Volumn 429, Issue , 2004, Pages 39-42

Presidential Guest Address: Conquest of a worldwide human disease - Particle-induced periprosthetic osteolysis

Author keywords

[No Author keywords available]

Indexed keywords

CONFERENCE PAPER; MOLECULAR BIOLOGY; OSTEOLYSIS; PRIORITY JOURNAL; PROPHYLAXIS; PROSTHESIS; SURGICAL TECHNIQUE; TOTAL HIP PROSTHESIS; ARTHROPLASTY; ARTICLE; FEMALE; HEALTH; HUMAN; IATROGENIC DISEASE; INFECTION; JOINT PROSTHESIS; MALE; METHODOLOGY; PREVALENCE; PROGNOSIS; RISK ASSESSMENT;

EID: 16644386525     PISSN: 0009921X     EISSN: 15281132     Source Type: Journal    
DOI: 10.1097/01.blo.0000149821.72760.39     Document Type: Conference Paper
Times cited : (57)

References (30)
  • 1
    • 0029809897 scopus 로고    scopus 로고
    • Metal-on-metal total hip replacement workshop consensus document
    • Amstutz HC, Campbell P, McKellop H, et al: Metal-on-metal total hip replacement workshop consensus document. Clin Orthop 329(Suppl):S297-S303, 1996.
    • (1996) Clin Orthop , vol.329 , Issue.SUPPL.
    • Amstutz, H.C.1    Campbell, P.2    McKellop, H.3
  • 5
    • 0014351948 scopus 로고
    • The long-term reaction of bone to self-curing acrylic cement
    • Charnley J, Follacci F, Hammond B: The long-term reaction of bone to self-curing acrylic cement. J Bone Joint Surg 50B:822-829, 1968.
    • (1968) J Bone Joint Surg , vol.50 B , pp. 822-829
    • Charnley, J.1    Follacci, F.2    Hammond, B.3
  • 6
    • 0029989624 scopus 로고    scopus 로고
    • Early failure of Hylamer acetabular inserts due to eccentric wear
    • Chmell M, Poss R, Thomas WH, Sledge CB: Early failure of Hylamer acetabular inserts due to eccentric wear. J Arthroplasty 11:351-353, 1996.
    • (1996) J Arthroplasty , vol.11 , pp. 351-353
    • Chmell, M.1    Poss, R.2    Thomas, W.H.3    Sledge, C.B.4
  • 7
    • 0033401399 scopus 로고    scopus 로고
    • The Harris-Galante uncemented femoral component in primary total hip replacement at 10 years
    • Clohisy JC, Harris WH: The Harris-Galante uncemented femoral component in primary total hip replacement at 10 years. J Arthroplasty 14:915-917, 1999.
    • (1999) J Arthroplasty , vol.14 , pp. 915-917
    • Clohisy, J.C.1    Harris, W.H.2
  • 8
    • 9644254123 scopus 로고    scopus 로고
    • Highly cross-linked polyethylene in total hip arthroplasty: Clinical performance in cemented and uncemented sockets
    • Digas G, Karrholm J, Thanner J, Malchau H, Herberts P: Highly cross-linked polyethylene in total hip arthroplasty: Clinical performance in cemented and uncemented sockets. Clin Orthop 429:6-16, 2004.
    • (2004) Clin Orthop , vol.429 , pp. 6-16
    • Digas, G.1    Karrholm, J.2    Thanner, J.3    Malchau, H.4    Herberts, P.5
  • 9
    • 0034082534 scopus 로고    scopus 로고
    • Total hip arthroplasty with use of the metasul metal-on-metal articulation. Four- to seven-year results
    • Dorr LD, Wan Z, Longjohn DB, Dubois B, Murken R: Total hip arthroplasty with use of the metasul metal-on-metal articulation. Four- to seven-year results. J Bone Joint Surg 82:789-798, 2000.
    • (2000) J Bone Joint Surg , vol.82 , pp. 789-798
    • Dorr, L.D.1    Wan, Z.2    Longjohn, D.B.3    Dubois, B.4    Murken, R.5
  • 11
    • 0022510812 scopus 로고
    • Formation of a synovial-like membrane at the bone-cement interface. Its role in bone resorption and implant loosening after total hip replacement
    • Goldring S, Jasty M, Roelke M, et al: Formation of a synovial-like membrane at the bone-cement interface. Its role in bone resorption and implant loosening after total hip replacement. Arthritis Rheum 29:836-842, 1986.
    • (1986) Arthritis Rheum , vol.29 , pp. 836-842
    • Goldring, S.1    Jasty, M.2    Roelke, M.3
  • 12
    • 0020576705 scopus 로고
    • The synovial-like membrane at the bone-cement interface in loose total hip replacements and its proposed role in bone lysis
    • Goldring S, Schiller A, Roelke M, et al: The synovial-like membrane at the bone-cement interface in loose total hip replacements and its proposed role in bone lysis. J Bone Joint Surg 65A:575-584, 1983.
    • (1983) J Bone Joint Surg , vol.65 A , pp. 575-584
    • Goldring, S.1    Schiller, A.2    Roelke, M.3
  • 13
    • 0001379590 scopus 로고    scopus 로고
    • Clinical experience with gamma irradiation-crosslinked polyethylene - A 14 to 20 year follow-up report
    • Grobbelaar CJ, Weger FA, Spirakis A, et al: Clinical experience with gamma irradiation-crosslinked polyethylene - A 14 to 20 year follow-up report. South African Bone and Joint Surgery X1:140-147, 1999.
    • (1999) South African Bone and Joint Surgery , vol.11 , pp. 140-147
    • Grobbelaar, C.J.1    Weger, F.A.2    Spirakis, A.3
  • 16
    • 0028325196 scopus 로고
    • Osteolysis and particle disease in hip replacement. A review
    • Harris WH: Osteolysis and particle disease in hip replacement. A review. Acta Orthop Scand 65:113-123, 1994.
    • (1994) Acta Orthop Scand , vol.65 , pp. 113-123
    • Harris, W.H.1
  • 17
    • 0004185615 scopus 로고    scopus 로고
    • The problem is osteolysis
    • Harris WH: The problem is osteolysis. J Biomed Mater Res 31:19-26, 1996.
    • (1996) J Biomed Mater Res , vol.31 , pp. 19-26
    • Harris, W.H.1
  • 19
    • 0032816605 scopus 로고    scopus 로고
    • Omnifit cementless total hip arthroplasty. A 10-year average followup
    • Hellman EJ, Capello WN, Feinberg JR: Omnifit cementless total hip arthroplasty. A 10-year average followup. Clin Orthop 364:164-174, 1999.
    • (1999) Clin Orthop , vol.364 , pp. 164-174
    • Hellman, E.J.1    Capello, W.N.2    Feinberg, J.R.3
  • 20
    • 0032877442 scopus 로고    scopus 로고
    • Wear rates of ceramic-on-ceramic bearing surfaces in total hip implants: A 12-year follow-up study
    • Jazrawi LM, Bogner E, Della Valle CJ, et al: Wear rates of ceramic-on-ceramic bearing surfaces in total hip implants: A 12-year follow-up study. J Arthroplasty 14:781-787, 1999.
    • (1999) J Arthroplasty , vol.14 , pp. 781-787
    • Jazrawi, L.M.1    Bogner, E.2    Della Valle, C.J.3
  • 21
    • 0013912485 scopus 로고
    • Replacement of arthritic hips by the McKee- Farrar prosthesis
    • McKee GK, Watson-Farrar J: Replacement of arthritic hips by the McKee- Farrar prosthesis. J Bone Joint Surg 48B:245-259, 1966.
    • (1966) J Bone Joint Surg , vol.48 B , pp. 245-259
    • McKee, G.K.1    Watson-Farrar, J.2
  • 22
    • 0032927112 scopus 로고    scopus 로고
    • Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements
    • McKellop H: Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements. J Orthop Res 17:157-167, 1999.
    • (1999) J Orthop Res , vol.17 , pp. 157-167
    • McKellop, H.1
  • 23
    • 0035117295 scopus 로고    scopus 로고
    • A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. Recipient of the 1999 HAP Paul Award
    • Muratoglu OK, Bragdon CR, O'Connor DO, Jasty M, Harris WH: A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. Recipient of the 1999 HAP Paul Award. J Arthroplasty 16:149-160, 2001.
    • (2001) J Arthroplasty , vol.16 , pp. 149-160
    • Muratoglu, O.K.1    Bragdon, C.R.2    O'Connor, D.O.3    Jasty, M.4    Harris, W.H.5
  • 25
    • 0002389233 scopus 로고    scopus 로고
    • Clinical tribological performance of 144 metal-on-metal hip articulations
    • Ricker W, Wyss U (eds). Bern, Switzerland: Hans Huber
    • Rieker CB, Kottig P, Schon R, Windler M, Wyss UP: Clinical Tribological Performance of 144 Metal-on-metal Hip Articulations. In Ricker W, Wyss U (eds). Metasul: A Metal-on-Metal Bearing. Bern, Switzerland: Hans Huber 83-91, 1999.
    • (1999) Metasul: A Metal-on-Metal Bearing , pp. 83-91
    • Rieker, C.B.1    Kottig, P.2    Schon, R.3    Windler, M.4    Wyss, U.P.5
  • 26
    • 0026550544 scopus 로고
    • The mechanism of loosening of cemented acetabular components in total hip arthroplasty. Analysis of specimens retrieved at autopsy
    • Schmalzried TP, Kwong LM, Jasty M, et al: The mechanism of loosening of cemented acetabular components in total hip arthroplasty. Analysis of specimens retrieved at autopsy. Clin Orthop 274:60-78, 1992.
    • (1992) Clin Orthop , vol.274 , pp. 60-78
    • Schmalzried, T.P.1    Kwong, L.M.2    Jasty, M.3
  • 27
    • 0002775461 scopus 로고
    • Tissue reactions to plastic and metallic wear products of joint endoprostheses
    • New York: Springer-Verlag, Berlin Heidelberg
    • Willert HG, Semlitsch M: Tissue reactions to plastic and metallic wear products of joint endoprostheses. In Total Hip Prosthesis. New York: Springer-Verlag, Berlin Heidelberg 1976.
    • (1976) Total Hip Prosthesis
    • Willert, H.G.1    Semlitsch, M.2
  • 28
    • 0017462028 scopus 로고
    • Reactions of the articular capsule to wear products of artificial joint prostheses
    • Willert HG: Reactions of the articular capsule to wear products of artificial joint prostheses. J Biomed Mater Res 11:157-164, 1977.
    • (1977) J Biomed Mater Res , vol.11 , pp. 157-164
    • Willert, H.G.1
  • 29
    • 0032922181 scopus 로고    scopus 로고
    • Low-friction arthroplasty of the hip using alumina ceramic and cross-linked polyethylene. A ten-year follow-up report
    • Wroblewski BM: Low-friction arthroplasty of the hip using alumina ceramic and cross-linked polyethylene. A ten-year follow-up report. J Bone Joint Surg 81B:54-55, 1999.
    • (1999) J Bone Joint Surg , vol.81 B , pp. 54-55
    • Wroblewski, B.M.1
  • 30
    • 0028956936 scopus 로고
    • Patterns of osteolysis around total hip components inserted with and without cement
    • Zicat B, Engh C, Gokcen E: Patterns of osteolysis around total hip components inserted with and without cement. J Bone Joint Surg 77A:432-439, 1995.
    • (1995) J Bone Joint Surg , vol.77 A , pp. 432-439
    • Zicat, B.1    Engh, C.2    Gokcen, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.