-
1
-
-
0037526501
-
Closed-loop control of propofol anaesthesia using bispectral index: performance assessment in patients receiving computer-controlled propofol and manually controlled remifentanyl infusions for minor surgery
-
COI: 1:STN:280:DC%2BD3s3ktlemug%3D%3D
-
Absalom, A.R., Kenny, G.N., 2003. Closed-loop control of propofol anaesthesia using bispectral index: performance assessment in patients receiving computer-controlled propofol and manually controlled remifentanyl infusions for minor surgery.Br J Anaesth,90(6):737–741. DOI: 10.1093/bja/aeg137
-
(2003)
Br J Anaesth
, vol.90
, Issue.6
, pp. 737-741
-
-
Absalom, A.R.1
Kenny, G.N.2
-
2
-
-
0027319267
-
Effective concentration 50 for propofol with and without 67% nitrous oxide
-
Davison, J.A., Macleod, A.D., Howie, J.C., 1993. Effective concentration 50 for propofol with and without 67% nitrous oxide.Acta Anesthesiologica Scandinavia,37:458–464. DOI: 10.1111/j.1399-6576.1993.tb03746.x
-
(1993)
Acta Anesthesiologica Scandinavia
, vol.37
, pp. 458-464
-
-
Davison, J.A.1
Macleod, A.D.2
Howie, J.C.3
-
3
-
-
0025891376
-
Arterial washing of halothane and isoflurane in young and elderly adult patients
-
COI: 1:STN:280:DyaK3M3jsVGhsA%3D%3D
-
Dwyer, R.C., Fee, J.P., Howard, P.J., 1991. Arterial washing of halothane and isoflurane in young and elderly adult patients.Br J Anesth,66:572–579. DOI: 10.1093/bja/66.5.572
-
(1991)
Br J Anesth
, vol.66
, pp. 572-579
-
-
Dwyer, R.C.1
Fee, J.P.2
Howard, P.J.3
-
4
-
-
0026084833
-
Is the end-tidal partial pressure of isoflurane a good predictive of arterial partial pressure?
-
COI: 1:STN:280:DyaK3M7pslKgug%3D%3D
-
Frei, F.J., Zbinden, A.M., Thomson, D.A., 1991. Is the end-tidal partial pressure of isoflurane a good predictive of arterial partial pressure?Br J Anesth,66:331–339. DOI: 10.1093/bja/66.3.331
-
(1991)
Br J Anesth
, vol.66
, pp. 331-339
-
-
Frei, F.J.1
Zbinden, A.M.2
Thomson, D.A.3
-
5
-
-
0023605241
-
Disposition of propofol administered as constant rate intravenous infusions in humans
-
COI: 1:CAS:528:DyaL1cXkvVKksQ%3D%3D
-
Gepts, E., Camu, F., Cockshott, I.D., 1987. Disposition of propofol administered as constant rate intravenous infusions in humans.Anaesth and Analg,66:1256–1263. DOI: 10.1213/00000539-198712000-00010
-
(1987)
Anaesth and Analg
, vol.66
, pp. 1256-1263
-
-
Gepts, E.1
Camu, F.2
Cockshott, I.D.3
-
6
-
-
0002023122
-
Intravenous Drug Delivery
-
Milder R.D., (ed), 3rd Ed., Churchill Livingstone, New York
-
Glass, P.J., Jacobs, J.R., Reeves, J.G., 1990. Intravenous Drug Delivery.In: Milder, R.D. (Ed.), Anesthesia, 3rd Ed. Churchill Livingstone, New York, p.367–388.
-
(1990)
Anesthesia
, pp. 367-388
-
-
Glass, P.J.1
Jacobs, J.R.2
Reeves, J.G.3
-
7
-
-
0031837001
-
Development of ‘Diprifusor’: a TCI system for propofol
-
COI: 1:CAS:528:DyaK1cXis1Cqtro%3D
-
Glen, J.B., 1998. Development of ‘Diprifusor’: a TCI system for propofol.Anesthesia,53(suppl 1):13–21. DOI: 10.1111/j.1365-2044.1998.53s115.x
-
(1998)
Anesthesia
, vol.53
, pp. 13-21
-
-
Glen, J.B.1
-
8
-
-
12444330942
-
Population pharmacokinetics of propofol in Chinese patients
-
COI: 1:CAS:528:DC%2BD3sXkvFShtr8%3D, PID: 12791186
-
Li, Y.H., Rui, J.Z., 2003. Population pharmacokinetics of propofol in Chinese patients.Acta Pharmacol Sin,24(6):581–588.
-
(2003)
Acta Pharmacol Sin
, vol.24
, Issue.6
, pp. 581-588
-
-
Li, Y.H.1
Rui, J.Z.2
-
9
-
-
0025908613
-
Pharmacokinetic model driven infusion of propofol in children
-
COI: 1:STN:280:DyaK3MzhsF2iuw%3D%3D
-
Marsh, B., White, M., Morton, M., 1991. Pharmacokinetic model driven infusion of propofol in children.Br J Anesth,67:41–48. DOI: 10.1093/bja/67.1.41
-
(1991)
Br J Anesth
, vol.67
, pp. 41-48
-
-
Marsh, B.1
White, M.2
Morton, M.3
-
10
-
-
0037311828
-
Predictive performance of computer-controlled infusion of remifentanyl during propofol/remifentanyl anaesthesia
-
COI: 1:CAS:528:DC%2BD3sXit1Gqs7w%3D
-
Mertens, M.J., Engbers, F.H., Burm, A.G., Vuyk, J., 2003. Predictive performance of computer-controlled infusion of remifentanyl during propofol/remifentanyl anaesthesia.Br J Anaesth,90(2):132–141. DOI: 10.1093/bja/aeg046
-
(2003)
Br J Anaesth
, vol.90
, Issue.2
, pp. 132-141
-
-
Mertens, M.J.1
Engbers, F.H.2
Burm, A.G.3
Vuyk, J.4
-
11
-
-
0023232817
-
Improved method for the determination of propofol in blood by high-performance liquid chromatography with fluorescence detection
-
COI: 1:CAS:528:DyaL2sXmt1ygsLs%3D
-
Plummer, G.F., 1987. Improved method for the determination of propofol in blood by high-performance liquid chromatography with fluorescence detection.J Chromatogr, {Bd421}:171–176. DOI: 10.1016/0378-4347(87)80394-8
-
(1987)
J Chromatogr
, vol.421
, pp. 171-176
-
-
Plummer, G.F.1
-
12
-
-
17544387018
-
Population pharmacokinetics of propofol
-
COI: 1:CAS:528:DC%2BD3cXitVCrt7w%3D
-
Schuttler, J., Ihmsen, H., 2000. Population pharmacokinetics of propofol.Anesthesiology,92:727–738. DOI: 10.1097/00000542-200003000-00017
-
(2000)
Anesthesiology
, vol.92
, pp. 727-738
-
-
Schuttler, J.1
Ihmsen, H.2
-
13
-
-
0031862193
-
Evaluation of the predictive performance of a ‘Diprifusor’ TCI system
-
COI: 1:CAS:528:DyaK1cXis1Cqt70%3D
-
Swinhoe, C.F., Peacock, J.E., Glen, J.B., 1998. Evaluation of the predictive performance of a ‘Diprifusor’ TCI system.Anesthesia,53(Supp l):61–67. DOI: 10.1111/j.1365-2044.1998.53s104.x
-
(1998)
Anesthesia
, vol.53
, pp. 61-67
-
-
Swinhoe, C.F.1
Peacock, J.E.2
Glen, J.B.3
-
14
-
-
0026764580
-
Measuring the predictive performance of computer-controlled infusion pumps
-
COI: 1:CAS:528:DyaK38Xis1anu7Y%3D
-
Varvel, J.R., Donoho, D.L., Shafer, S.L, 1992. Measuring the predictive performance of computer-controlled infusion pumps.J Pharmacokin Biopharm,20:63–94. DOI: 10.1007/BF01143186
-
(1992)
J Pharmacokin Biopharm
, vol.20
, pp. 63-94
-
-
Varvel, J.R.1
Donoho, D.L.2
Shafer, S.L.3
|