메뉴 건너뛰기




Volumn 10, Issue 6, 2003, Pages 994-1005

Liquid Rare Gas Detectors: Recent Developments and Applications

Author keywords

Dielectric liquids; Gamma ray detectors; Liquid argon; Liquid detectors; Liquid krypton; Liquid rare gases; Liquid xenon; Particle detectors; Radiation detectors

Indexed keywords

ARGON; ASTROPHYSICS; CALORIMETERS; CAMERAS; DIELECTRIC LIQUIDS; ELECTROMAGNETISM; GAMMA RAYS; IONIZATION; KRYPTON; MEDICAL IMAGING; PARTICLE DETECTORS; PHOTOMULTIPLIERS; SCINTILLATION; XENON;

EID: 1642526580     PISSN: 10709878     EISSN: None     Source Type: Journal    
DOI: 10.1109/TDEI.2003.1255777     Document Type: Conference Paper
Times cited : (12)

References (93)
  • 1
    • 1642458492 scopus 로고
    • On liquid argon ionization chambers of centimetre size
    • J.H. Marshall, "On liquid argon ionization chambers of centimetre size", Rev. Sci. Instrum., Vol. 25, pp. 232-237, 1954.
    • (1954) Rev. Sci. Instrum. , vol.25 , pp. 232-237
    • Marshall, J.H.1
  • 2
    • 0016104194 scopus 로고
    • Liquid argon ionization chambers as total-absorption detectors
    • W.I. Willis and V. Radeka, "Liquid argon ionization chambers as total-absorption detectors", Nucl. Instr. Meth., Vol. 120, pp. 221-236, 1974.
    • (1974) Nucl. Instr. Meth. , vol.120 , pp. 221-236
    • Willis, W.I.1    Radeka, V.2
  • 3
    • 0001785887 scopus 로고
    • Fundamental properties of liquid argon, krypton and xenon as radiation detector media
    • T. Doke, "Fundamental properties of liquid argon, krypton and xenon as radiation detector media", Portgal. Phys., Vol. 12, pp. 9-48, 1981.
    • (1981) Portgal. Phys. , vol.12 , pp. 9-48
    • Doke, T.1
  • 5
    • 0024112633 scopus 로고
    • Purification and purity control of working media for liquid ionization detectors
    • A. S. Barabash, "Purification and purity control of working media for liquid ionization detectors". Instr. Exp. Tech., Vol. 31, pp. 517-534, 1988.
    • (1988) Instr. Exp. Tech. , vol.31 , pp. 517-534
    • Barabash, A.S.1
  • 6
    • 0003338313 scopus 로고
    • A study of the factors affecting the electron lifetime in ultra-pure liquid argon
    • A. Bettini et al., "A study of the factors affecting the electron lifetime in ultra-pure liquid argon", Nucl. Instr. Meth., Vol. A 305, pp. 177-186, 1991.
    • (1991) Nucl. Instr. Meth. , vol.A 305 , pp. 177-186
    • Bettini, A.1
  • 7
    • 0006458384 scopus 로고
    • Measurement of the lifetime of conduction electrons in liquid xenon
    • E. Aprile, R. Mukherjee and M. Suzuki, "Measurement of the lifetime of conduction electrons in liquid xenon", Nucl. Instr. Meth., Vol. A 300, pp. 343-350, 1991.
    • (1991) Nucl. Instr. Meth. , vol.A 300 , pp. 343-350
    • Aprile, E.1    Mukherjee, R.2    Suzuki, M.3
  • 9
    • 0027557105 scopus 로고
    • Spark discharge method of liquid rare-gas purification
    • S.G. Pokachalov et al., "Spark discharge method of liquid rare-gas purification", Nucl. Instr. Meth., Vol. A 327, pp. 159-162, 1993.
    • (1993) Nucl. Instr. Meth. , vol.A 327 , pp. 159-162
    • Pokachalov, S.G.1
  • 10
    • 0030192318 scopus 로고    scopus 로고
    • A large liquid xenon time projection chamber for the study of the radiative pion decay
    • G. Carugno et al., "A large liquid xenon time projection chamber for the study of the radiative pion decay", Nucl. Instr. Meth., Vol. A 376, pp. 149-154, 1996.
    • (1996) Nucl. Instr. Meth. , vol.A 376 , pp. 149-154
    • Carugno, G.1
  • 12
    • 0001166554 scopus 로고    scopus 로고
    • Liquid helium and liquid neon sensitive, low background, scintillation media for the detection of low energy neutrinos
    • D.N. McKinsey and J.M. Doyle, "Liquid helium and liquid neon sensitive, low background, scintillation media for the detection of low energy neutrinos", J. Low Temp. Phys., Vol. 118, p. 153, 2000.
    • (2000) J. Low Temp. Phys. , vol.118 , pp. 153
    • McKinsey, D.N.1    Doyle, J.M.2
  • 13
    • 0032714754 scopus 로고    scopus 로고
    • Present status of liquid rare gas scintillation detectors and their application to gamma-ray calorimeters
    • T. Doke and K. Masuda, "Present status of liquid rare gas scintillation detectors and their application to gamma-ray calorimeters", Nucl. Instr. Meth., Vol. A 420, pp. 62-80, 1999.
    • (1999) Nucl. Instr. Meth. , vol.A 420 , pp. 62-80
    • Doke, T.1    Masuda, K.2
  • 16
    • 0019621114 scopus 로고
    • A liquid xenon position sensitive gamma-rav detector for positron annihilation experiments
    • K. Masuda, T. Doke and T. Takahashi, "A liquid xenon position sensitive gamma-rav detector for positron annihilation experiments", Nucl. Instr. Meth., Vol. 188, pp. 629-638, 1981.
    • (1981) Nucl. Instr. Meth. , vol.188 , pp. 629-638
    • Masuda, K.1    Doke, T.2    Takahashi, T.3
  • 19
    • 30244557810 scopus 로고
    • Mean energy of ion pair production in liquid and solid xenon
    • I.M- Obodovski and S.G. Pokachalov, "Mean energy of ion pair production in liquid and solid xenon", Sov. J. Low Temp. Phys., Vol. 5, pp. 829-836, 1979.
    • (1979) Sov. J. Low Temp. Phys. , vol.5 , pp. 829-836
    • Obodovski, I.M.1    Pokachalov, S.G.2
  • 22
    • 0016620204 scopus 로고
    • Drift velocities of electrons, saturation characteristics of ionisation and W-values for conversion electrons in liquid argon, argon-gas mixtures and liquid xenon
    • E. Shibamura, A. Hitachi, T. Doke, T. Takahashi, S. Kubota and M. Miyajima, "Drift velocities of electrons, saturation characteristics of ionisation and W-values for conversion electrons in liquid argon, argon-gas mixtures and liquid xenon", Nucl. Instr. Meth., Vol. 131, pp. 249-258, 1975.
    • (1975) Nucl. Instr. Meth. , vol.131 , pp. 249-258
    • Shibamura, E.1    Hitachi, A.2    Doke, T.3    Takahashi, T.4    Kubota, S.5    Miyajima, M.6
  • 23
    • 0023451848 scopus 로고
    • Energy resolution studies of liquid argon ionization detectors
    • E. Aprile, J. Park, H. Schwanz and W.H. Ku, "Energy resolution studies of liquid argon ionization detectors", Nucl. Instr. Meth., Vol. A261, pp. 519-526, 1987.
    • (1987) Nucl. Instr. Meth. , vol.A261 , pp. 519-526
    • Aprile, E.1    Park, J.2    Schwanz, H.3    Ku, W.H.4
  • 24
    • 0000039261 scopus 로고
    • Performance of a liquid xenon ionization chamber irradiated with electrons and gamma-rays
    • E. Aprile, R. Mukherjee and M. Suzuki, "Performance of a liquid xenon ionization chamber irradiated with electrons and gamma-rays", Nucl. Instr. Meth., Vol. A302, pp. 177-185, 1991.
    • (1991) Nucl. Instr. Meth. , vol.A302 , pp. 177-185
    • Aprile, E.1    Mukherjee, R.2    Suzuki, M.3
  • 25
    • 0037149276 scopus 로고    scopus 로고
    • Detection of gamma-rays with a 3.5 liter liquid xenon ionization chamber triggered by the primary scintillation light
    • E. Aprile, A. Bolotnikov, D. Chen, R. Mukherjee and F. Xu, "Detection of gamma-rays with a 3.5 liter liquid xenon ionization chamber triggered by the primary scintillation light", Nucl. Instr. Meth., Vol. A 480, pp. 636-650, 2002.
    • (2002) Nucl. Instr. Meth. , vol.A 480 , pp. 636-650
    • Aprile, E.1    Bolotnikov, A.2    Chen, D.3    Mukherjee, R.4    Xu, F.5
  • 26
    • 0027560038 scopus 로고
    • The supression of the slow component in xenon-doped liquid argon scintillation
    • S. Kubota, M. Hishida, S. Himi, M. Suzuki and J. Ruan(Gen), "The supression of the slow component in xenon-doped liquid argon scintillation", Nucl. Instr. Meth., Vol. A327, pp. 71-74, 1993.
    • (1993) Nucl. Instr. Meth. , vol.A327 , pp. 71-74
    • Kubota, S.1    Hishida, M.2    Himi, S.3    Suzuki, M.4    Ruan, J.5
  • 27
    • 0030284549 scopus 로고
    • Time behaviour of the scintillation light in mixtures of liquid argon and xenon
    • E. Conti, G. Carugno and A. Intravaia, "Time behaviour of the scintillation light in mixtures of liquid argon and xenon", Nucl. Instr. Meth., Vol. A382, pp. 475-478, 1993.
    • (1993) Nucl. Instr. Meth. , vol.A382 , pp. 475-478
    • Conti, E.1    Carugno, G.2    Intravaia, A.3
  • 34
    • 0036541310 scopus 로고    scopus 로고
    • Development of a liquid Xe photon detector for μ → eγ decay search experiment at PSI
    • S. Mihara et al., "Development of a liquid Xe photon detector for μ → eγ decay search experiment at PSI", IEEE Trans. Nucl. Sci., Vol. 49, pp. 588-591, 2002.
    • (2002) IEEE Trans. Nucl. Sci. , vol.49 , pp. 588-591
    • Mihara, S.1
  • 36
    • 0346689336 scopus 로고
    • 42Ar abundance
    • 42Ar abundance", Nucl. Instr. Meth., Vol. A 356, pp. 526-529, 1995.
    • (1995) Nucl. Instr. Meth. , vol.A 356 , pp. 526-529
    • Cennini, P.1
  • 38
    • 0031546921 scopus 로고    scopus 로고
    • 81Kr in the atmosphere
    • 81Kr in the atmosphere",Nucl. Instr. Meth., Vol. B 123, pp. 122-127, 1997.
    • (1997) Nucl. Instr. Meth. , vol.B 123 , pp. 122-127
    • Collon, P.1
  • 39
    • 0032301352 scopus 로고    scopus 로고
    • High resolution electromagnetic calorimetry with noble gases
    • D. Schinzel, "High resolution electromagnetic calorimetry with noble gases", Nucl. Instr. Meth. Vol., A 419, pp. 217-229, 1998.
    • (1998) Nucl. Instr. Meth. , vol.A 419 , pp. 217-229
    • Schinzel, D.1
  • 40
    • 0001196375 scopus 로고
    • Performance of the D0 Uranium-liquid argon calorimeter modules
    • P. Franzini (for the D0 Calorimeter Group), "Performance of the D0 Uranium-liquid argon calorimeter modules", Nucl. Instr. Meth., Vol. A 289, pp. 438-445, 1990.
    • (1990) Nucl. Instr. Meth. , vol.A 289 , pp. 438-445
    • Franzini, P.1
  • 41
    • 0032204281 scopus 로고    scopus 로고
    • Calibration and performance of the E706 lead and liquid argon calorimeter
    • L. Apanasevich et al. (Fermilab E706 Collaboration), "Calibration and performance of the E706 lead and liquid argon calorimeter", Nucl. Instr. Meth., Vol. A 417, pp. 50-68, 1998.
    • (1998) Nucl. Instr. Meth. , vol.A 417 , pp. 50-68
    • Apanasevich, L.1
  • 42
    • 0027872027 scopus 로고
    • The H1 liquid argon calorimeter
    • B. Andrieu et al. (H1 Calorimeter Group), "The H1 liquid argon calorimeter", Nucl. Instr. Meth., Vol. A 336, pp. 460-498, 1993.
    • (1993) Nucl. Instr. Meth. , vol.A 336 , pp. 460-498
    • Andrieu, B.1
  • 43
    • 0012151251 scopus 로고
    • Noble liquid electromagnetic calorimeters
    • D. Fournier, "Noble liquid electromagnetic calorimeters", Nucl. Instr. Meth., Vol. A 367, pp. 5-13, 1995.
    • (1995) Nucl. Instr. Meth. , vol.A 367 , pp. 5-13
    • Fournier, D.1
  • 44
    • 0032068456 scopus 로고    scopus 로고
    • The electromagnetic calorimeter of ATLAS and its performance
    • S. Jézéquel (for the ATLAS Collaboration), "The electromagnetic calorimeter of ATLAS and its performance", Nucl. Instr. Meth., Vol. A 409, pp. 589-592, 1998.
    • (1998) Nucl. Instr. Meth. , vol.A 409 , pp. 589-592
    • Jézéquel, S.1
  • 45
    • 0012114075 scopus 로고
    • The liquid krypton calorimeter for the experiment CERN-NA48
    • S. Palcstini, "The liquid krypton calorimeter for the experiment CERN-NA48",Nucl. Instr. Meth., Vol. A 367, pp. 263-266, 1995.
    • (1995) Nucl. Instr. Meth. , vol.A 367 , pp. 263-266
    • Palcstini, S.1
  • 46
    • 0034291120 scopus 로고    scopus 로고
    • Liquid noble gas calorimeters for KEDR and CMD-2M detectors
    • A. Grebenuk, "Liquid noble gas calorimeters for KEDR and CMD-2M detectors",Nucl. Instr. Meth., Vol. A 453, pp. 199-204, 2000.
    • (2000) Nucl. Instr. Meth. , vol.A 453 , pp. 199-204
    • Grebenuk, A.1
  • 47
    • 1642458481 scopus 로고    scopus 로고
    • Liquid Xe detector for mu e gamma search
    • Kashiwa, Japan, Eds. Y.Suzuki, M.Nakahata, Y.Koshio and S-Moryama, World Scientific Publishing
    • K. Ozone (for the MUEGAMMA Collaboration), "Liquid Xe detector for mu e gamma search", International Workshop on Technique and Application of Xenon Detectors," Kashiwa, Japan, 2001, Eds. Y.Suzuki, M.Nakahata, Y. Koshio and S-Moryama, World Scientific Publishing, pp. 41-49, 2002.
    • (2001) International Workshop on Technique and Application of Xenon Detectors , pp. 41-49
    • Ozone, K.1
  • 51
    • 0026867781 scopus 로고
    • The ICARUS liquid argon TPC: A complete imaging device for particle physics
    • A. Bettini et al., "The ICARUS liquid argon TPC: a complete imaging device for particle physics", Nucl. Instr. Meth., Vol. A 315, pp. 223-228, 1992.
    • (1992) Nucl. Instr. Meth. , vol.A 315 , pp. 223-228
    • Bettini, A.1
  • 52
    • 0027641276 scopus 로고
    • A three-ton liquid argon time projection chamber
    • P. Benetti et al., "A three-ton liquid argon time projection chamber",Nucl. Instr. and Meth., Vol. A 332, pp. 395-412, 1993.
    • (1993) Nucl. Instr. and Meth. , vol.A 332 , pp. 395-412
    • Benetti, P.1
  • 58
    • 0037149920 scopus 로고    scopus 로고
    • The liquid xenon set-up of the DAMA experiment
    • R. Bernabei et al., "The liquid xenon set-up of the DAMA experiment" Nucl. Instr. and Meth., Vol. A 482, pp. 728-743, 2002.
    • (2002) Nucl. Instr. and Meth. , vol.A 482 , pp. 728-743
    • Bernabei, R.1
  • 59
    • 0037050041 scopus 로고    scopus 로고
    • Measurements of scintillation efficiency and pulse shape for low energy recoils in liquid xenon
    • D. Akimov et al., "Measurements of scintillation efficiency and pulse shape for low energy recoils in liquid xenon", Nucl. Inst Meth., Vol. A 524, pp. 245-571, 2002.
    • (2002) Nucl. Inst Meth. , vol.A 524 , pp. 245-571
    • Akimov, D.1
  • 61
    • 0001650882 scopus 로고
    • Observation of electron multiplication in liquid xenon with a microstrip plate
    • A.J.P.L. Policarpo et al., "Observation of electron multiplication in liquid xenon with a microstrip plate", Nucl. Inst. Meth., Vol. A 365, pp. 568-571, 1995.
    • (1995) Nucl. Inst. Meth. , vol.A 365 , pp. 568-571
    • Policarpo, A.J.P.L.1
  • 63
    • 0012158277 scopus 로고    scopus 로고
    • Two-phase emission detectors and their applications
    • A. Bolozdynya, "Two-phase emission detectors and their applications", Nucl. Instr. Meth., Vol. A 422, pp. 314-320, 1999.
    • (1999) Nucl. Instr. Meth. , vol.A 422 , pp. 314-320
    • Bolozdynya, A.1
  • 64
    • 1642540346 scopus 로고    scopus 로고
    • Recent liquid xenon detector techniques for XMASS
    • Kashiwa, Japan
    • S. Suzuki, "Recent liquid xenon detector techniques for XMASS",LowNu Workshop, Kashiwa, Japan, 2001,
    • (2001) LowNu Workshop
    • Suzuki, S.1
  • 65
    • 0000216545 scopus 로고    scopus 로고
    • A WIMP detector with two-phase liquid xenon
    • D. Cline, "A WIMP detector with two-phase liquid xenon", Astropart. Phys., Vol. 12, pp. 373-377, 2000.
    • (2000) Astropart. Phys. , vol.12 , pp. 373-377
    • Cline, D.1
  • 66
    • 0035315271 scopus 로고    scopus 로고
    • The potential of liquid xenon for WIMP Search: The ZEPLIN diagnostic array
    • R. Luscher et al., "The potential of liquid xenon for WIMP Search: the ZEPLIN diagnostic array", Nucl. Phys. B (Proc. Suppl.), Vol. 95, pp. 233-236, 2001.
    • (2001) Nucl. Phys. B (Proc. Suppl.) , vol.95 , pp. 233-236
    • Luscher, R.1
  • 67
    • 0001128253 scopus 로고    scopus 로고
    • Xenon as a detector for dark matter search
    • H. Wang, "Xenon as a detector for dark matter search", Phys. Rep., Vol. 307, pp. 263-267, 1998.
    • (1998) Phys. Rep. , vol.307 , pp. 263-267
    • Wang, H.1
  • 68
    • 0037700570 scopus 로고    scopus 로고
    • XENON: A 1-ton liquid xenon experiment for dark matter
    • Kashiwa, Japan, Eds. Y.Suzuki, M.Nakahata, Y.Koshio and S.Moryama, World Scientific Publishing
    • E. Aprile et al., "XENON: a 1-ton liquid xenon experiment for dark matter", International Workshop on Technique and Application of Xenon Detectors, Kashiwa, Japan, 2001, Eds. Y.Suzuki, M.Nakahata, Y.Koshio and S.Moryama, World Scientific Publishing, pp. 165-178, 2002.
    • (2001) International Workshop on Technique and Application of Xenon Detectors , pp. 165-178
    • Aprile, E.1
  • 71
    • 0032623065 scopus 로고    scopus 로고
    • Current limits on the cold dark matter interaction cross section obtained by the UK collaboration
    • T. J. Sumner et al., "Current limits on the cold dark matter interaction cross section obtained by the UK collaboration", Nucl. Phys. B (Proc. Suppl.), Vol. 70, pp. 74-78, 1999.
    • (1999) Nucl. Phys. B (Proc. Suppl.) , vol.70 , pp. 74-78
    • Sumner, T.J.1
  • 72
    • 0027553468 scopus 로고
    • Detection of energy deposition down to the keV region using liquid xenon
    • P. Benetti et al., "Detection of energy deposition down to the keV region using liquid xenon", Nucl. Instr. Meth., Vol. A 327, pp. 203-206, 1993.
    • (1993) Nucl. Instr. Meth. , vol.A 327 , pp. 203-206
    • Benetti, P.1
  • 77
    • 1642499477 scopus 로고    scopus 로고
    • Gas-liquid double phase Xe detector for direct detection dark matter search by XMASS
    • Kashiwa, Japan, Eds. Y.Suzuki, M.Nakahata, Y.Koshio and S.Moryama, World Scientific Publishing
    • M. Yamashita, "Gas-liquid double phase Xe detector for direct detection dark matter search by XMASS", International Workshop on Technique and Application of Xenon Detectors, Kashiwa, Japan, 2001, Eds. Y.Suzuki, M.Nakahata, Y.Koshio and S.Moryama, World Scientific Publishing, pp. 136-143, 2002.
    • (2001) International Workshop on Technique and Application of Xenon Detectors , pp. 136-143
    • Yamashita, M.1
  • 78
    • 1642580890 scopus 로고    scopus 로고
    • Low Energy Solar Neutrino Detection by using Liquid Xenon
    • udbury, Canada; hep-ph/0008296
    • Y. Suzuki (for the Xenon Collaboration), "Low Energy Solar Neutrino Detection by using Liquid Xenon", presented at LowNu Workshop, Sudbury, Canada; hep-ph/0008296, 2000.
    • (2000) LowNu Workshop
    • Suzuki, Y.1
  • 79
    • 4243825305 scopus 로고    scopus 로고
    • Long baseline neutrino oscillations and proton decay: The ICARUS project
    • C. Rubia, "Long baseline neutrino oscillations and proton decay: the ICARUS project", Nucl. Phys. B (Proc. Suppl.), Vol. 48, pp. 172-182, 1996.
    • (1996) Nucl. Phys. B (Proc. Suppl.) , vol.48 , pp. 172-182
    • Rubia, C.1
  • 80
    • 0038529392 scopus 로고    scopus 로고
    • LAANND, a massive liquid argon detector for proton decay, supernova and solar neutrino studies, and a neutrino factory detector
    • D.B. Cline, F. Sergiampietri, J.G. Learned, and K.T. McDonald, "LAANND, a massive liquid argon detector for proton decay, supernova and solar neutrino studies, and a neutrino factory detector", Nucl. lustrum. Meth., Vol. A503, pp. 136-140, 2003.
    • (2003) Nucl. Instrum. Meth. , vol.A503 , pp. 136-140
    • Cline, D.B.1    Sergiampietri, F.2    Learned, J.G.3    McDonald, K.T.4
  • 81
    • 0000668146 scopus 로고    scopus 로고
    • Review on double beta decay experiments and comparison with theory
    • A. Morales, "Review on double beta decay experiments and comparison with theory", Nucl. Phys. B (Proc. Suppl.), Vol. 77, pp. 335-345, 1999.
    • (1999) Nucl. Phys. B (Proc. Suppl.) , vol.77 , pp. 335-345
    • Morales, A.1
  • 83
    • 0000858997 scopus 로고
    • PET detector modules based on novel detector technologies
    • W.W. Moses, S.E. Derenzo and T.F. Budinger, "PET detector modules based on novel detector technologies", Nucl. Instr. Meth., Vol. A 353, pp. 189-194, 1994.
    • (1994) Nucl. Instr. Meth. , vol.A 353 , pp. 189-194
    • Moses, W.W.1    Derenzo, S.E.2    Budinger, T.F.3
  • 85
    • 1642499475 scopus 로고
    • Liquid xenon multiwire proportional chamber for nuclear medicine application
    • Tokyo
    • H. Zaklad et al., "Liquid xenon multiwire proportional chamber for nuclear medicine application", Proc. of the First World Congress on Nuclear Medicine, Tokyo, pp. 362-367, 1974.
    • (1974) Proc. of the First World Congress on Nuclear Medicine , pp. 362-367
    • Zaklad, H.1
  • 87
    • 0012115202 scopus 로고    scopus 로고
    • Liquid xenon detectors for medical imaging
    • V. Chepel, "Liquid xenon detectors for medical imaging", Physica Medica XII, pp. 15-18, 1996.
    • (1996) Physica Medica XII , pp. 15-18
    • Chepel, V.1
  • 90
    • 0027147636 scopus 로고
    • New liquid xenon scintillation detector for positron emission tomography
    • V. Chepel, "New liquid xenon scintillation detector for positron emission tomography", Nucl. Tracks. Rad. Meas., Vol. 21, pp. 47-51, 1993.
    • (1993) Nucl. Tracks. Rad. Meas. , vol.21 , pp. 47-51
    • Chepel, V.1
  • 93
    • 1642499469 scopus 로고    scopus 로고
    • A liquid xenon PET camera for neuro-science
    • J. Collot, S. Jan, and E. Tournefier, "A liquid xenon PET camera for neuro-science", Frascatti Physics Series, Vol. 21, pp. 305-313, 2000.
    • (2000) Frascatti Physics Series , vol.21 , pp. 305-313
    • Collot, J.1    Jan, S.2    Tournefier, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.