-
1
-
-
0024409531
-
Parapapillary retinal vessel diameter in normal and glaucoma eyes. I. Morphometric data
-
J. B. Jonas, X. N. Nguyen, and G. O. Naumann, "Parapapillary retinal vessel diameter in normal and glaucoma eyes. I. Morphometric data," Invest. Ophthalmol. Visual Sci. 30, 1599-1603 (1989).
-
(1989)
Invest. Ophthalmol. Visual Sci.
, vol.30
, pp. 1599-1603
-
-
Jonas, J.B.1
Nguyen, X.N.2
Naumann, G.O.3
-
2
-
-
0027408124
-
Retinal hemodynamics in proliferative diabetic retinopathy. a laser Doppler velocimetry study
-
J. E. Grunwald, A. J. Brucker, S. E. Grunwald, and C. E. Riva, "Retinal hemodynamics in proliferative diabetic retinopathy. A laser Doppler velocimetry study," Invest. Ophthalmol. Visual Sci. 34, 66-71 (1993).
-
(1993)
Invest. Ophthalmol. Visual Sci.
, vol.34
, pp. 66-71
-
-
Grunwald, J.E.1
Brucker, A.J.2
Grunwald, S.E.3
Riva, C.E.4
-
3
-
-
0034866379
-
Retinal microvascular abnormalities and their relationship with hypertension, cardiovascular disease, and mortality
-
T. Y. Wong, R. Klein, B. E. Klein, J. M. Tielsch, L. Hubbard, and F. J. Nieto, "Retinal microvascular abnormalities and their relationship with hypertension, cardiovascular disease, and mortality," Surv. Ophthalmol. 46, 59-80 (2001).
-
(2001)
Surv. Ophthalmol.
, vol.46
, pp. 59-80
-
-
Wong, T.Y.1
Klein, R.2
Klein, B.E.3
Tielsch, J.M.4
Hubbard, L.5
Nieto, F.J.6
-
4
-
-
0033503919
-
Methods for evaluation of retinal microvascular abnormalities associated with hypertension/sclerosis in the Atherosclerosis Risk in Communities (ARIC) Study
-
L. D. Hubbard, R. J. Brothers, W. N. King, L. X. Clegg, R. Klein, L. S. Cooper, A. R. Sharrett, M. D. Davis, and J. Cai, "Methods for evaluation of retinal microvascular abnormalities associated with hypertension/sclerosis in the Atherosclerosis Risk in Communities (ARIC) Study," Ophthalmology 106, 2269-2280 (1999).
-
(1999)
Ophthalmology
, vol.106
, pp. 2269-2280
-
-
Hubbard, L.D.1
Brothers, R.J.2
King, W.N.3
Clegg, L.X.4
Klein, R.5
Cooper, L.S.6
Sharrett, A.R.7
Davis, M.D.8
Cai, J.9
-
5
-
-
0345863722
-
Variation associated with measurement of retinal vessel diameters at different points in the pulse cycle
-
M. D. Knudtson, B. E. Klein, R. Klein, T. Y. Wong, L. D. Hubbard, K. E. Lee, S. M. Meuer, and C. P. Bulla, "Variation associated with measurement of retinal vessel diameters at different points in the pulse cycle," Br. J. Ophthalmol. 88, 57-61 (2004).
-
(2004)
Br. J. Ophthalmol.
, vol.88
, pp. 57-61
-
-
Knudtson, M.D.1
Klein, B.E.2
Klein, R.3
Wong, T.Y.4
Hubbard, L.D.5
Lee, K.E.6
Meuer, S.M.7
Bulla, C.P.8
-
6
-
-
0028209626
-
Vessel diameter changes during the cardiac cycle
-
H. C. Chen, V. Patel, J. Wiek, S. M. Rassam, and E. M. Kohner, "Vessel diameter changes during the cardiac cycle," Eye 8, 97-103 (1994).
-
(1994)
Eye
, vol.8
, pp. 97-103
-
-
Chen, H.C.1
Patel, V.2
Wiek, J.3
Rassam, S.M.4
Kohner, E.M.5
-
7
-
-
0029795912
-
The accurate assessment of changes in retinal vessel diameter using multiple frame electrocardiograph synchronised fundus photography
-
M. J. Dumskyj, S. J. Aldington, C. J. Dore, and E. M. Kohner, "The accurate assessment of changes in retinal vessel diameter using multiple frame electrocardiograph synchronised fundus photography," Curr. Eye. Res. 15, 625-632 (1996).
-
(1996)
Curr. Eye. Res.
, vol.15
, pp. 625-632
-
-
Dumskyj, M.J.1
Aldington, S.J.2
Dore, C.J.3
Kohner, E.M.4
-
8
-
-
0024600652
-
Reliable measurements from fundus photographs in the presence of focusing errors
-
H. Heier and O. Brinchmann-Hansen, "Reliable measurements from fundus photographs in the presence of focusing errors," Invest. Ophthalmol. Visual Sci. 30, 674-677 (1989).
-
(1989)
Invest. Ophthalmol. Visual Sci.
, vol.30
, pp. 674-677
-
-
Heier, H.1
Brinchmann-Hansen, O.2
-
9
-
-
0036156161
-
Detection and measurement of retinal vessels in fundus images using amplitude modified second-order Gaussian filter
-
L. Gang, O. Chutatpe, and S. M. Krishnan, "Detection and measurement of retinal vessels in fundus images using amplitude modified second-order Gaussian filter," IEEE Trans. Biomed. Eng. 49, 168-172 (2002).
-
(2002)
IEEE Trans. Biomed. Eng.
, vol.49
, pp. 168-172
-
-
Gang, L.1
Chutatpe, O.2
Krishnan, S.M.3
-
10
-
-
0035175539
-
Computer algorithms for the automated measurement of retinal arteriolar diameters
-
N. Chapman, N. Witt, X. Gao, A. A. Bharath, A. V. Stanton, S. A. Thom, and A. D. Hughes, "Computer algorithms for the automated measurement of retinal arteriolar diameters," Br. J. Ophthalmol. 85, 74-79 (2001).
-
(2001)
Br. J. Ophthalmol.
, vol.85
, pp. 74-79
-
-
Chapman, N.1
Witt, N.2
Gao, X.3
Bharath, A.A.4
Stanton, A.V.5
Thom, S.A.6
Hughes, A.D.7
-
11
-
-
0024734454
-
Detection of blood vessels in retinal images using two-dimensional matched filters
-
S. Chaudhuri, S. Chatterjee, N. Katz, and M. Goldbaum, "Detection of blood vessels in retinal images using two-dimensional matched filters," IEEE Trans. Med. Imaging 8, 263-269 (1989).
-
(1989)
IEEE Trans. Med. Imaging
, vol.8
, pp. 263-269
-
-
Chaudhuri, S.1
Chatterjee, S.2
Katz, N.3
Goldbaum, M.4
-
12
-
-
0033623974
-
Locating blood vessels in retinal images by piecewise threshold probing of a matched filter response
-
A. Hoover, V. Kouznetsova, and M. Goldbaum, "Locating blood vessels in retinal images by piecewise threshold probing of a matched filter response," IEEE Trans. Med. Imaging 19, 203-210 (2000).
-
(2000)
IEEE Trans. Med. Imaging
, vol.19
, pp. 203-210
-
-
Hoover, A.1
Kouznetsova, V.2
Goldbaum, M.3
-
13
-
-
1642287992
-
A model based method for retinal blood vessel detection
-
K. A. Vermeer, F. M. Vos, H. G. Lemij, and A. M. Vossepoel, "A model based method for retinal blood vessel detection," Comp. Biol. Med. 34, 209-219 (2004).
-
(2004)
Comp. Biol. Med.
, vol.34
, pp. 209-219
-
-
Vermeer, K.A.1
Vos, F.M.2
Lemij, H.G.3
Vossepoel, A.M.4
-
15
-
-
0032921026
-
Is cooperative oxygen binding by hemoglobin really understood?
-
W. A. Eaton, E. R. Henry, J. Hofrichter, and A. Mozzarelli, "Is cooperative oxygen binding by hemoglobin really understood?" Nat. Struct. Biol. 6, 351-358 (1999).
-
(1999)
Nat. Struct. Biol.
, vol.6
, pp. 351-358
-
-
Eaton, W.A.1
Henry, E.R.2
Hofrichter, J.3
Mozzarelli, A.4
-
16
-
-
0014826291
-
Absorption and multiple scattering by biological suspensions
-
V. Twersky, "Absorption and multiple scattering by biological suspensions," J. Opt. Soc. Am. 60, 1084-1093 (1970).
-
(1970)
J. Opt. Soc. Am.
, vol.60
, pp. 1084-1093
-
-
Twersky, V.1
-
17
-
-
0000256333
-
Effect of multiple light paths on retinal vessel oximetry
-
M. H. Smith, K. R. Denninghoff, A. Lompado, and L. W. Hillman, "Effect of multiple light paths on retinal vessel oximetry," Appl. Opt. 39, 1183-1193 (2000).
-
(2000)
Appl. Opt.
, vol.39
, pp. 1183-1193
-
-
Smith, M.H.1
Denninghoff, K.R.2
Lompado, A.3
Hillman, L.W.4
-
18
-
-
0035029105
-
Light paths in retinal vessel oxymetry
-
M. Hammer, S. Leistritz, L. Leistritz, and D. Schweitzer, "Light paths in retinal vessel oxymetry," IEEE Trans. Biomed. Eng. 48, 592-598 (2001).
-
(2001)
IEEE Trans. Biomed. Eng.
, vol.48
, pp. 592-598
-
-
Hammer, M.1
Leistritz, S.2
Leistritz, L.3
Schweitzer, D.4
|