메뉴 건너뛰기




Volumn 42, Issue 1-9, 2004, Pages 459-463

Estimation of some transducer parameters in a broadband piezoelectric transmitter by using an artificial intelligence technique

Author keywords

Broadband; Estimation; Genetic algorithms; Piezoelectric transmitters; Transducer parameters

Indexed keywords

COMPUTER SIMULATION; GENETIC ALGORITHMS; PARAMETER ESTIMATION; PIEZOELECTRIC DEVICES; ULTRASONICS;

EID: 1642632774     PISSN: 0041624X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ultras.2003.12.034     Document Type: Conference Paper
Times cited : (17)

References (12)
  • 1
    • 0034224294 scopus 로고    scopus 로고
    • Improvement in transient piezoelectric responses of NDE transceivers using selective damping and tuning networks
    • Ramos A., San Emeterio J.L., Sanz P.T. Improvement in transient piezoelectric responses of NDE transceivers using selective damping and tuning networks. IEEE Trans. Ultrason. Ferroelectr. Freq. Control. 47(4):2000;826-835.
    • (2000) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.47 , Issue.4 , pp. 826-835
    • Ramos, A.1    San Emeterio, J.L.2    Sanz, P.T.3
  • 2
    • 0017017623 scopus 로고
    • Iterative method for accurate determination of the real and imaginary parts of the materials coefficients of piezoelectric ceramics
    • Smits J.G. Iterative method for accurate determination of the real and imaginary parts of the materials coefficients of piezoelectric ceramics. IEEE Trans. Son. Ultrason. SU-23(6):1976;393-402.
    • (1976) IEEE Trans. Son. Ultrason. , vol.SU-23 , Issue.6 , pp. 393-402
    • Smits, J.G.1
  • 5
    • 0031995234 scopus 로고    scopus 로고
    • Locations of continuous AE sources by sensory neural networks
    • Grabec I., Kosel T., Mužič P. Locations of continuous AE sources by sensory neural networks. Ultrasonics. 36:1998;525-530.
    • (1998) Ultrasonics , vol.36 , pp. 525-530
    • Grabec, I.1    Kosel, T.2    Mužič, P.3
  • 6
    • 0033237762 scopus 로고    scopus 로고
    • Maximum a posteriori deconvolution of sparse ultrasonic signals using genetic optimization
    • Olofsson T., Stepinski T. Maximum a posteriori deconvolution of sparse ultrasonic signals using genetic optimization. Ultrasonics. 37:1999;423-432.
    • (1999) Ultrasonics , vol.37 , pp. 423-432
    • Olofsson, T.1    Stepinski, T.2
  • 7
    • 0033311665 scopus 로고    scopus 로고
    • Improved ultrasonic image generation through tomographic image fusion
    • Hall I.D., McNab A., Hayward G. Improved ultrasonic image generation through tomographic image fusion. Ultrasonics. 37:1999;433-443.
    • (1999) Ultrasonics , vol.37 , pp. 433-443
    • Hall, I.D.1    Mcnab, A.2    Hayward, G.3
  • 8
    • 0342626595 scopus 로고    scopus 로고
    • The application of genetic algorithm to sensor parameter selection for multisensor array configuration
    • Corcoran P., Anglesea J., Elshaw M. The application of genetic algorithm to sensor parameter selection for multisensor array configuration. Sensor Actuator. 76:1999;57-66.
    • (1999) Sensor Actuator , vol.76 , pp. 57-66
    • Corcoran, P.1    Anglesea, J.2    Elshaw, M.3
  • 9
    • 1642626274 scopus 로고    scopus 로고
    • Genetic algorithm - Based estimation of non-linear transducer
    • Zheming Z., Weiji H. Genetic algorithm - based estimation of non-linear transducer. J. Southeast Univ. (Engl. Edn). 17(1):2001;1-4.
    • (2001) J. Southeast Univ. (Engl. Edn) , vol.17 , Issue.1 , pp. 1-4
    • Zheming, Z.1    Weiji, H.2
  • 10
    • 0342589566 scopus 로고
    • Una implementación del modelo KLM para transductores piezoeléctricos en modo espesor
    • San Emeterio J.L., Sanz P.T., Riera E., Ramos A. Una implementación del modelo KLM para transductores piezoeléctricos en modo espesor. An. Fis. B. 84:1988;11-19.
    • (1988) An. Fis. B , vol.84 , pp. 11-19
    • San Emeterio, J.L.1    Sanz, P.T.2    Riera, E.3    Ramos, A.4
  • 11
    • 0014796286 scopus 로고
    • New equivalent circuits for elementary piezoelectric transducers
    • Krimholtz R., Leedom F., Matthaei G. New equivalent circuits for elementary piezoelectric transducers. Electron. Lett. 6(13):1970;398-399.
    • (1970) Electron. Lett. , vol.6 , Issue.13 , pp. 398-399
    • Krimholtz, R.1    Leedom, F.2    Matthaei, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.