메뉴 건너뛰기




Volumn 29, Issue 1, 2004, Pages 9-15

Comparative Depths of Cure among Various Curing Light Types and Methods

Author keywords

[No Author keywords available]

Indexed keywords

HALOGEN; RESIN; SILICON DIOXIDE; TUNGSTEN; Z 100 COMPOSITE RESIN; Z-100 COMPOSITE RESIN;

EID: 1642479187     PISSN: 03617734     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (25)

References (31)
  • 1
    • 84985801100 scopus 로고
    • Factors affecting the quantity of remaining double bonds in restorative resin polymers
    • Asmussen E (1982) Factors affecting the quantity of remaining double bonds in restorative resin polymers Scandinavian Journal of Dental Research 90(6) 490-496.
    • (1982) Scandinavian Journal of Dental Research , vol.90 , Issue.6 , pp. 490-496
    • Asmussen, E.1
  • 2
    • 0023969675 scopus 로고
    • Effect of exposure time on the depth of polymerization of a visible light-cured composite resin
    • Baharav H, Abraham D, Cardash HS & Helft M (1988) Effect of exposure time on the depth of polymerization of a visible light-cured composite resin Journal of Oral Rehabilitation 15(2) 167-172.
    • (1988) Journal of Oral Rehabilitation , vol.15 , Issue.2 , pp. 167-172
    • Baharav, H.1    Abraham, D.2    Cardash, H.S.3    Helft, M.4
  • 4
    • 0018925880 scopus 로고
    • Factors affecting the depth of cure of UV-polymerized composites
    • Cook WD (1980) Factors affecting the depth of cure of UV-polymerized composites Journal of Dental Research 59(5) 800-808.
    • (1980) Journal of Dental Research , vol.59 , Issue.5 , pp. 800-808
    • Cook, W.D.1
  • 5
    • 0023297191 scopus 로고
    • A comparison of four modes of evaluating depth of cure of light-activated composites
    • DeWald JP & Ferracane JL (1987) A comparison of four modes of evaluating depth of cure of light-activated composites Journal of Dental Research 66(3) 727-730.
    • (1987) Journal of Dental Research , vol.66 , Issue.3 , pp. 727-730
    • DeWald, J.P.1    Ferracane, J.L.2
  • 6
    • 0022702252 scopus 로고
    • Relationship between shade and depth of cure for light-activated dental composite resins
    • Ferracane JL, Aday P, Matsumoto H & Marker VA (1986) Relationship between shade and depth of cure for light-activated dental composite resins Dental Materials 2(2) 80-84.
    • (1986) Dental Materials , vol.2 , Issue.2 , pp. 80-84
    • Ferracane, J.L.1    Aday, P.2    Matsumoto, H.3    Marker, V.A.4
  • 9
    • 84989592221 scopus 로고
    • Correlation between depth of cure and surface hardness of a light-activated resin
    • Hansen EK & Asmussen E (1993) Correlation between depth of cure and surface hardness of a light-activated resin Scandinavian Journal of Dental Research 101(1) 62-64.
    • (1993) Scandinavian Journal of Dental Research , vol.101 , Issue.1 , pp. 62-64
    • Hansen, E.K.1    Asmussen, E.2
  • 10
    • 0027682676 scopus 로고
    • Depth of cure of radiation-activated materials-effect of mould material and cavity size
    • Harrington E & Wilson HJ (1993) Depth of cure of radiation-activated materials-effect of mould material and cavity size Journal of Dentistry 21(5) 305-311.
    • (1993) Journal of Dentistry , vol.21 , Issue.5 , pp. 305-311
    • Harrington, E.1    Wilson, H.J.2
  • 11
    • 0010455466 scopus 로고
    • ISO International Standard 4049 International Standards Organization
    • ISO International Standard 4049 (1988) Polymer-based filling restorative and luting materials International Standards Organization.
    • (1988) Polymer-based Filling Restorative and Luting Materials
  • 12
    • 1642501402 scopus 로고    scopus 로고
    • ISO International Standard 4049 International Standards Organization
    • ISO International Standard 4049 (2000) Resin-based Filling Materials. International Standards Organization.
    • (2000) Resin-based Filling Materials
  • 13
    • 0027735843 scopus 로고
    • Radiometric and spectroradiometric comparison of power outputs of five visible light-curing units
    • Lee SY, Chiu CH, Boghosian A & Greener EH (1993) Radiometric and spectroradiometric comparison of power outputs of five visible light-curing units Journal of Dentistry 21(6) 373-377.
    • (1993) Journal of Dentistry , vol.21 , Issue.6 , pp. 373-377
    • Lee, S.Y.1    Chiu, C.H.2    Boghosian, A.3    Greener, E.H.4
  • 14
    • 0024758197 scopus 로고
    • Output from visible-light activation units and depth of cure of light- Activated composites
    • McCabe JF & Carrick TE (1989) Output from visible-light activation units and depth of cure of light-activated composites Journal of Dental Research 68(11) 1534-1539.
    • (1989) Journal of Dental Research , vol.68 , Issue.11 , pp. 1534-1539
    • McCabe, J.F.1    Carrick, T.E.2
  • 15
    • 0033599665 scopus 로고    scopus 로고
    • Dental composite depth of cure with halogen and blue light emitting diode technology
    • Mills RW, Jandt KD & Ashworth SH (1999) Dental composite depth of cure with halogen and blue light emitting diode technology British Dental Journal 186(8) 388-391.
    • (1999) British Dental Journal , vol.186 , Issue.8 , pp. 388-391
    • Mills, R.W.1    Jandt, K.D.2    Ashworth, S.H.3
  • 16
    • 11244308938 scopus 로고    scopus 로고
    • Optical power outputs, spectra and dental composite depths of cure, obtained with blue light emitting diode (LED) and halogen light curing units (LCUs)
    • Mills RW, Uhl A & Jandt KD (2002) Optical power outputs, spectra and dental composite depths of cure, obtained with blue light emitting diode (LED) and halogen light curing units (LCUs) British Dental Journal 192(8) 459-463.
    • (2002) British Dental Journal , vol.192 , Issue.8 , pp. 459-463
    • Mills, R.W.1    Uhl, A.2    Jandt, K.D.3
  • 17
    • 0036013938 scopus 로고    scopus 로고
    • High power light emitting diode (LED) arrays versus halogen light polymerization of oral biomaterials: Barcol hardness, compressive strength and radiometric properties
    • Mills RW, Uhl A, Blackwell GB & Jandt KD (2002) High power light emitting diode (LED) arrays versus halogen light polymerization of oral biomaterials: Barcol hardness, compressive strength and radiometric properties Biomaterials 23(4) 2955-2963.
    • (2002) Biomaterials , vol.23 , Issue.4 , pp. 2955-2963
    • Mills, R.W.1    Uhl, A.2    Blackwell, G.B.3    Jandt, K.D.4
  • 18
    • 0019598866 scopus 로고
    • Ultraviolet light and ultraviolet light-activated composite resins
    • Murray GA, Yates JL & Newman SM (1981) Ultraviolet light and ultraviolet light-activated composite resins Journal of Prosthetic Dentistry 46(2) 167-170.
    • (1981) Journal of Prosthetic Dentistry , vol.46 , Issue.2 , pp. 167-170
    • Murray, G.A.1    Yates, J.L.2    Newman, S.M.3
  • 20
    • 0024023292 scopus 로고
    • Correlation of parameters used to estimate monomer conversion in a light-cured composite
    • Rueggeberg FA & Craig RG (1988) Correlation of parameters used to estimate monomer conversion in a light-cured composite Journal of Dental Research 67(6) 932-937.
    • (1988) Journal of Dental Research , vol.67 , Issue.6 , pp. 932-937
    • Rueggeberg, F.A.1    Craig, R.G.2
  • 21
    • 0028317218 scopus 로고
    • Effect of light intensity and exposure duration on cure of resin composite
    • Rueggeberg FA, Caughman WF & Curtis JW Jr (1994) Effect of light intensity and exposure duration on cure of resin composite Operative Dentistry 19(1) 26-32.
    • (1994) Operative Dentistry , vol.19 , Issue.1 , pp. 26-32
    • Rueggeberg, F.A.1    Caughman, W.F.2    Curtis Jr., J.W.3
  • 23
    • 0020020499 scopus 로고
    • Conversion in different depths of ultraviolet and visible light activated composite materials
    • Ruyter IE & Øysæd H (1982) Conversion in different depths of ultraviolet and visible light activated composite materials Acta Odontologica Scandinavica 40(3) 179-192.
    • (1982) Acta Odontologica Scandinavica , vol.40 , Issue.3 , pp. 179-192
    • Ruyter, I.E.1    Øysæd, H.2
  • 25
    • 0033158981 scopus 로고    scopus 로고
    • Curing depth of prosthetic composite materials polymerized with their proprietary photo-curing units
    • Tanoue N, Matsumura H & Atsuta M (1999) Curing depth of prosthetic composite materials polymerized with their proprietary photo-curing units Journal of Oral Rehabilitation 26(7) 594-599.
    • (1999) Journal of Oral Rehabilitation , vol.26 , Issue.7 , pp. 594-599
    • Tanoue, N.1    Matsumura, H.2    Atsuta, M.3
  • 26
    • 0033090276 scopus 로고    scopus 로고
    • Successful photocuring: Don't restore without it
    • Tate WH, Porter KH & Dosch RO (1999) Successful photocuring: Don't restore without it Operative Dentistry 24(2) 109-114.
    • (1999) Operative Dentistry , vol.24 , Issue.2 , pp. 109-114
    • Tate, W.H.1    Porter, K.H.2    Dosch, R.O.3
  • 27
    • 84989591443 scopus 로고
    • Marginal adaptation of a restorative resin polymerized at reduced rate
    • Uno S & Asmussen E (1991) Marginal adaptation of a restorative resin polymerized at reduced rate Scandinavian Journal of Dental Research 99(5) 440-444.
    • (1991) Scandinavian Journal of Dental Research , vol.99 , Issue.5 , pp. 440-444
    • Uno, S.1    Asmussen, E.2
  • 28
    • 0029319428 scopus 로고
    • Influence of light intensity on two restorative systems
    • Unterbrink GL & Muessner R (1995) Influence of light intensity on two restorative systems Journal of Dentistry 23(3) 183-189.
    • (1995) Journal of Dentistry , vol.23 , Issue.3 , pp. 183-189
    • Unterbrink, G.L.1    Muessner, R.2
  • 29
    • 0141893303 scopus 로고    scopus 로고
    • Thermal emission by different light-curing units
    • Yap AU & Soh MS (2003) Thermal emission by different light-curing units Operative Dentistry 28(3) 260-266.
    • (2003) Operative Dentistry , vol.28 , Issue.3 , pp. 260-266
    • Yap, A.U.1    Soh, M.S.2
  • 30
    • 0141782380 scopus 로고    scopus 로고
    • Composite cure and shrinkage associated with high intensity curing light
    • Yap AU, Wong NY & Siow KS (2003) Composite cure and shrinkage associated with high intensity curing light Operative Dentistry 28(4) 357-364.
    • (2003) Operative Dentistry , vol.28 , Issue.4 , pp. 357-364
    • Yap, A.U.1    Wong, N.Y.2    Siow, K.S.3
  • 31
    • 0022119136 scopus 로고
    • Factors affecting cure of visible light activated composites
    • Yearn JA (1985) Factors affecting cure of visible light activated composites International Dental Journal 35(3) 218-225.
    • (1985) International Dental Journal , vol.35 , Issue.3 , pp. 218-225
    • Yearn, J.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.