메뉴 건너뛰기




Volumn 22, Issue 2, 2005, Pages 134-138

The use of metal or plastic needles in continuous subcutaneous infusion in a hospice setting

Author keywords

Continuous subcutaneous infusion; Hospice; Plastic needles; Syringe driver

Indexed keywords

CYCLIZINE; DEXAMETHASONE; DIAMORPHINE; DICLOFENAC; GLYCOPYRRONIUM BROMIDE; HALOPERIDOL; LEVOMEPROMAZINE; METAL; METOCLOPRAMIDE; MIDAZOLAM; OCTREOTIDE; PLASTIC; SCOPOLAMINE BROMIDE; SCOPOLAMINE BUTYL BROMIDE;

EID: 16444372836     PISSN: 10499091     EISSN: None     Source Type: Journal    
DOI: 10.1177/104990910502200211     Document Type: Article
Times cited : (2)

References (11)
  • 1
    • 0018632211 scopus 로고
    • Slow drug infusions using a portable syringe driver
    • Wright BM, Callan K: Slow drug infusions using a portable syringe driver. Br Med J. 1979; 2(6190): 582.
    • (1979) Br Med J , vol.2 , Issue.6190 , pp. 582
    • Wright, B.M.1    Callan, K.2
  • 2
    • 0018427936 scopus 로고
    • Analgesia in terminal malignant disease
    • Russell PS: Analgesia in terminal malignant disease. Br Med J. 1979; 1(6177): 1561.
    • (1979) Br Med J , vol.1 , Issue.6177 , pp. 1561
    • Russell, P.S.1
  • 3
    • 0038804676 scopus 로고    scopus 로고
    • Subcutaneous drug infusions: A review of problems and solutions
    • Mitten T: Subcutaneous drug infusions: A review of problems and solutions. Int J Palliat Nurs. 2001; 7(2): 75-85.
    • (2001) Int J Palliat Nurs , vol.7 , Issue.2 , pp. 75-85
    • Mitten, T.1
  • 4
    • 0008502658 scopus 로고    scopus 로고
    • An audit of subcutaneous syringe drivers in a non-specialist hospital
    • Dunne K, Sullivan K, Garvey A, et al.: An audit of subcutaneous syringe drivers in a non-specialist hospital. Int J Palliat Nurs. 2000; 6(5): 214-219.
    • (2000) Int J Palliat Nurs , vol.6 , Issue.5 , pp. 214-219
    • Dunne, K.1    Sullivan, K.2    Garvey, A.3
  • 5
    • 0025348290 scopus 로고
    • Comparison of Teflon cannulas and metal needles for subcutaneous infusion in terminal care: A pilot study
    • Youseef MS, Atkinson RE: Comparison of Teflon cannulas and metal needles for subcutaneous infusion in terminal care: A pilot study. BMJ. 1990; 300(6728): 847.
    • (1990) BMJ , vol.300 , Issue.6728 , pp. 847
    • Youseef, M.S.1    Atkinson, R.E.2
  • 6
    • 0036202375 scopus 로고    scopus 로고
    • A prospective, within-patient comparison between metal butterfly needles and Teflon cannulae in subcutaneous infusion of drugs to terminally ill hospice patients
    • Ross JR, Saunders Y, Cochrane M, et al.: A prospective, within-patient comparison between metal butterfly needles and Teflon cannulae in subcutaneous infusion of drugs to terminally ill hospice patients. Palliat Med. 2002; 16(1): 13-16.
    • (2002) Palliat Med , vol.16 , Issue.1 , pp. 13-16
    • Ross, J.R.1    Saunders, Y.2    Cochrane, M.3
  • 7
    • 0034149331 scopus 로고    scopus 로고
    • A randomized trial of winged Vialon cannulae and metal butterfly needles
    • Dawkins L, Britton D, Johnson I, et al.: A randomized trial of winged Vialon cannulae and metal butterfly needles. Int J Palliat Nurs. 2000; 6(3): 110-116.
    • (2000) Int J Palliat Nurs , vol.6 , Issue.3 , pp. 110-116
    • Dawkins, L.1    Britton, D.2    Johnson, I.3
  • 8
    • 0035088365 scopus 로고    scopus 로고
    • Drugs and syringe drivers: A survey of adult specialist palliative care practice in the United Kingdom and Eire
    • O'Doherty CA, Hall EJ, Schofield L, et al.: Drugs and syringe drivers: A survey of adult specialist palliative care practice in the United Kingdom and Eire. Palliat Med. 2001; 15(2): 149-154.
    • (2001) Palliat Med , vol.15 , Issue.2 , pp. 149-154
    • O'Doherty, C.A.1    Hall, E.J.2    Schofield, L.3
  • 9
    • 10744230948 scopus 로고    scopus 로고
    • Occupational exposures to blood and biological material in healthcare workers
    • EPINETAC project. 1996-2000
    • Hernandez Navarrete MJ, Campins MM, Martinez SE, et al.: Occupational exposures to blood and biological material in healthcare workers. EPINETAC project. 1996-2000. Med Clin (Barc). 2004; 122(3): 81-86.
    • (2004) Med Clin (Barc) , vol.122 , Issue.3 , pp. 81-86
    • Hernandez Navarrete, M.J.1    Campins, M.M.2    Martinez, S.E.3
  • 10
    • 1542428029 scopus 로고    scopus 로고
    • Raising awareness and reducing the risk of needlestick injuries
    • Trim JC: Raising awareness and reducing the risk of needlestick injuries. Prof Nurse. 2004 19(5): 259-264.
    • (2004) Prof Nurse , vol.19 , Issue.5 , pp. 259-264
    • Trim, J.C.1
  • 11
    • 0042388458 scopus 로고    scopus 로고
    • Management of healthcare workers after occupational exposure to hepatitis C virus
    • Charles PG, Angus PW, Sasadeusz JJ, et al.: Management of healthcare workers after occupational exposure to hepatitis C virus. Med J Aust. 2003; 179(3): 153-157.
    • (2003) Med J Aust , vol.179 , Issue.3 , pp. 153-157
    • Charles, P.G.1    Angus, P.W.2    Sasadeusz, J.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.