메뉴 건너뛰기




Volumn 13, Issue 4, 2004, Pages 214-220

Influence of attachment systems on load transfer of an implant-assisted maxillary overdenture

Author keywords

Occlusion; Photoelastic analysis; Stress distribution

Indexed keywords

ARTICLE; COMPARATIVE STUDY; COMPRESSIVE STRENGTH; DENTAL CARE; DENTURE; HUMAN; INSTRUMENTATION; MAXILLOFACIAL PROSTHESIS; METHODOLOGY; TOOTH PROSTHESIS; WEIGHT BEARING;

EID: 16644388455     PISSN: 1059941X     EISSN: 1532849X     Source Type: Journal    
DOI: 10.1111/j.1532-849X.2004.04041.x     Document Type: Article
Times cited : (44)

References (14)
  • 2
    • 0030178783 scopus 로고    scopus 로고
    • In vitro study of mandibular implant-retained overdentures: The influence of stud attachments on load transfer to the implant and soft tissue
    • Ichikawa T, Horiuchi M, Wigianto R, et al: In vitro study of mandibular implant-retained overdentures: The influence of stud attachments on load transfer to the implant and soft tissue. Int J Prosthodont 1996;9:394-399
    • (1996) Int J Prosthodont , vol.9 , pp. 394-399
    • Ichikawa, T.1    Horiuchi, M.2    Wigianto, R.3
  • 3
    • 0032109199 scopus 로고    scopus 로고
    • Treatment concept for mandibular overdentures supported by endosseous implants: A literature review
    • Batenburg RH, Meijer HJ, Raghoebar GM, et al: Treatment concept for mandibular overdentures supported by endosseous implants: A literature review. Int J Oral Maxillofac Implants 1998;13:539-545
    • (1998) Int J Oral Maxillofac Implants , vol.13 , pp. 539-545
    • Batenburg, R.H.1    Meijer, H.J.2    Raghoebar, G.M.3
  • 4
    • 0031644610 scopus 로고    scopus 로고
    • Treatment of the atrophic edentulous maxilla with implant-supported overdentures: A review of the literature
    • Chan MF, Närhi TO, de Baat C, et al: Treatment of the atrophic edentulous maxilla with implant-supported overdentures: A review of the literature. Int J Prosthodont 1998;11:7-15
    • (1998) Int J Prosthodont , vol.11 , pp. 7-15
    • Chan, M.F.1    Närhi, T.O.2    De Baat, C.3
  • 6
    • 0024031111 scopus 로고
    • A retrospective multicenter evaluation of osseointegrated implants supporting overdentures
    • Engquist B, Bergendal T, Kallus T, et al: A retrospective multicenter evaluation of osseointegrated implants supporting overdentures. Int J Oral Maxillofac Implants 1988;3:129-134
    • (1988) Int J Oral Maxillofac Implants , vol.3 , pp. 129-134
    • Engquist, B.1    Bergendal, T.2    Kallus, T.3
  • 7
    • 0026084439 scopus 로고
    • The excessive loss of Branemark fixtures in type IV bone: A 5-year analysis
    • Jaffin RA, Berman CL: The excessive loss of Branemark fixtures in type IV bone: A 5-year analysis. J Periodontol 1991;62:2-4
    • (1991) J Periodontol , vol.62 , pp. 2-4
    • Jaffin, R.A.1    Berman, C.L.2
  • 8
    • 0032017010 scopus 로고    scopus 로고
    • Implant-supported overdentures: A longitudinal prospective study
    • Bergendal T, Engquist B: Implant-supported overdentures: A longitudinal prospective study. Int J Oral Maxillofac Implants 1998;13:253-262
    • (1998) Int J Oral Maxillofac Implants , vol.13 , pp. 253-262
    • Bergendal, T.1    Engquist, B.2
  • 10
    • 0030337833 scopus 로고    scopus 로고
    • Effects of overdenture retention designs and implant orientations on load transfer characteristics
    • Federick DR, Caputo AA: Effects of overdenture retention designs and implant orientations on load transfer characteristics. J Prosthet Dent 1996;76:624-632
    • (1996) J Prosthet Dent , vol.76 , pp. 624-632
    • Federick, D.R.1    Caputo, A.A.2
  • 11
    • 0026161040 scopus 로고
    • Prosthetic aspects of osseointegrated fixtures supporting overdentures. A 4-year report
    • Naert I, Quirynen M, Theuniers G, et al: Prosthetic aspects of osseointegrated fixtures supporting overdentures. A 4-year report. J Prosthet Dent 1991;65:671-680
    • (1991) J Prosthet Dent , vol.65 , pp. 671-680
    • Naert, I.1    Quirynen, M.2    Theuniers, G.3
  • 12
    • 0026921680 scopus 로고
    • Fixture design and overload influence marginal bone loss and fixture success in the Branemark system
    • Quirynen M, Naert I, van Steenberghe D: Fixture design and overload influence marginal bone loss and fixture success in the Branemark system. Clin Oral Implants Res 1992;3:104-111
    • (1992) Clin Oral Implants Res , vol.3 , pp. 104-111
    • Quirynen, M.1    Naert, I.2    Van Steenberghe, D.3
  • 13
    • 0028395085 scopus 로고
    • Implant-supported maxillary overdentures: Outcome in planned and emergency cases
    • Palmqvist S, Sondell K, Swartz B: Implant-supported maxillary overdentures: Outcome in planned and emergency cases. Int J Oral Maxillofac Implants 1994;9:184-190
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 184-190
    • Palmqvist, S.1    Sondell, K.2    Swartz, B.3
  • 14
    • 0032088918 scopus 로고    scopus 로고
    • Biological factors contributing to failures of osseointegrated oral implants. (II). Etiopathogenesis
    • Esposito M, Hirsch JM, Lekholm U, et al: Biological factors contributing to failures of osseointegrated oral implants. (II). Etiopathogenesis. Eur J Oral Sci 1998;106:721-764
    • (1998) Eur J Oral Sci , vol.106 , pp. 721-764
    • Esposito, M.1    Hirsch, J.M.2    Lekholm, U.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.