad-Hoc Working Group. J Hypertens 1993; 11:1289-1297.
    • (1993) J Hypertens , vol.11 , pp. 1289-1297
    • Staessen, J.A.1    O'Brien, E.T.2    Atkins, N.3    Amery, A.K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.