메뉴 건너뛰기




Volumn 13, Issue 3, 2004, Pages 150-159

An experimental study on particular physical properties of several interocclusal recording media. Part II: Linear dimensional change and accompanying weight change

Author keywords

Bite registration materials; Interocclusal recording media; Linear change; Weight change

Indexed keywords

BIOMEDICAL AND DENTAL MATERIALS; RAMITEC; SILICONE DERIVATIVE;

EID: 16644402560     PISSN: 1059941X     EISSN: 1532849X     Source Type: Journal    
DOI: 10.1111/j.1532-849X.2004.04024.x     Document Type: Article
Times cited : (37)

References (26)
  • 4
    • 0019581896 scopus 로고
    • Accuracy and dimensional stability of four interocclusal recording materials
    • Balthazar-Hart Y, Sandrik JL, Malone WF, et al: Accuracy and dimensional stability of four interocclusal recording materials. J Prosthet Dent 1981;45:586-591
    • (1981) J Prosthet Dent , vol.45 , pp. 586-591
    • Balthazar-Hart, Y.1    Sandrik, J.L.2    Malone, W.F.3
  • 5
    • 0028540514 scopus 로고
    • A study of the surface hardness and dimensional stability of several intermaxillary registration materials
    • Chai J, Tan E, Pang IC: A study of the surface hardness and dimensional stability of several intermaxillary registration materials. Int J Prosthodont 1994;7:538-542
    • (1994) Int J Prosthodont , vol.7 , pp. 538-542
    • Chai, J.1    Tan, E.2    Pang, I.C.3
  • 10
    • 0013930715 scopus 로고
    • Characterization of the setting process of silicone dental rubbers
    • Braden M, Elliott JC: Characterization of the setting process of silicone dental rubbers. J Dent Res 1966;45:1016-1023
    • (1966) J Dent Res , vol.45 , pp. 1016-1023
    • Braden, M.1    Elliott, J.C.2
  • 11
    • 29044434893 scopus 로고
    • Investigation of gas bubble defects on die stone poured in vinylpolysiloxane impressions
    • Zhang K, Lacy A: Investigation of gas bubble defects on die stone poured in vinylpolysiloxane impressions (Abstract). J Dent Res 1987;66:132, 208
    • (1987) J Dent Res , vol.66 , pp. 132
    • Zhang, K.1    Lacy, A.2
  • 12
    • 0024066799 scopus 로고
    • Review of dental impression materials
    • Craig RG: Review of dental impression materials. Adv Dent Res 1988;2:51-64
    • (1988) Adv Dent Res , vol.2 , pp. 51-64
    • Craig, R.G.1
  • 13
    • 0028415804 scopus 로고
    • Differential accuracy of elastomeric recording materials and associated weight change
    • Millstein PL, Hsu CC: Differential accuracy of elastomeric recording materials and associated weight change. J Prosthet Dent 1994;71:400-403
    • (1994) J Prosthet Dent , vol.71 , pp. 400-403
    • Millstein, P.L.1    Hsu, C.C.2
  • 14
    • 0024614533 scopus 로고
    • Wettability of a hydrophilic addition silicone impression material
    • Pratten DH, Craig RG: Wettability of a hydrophilic addition silicone impression material. J Prosthet Dent 1989;61:197-202
    • (1989) J Prosthet Dent , vol.61 , pp. 197-202
    • Pratten, D.H.1    Craig, R.G.2
  • 15
    • 0018524103 scopus 로고
    • The effect of nonionic surfactants on bubble entrapment in elastomeric impression materials
    • Norling BK, Reisbick MH: The effect of nonionic surfactants on bubble entrapment in elastomeric impression materials. J Prosthet Dent 1979;42:342-347
    • (1979) J Prosthet Dent , vol.42 , pp. 342-347
    • Norling, B.K.1    Reisbick, M.H.2
  • 18
    • 0018509768 scopus 로고
    • Accuracy and dimensional stability of elastomeric impression materials
    • Eames WB, Wallace SW, Suway NB, et al: Accuracy and dimensional stability of elastomeric impression materials. J Prosthet Dent 1979;42:159-162
    • (1979) J Prosthet Dent , vol.42 , pp. 159-162
    • Eames, W.B.1    Wallace, S.W.2    Suway, N.B.3
  • 19
    • 0019440013 scopus 로고
    • Comparison of elastomeric impression materials used in fixed prosthodontics
    • Ciesco JN, Malone WF, Sandrik JL, et al: Comparison of elastomeric impression materials used in fixed prosthodontics. J Prosthet Dent 1981;45:89-94
    • (1981) J Prosthet Dent , vol.45 , pp. 89-94
    • Ciesco, J.N.1    Malone, W.F.2    Sandrik, J.L.3
  • 20
    • 0031066676 scopus 로고    scopus 로고
    • Comparing the accuracy of reversible hydrocolloid and elastomeric impression materials
    • Federick DR, Caputo A: Comparing the accuracy of reversible hydrocolloid and elastomeric impression materials. J Am Dent Assoc 1997;128:183-188
    • (1997) J Am Dent Assoc , vol.128 , pp. 183-188
    • Federick, D.R.1    Caputo, A.2
  • 21
    • 0013912324 scopus 로고
    • Melting, flow, and thermal expansion characteristics of some dental and commercial waxes
    • Ohashi M, Paffenbarger GC: Melting, flow, and thermal expansion characteristics of some dental and commercial waxes. J Am Dent Assoc 1966;72:1141-1150
    • (1966) J Am Dent Assoc , vol.72 , pp. 1141-1150
    • Ohashi, M.1    Paffenbarger, G.C.2
  • 22
    • 0347969338 scopus 로고
    • Distortion of wax patterns as influenced by storage time, storage temperature and temperature of wax manipulation
    • Phillips RW, Biggs DH: Distortion of wax patterns as influenced by storage time, storage temperature and temperature of wax manipulation. J Am Dent Assoc 1950;41:28-33
    • (1950) J Am Dent Assoc , vol.41 , pp. 28-33
    • Phillips, R.W.1    Biggs, D.H.2
  • 23
    • 0015014592 scopus 로고
    • Determination of the accuracy of wax interocclusal registrations
    • Millstein PL, Kronman JH, Clark RE: Determination of the accuracy of wax interocclusal registrations. J Prosthet Dent 1971;25:189-196
    • (1971) J Prosthet Dent , vol.25 , pp. 189-196
    • Millstein, P.L.1    Kronman, J.H.2    Clark, R.E.3
  • 24
    • 0015535106 scopus 로고
    • Determination of the accuracy of wax interocclusal registrations. II
    • Millstein PL, Clark RE, Kronman JH: Determination of the accuracy of wax interocclusal registrations. II. J Prosthet Dent 1973;29:40-45
    • (1973) J Prosthet Dent , vol.29 , pp. 40-45
    • Millstein, P.L.1    Clark, R.E.2    Kronman, J.H.3
  • 25
    • 0020825101 scopus 로고
    • Determination of the accuracy of laminated wax interocclusal wafers
    • Millstein PL, Clark RE: Determination of the accuracy of laminated wax interocclusal wafers. J Prosthet Dent 1983;50:327-331
    • (1983) J Prosthet Dent , vol.50 , pp. 327-331
    • Millstein, P.L.1    Clark, R.E.2
  • 26
    • 0022136127 scopus 로고
    • Accuracy of laminated wax interocclusal wafers
    • Millstein PL: Accuracy of laminated wax interocclusal wafers. J Prosthet Dent 1985;54:574-577
    • (1985) J Prosthet Dent , vol.54 , pp. 574-577
    • Millstein, P.L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.