메뉴 건너뛰기




Volumn 28, Issue 1, 2004, Pages 59-62

An Accurate Method for the Determination of Carboxyhemoglobin in Postmortem Blood Using GC-TCD

Author keywords

[No Author keywords available]

Indexed keywords

CARBON MONOXIDE; CARBOXYHEMOGLOBIN; METHEMOGLOBIN; REDUCING AGENT; SODIUM DITHIONITE;

EID: 1642458203     PISSN: 01464760     EISSN: None     Source Type: Journal    
DOI: 10.1093/jat/28.1.59     Document Type: Article
Times cited : (23)

References (24)
  • 1
    • 85039588404 scopus 로고    scopus 로고
    • Aviation Safety Research Act of 1988, Public Law 100-591 [H.R.4686], Civil Aeromedical Research, One Hundredth Congress of the United States, 2nd Session, 1988
    • Aviation Safety Research Act of 1988, Public Law 100-591 [H.R.4686], Civil Aeromedical Research, One Hundredth Congress of the United States, 2nd Session, 1988.
  • 2
    • 0035479174 scopus 로고    scopus 로고
    • Blood carbon monoxide and hydrogen cyanide concentrations in the fatalities of fire and non-fire associated civil aviation accidents, 1991-1998
    • A.K. Chaturvedi, D.R. Smith, and C.V. Canfield. Blood carbon monoxide and hydrogen cyanide concentrations in the fatalities of fire and non-fire associated civil aviation accidents, 1991-1998. Forensic Sci. Int. 121: 183-188 (2001).
    • (2001) Forensic Sci. Int. , vol.121 , pp. 183-188
    • Chaturvedi, A.K.1    Smith, D.R.2    Canfield, C.V.3
  • 3
    • 0027716009 scopus 로고
    • Crashes of commuter aircraft and air taxis: What determines pilot survival?
    • G. Li and S.P. Baker. Crashes of commuter aircraft and air taxis: what determines pilot survival? J. Occup. Med. 35: 1244-1249 (1993).
    • (1993) J. Occup. Med. , vol.35 , pp. 1244-1249
    • Li, G.1    Baker, S.P.2
  • 4
    • 1642558949 scopus 로고    scopus 로고
    • Carbon monoxide levels in cabins need to be measured for potential hazard, expert urges
    • V. Netten. Carbon monoxide levels in cabins need to be measured for potential hazard, expert urges. Air Safety Week 13: 1-2 (1999).
    • (1999) Air Safety Week , vol.13 , pp. 1-2
    • Netten, V.1
  • 6
    • 0033000232 scopus 로고    scopus 로고
    • Preparation of carboxyhemoglobin standard and calculation of spectrophotometric quantitation constants
    • D.V. Canfield, M.D. Smith, R.M. Ritter, and A.K. Chaturvedi. Preparation of carboxyhemoglobin standard and calculation of spectrophotometric quantitation constants. J. Forensic Sci. 44: 409-412 (1999).
    • (1999) J. Forensic Sci. , vol.44 , pp. 409-412
    • Canfield, D.V.1    Smith, M.D.2    Ritter, R.M.3    Chaturvedi, A.K.4
  • 7
    • 0022635811 scopus 로고
    • Determination of carbon monoxide in blood by gas chromatography using a thermal conductivity detector
    • L.R. Goldbaum, D.H. Chace, and N.T. Lappas. Determination of carbon monoxide in blood by gas chromatography using a thermal conductivity detector. J. Forensic Sci. 31: 133-141 (1986).
    • (1986) J. Forensic Sci. , vol.31 , pp. 133-141
    • Goldbaum, L.R.1    Chace, D.H.2    Lappas, N.T.3
  • 8
    • 0027393806 scopus 로고
    • Estimation of perimortal percent carboxy-heme in non-standard postmortem specimens using analysis of carbon monoxide by GC/MS and iron by flame absorption spectroscopy
    • R.A. Middleberg, D.E. Easterling, S.F. Zelonis, F. Rieders, and M.F. Rieders. Estimation of perimortal percent carboxy-heme in non-standard postmortem specimens using analysis of carbon monoxide by GC/MS and iron by flame absorption spectroscopy. J. Anal. Toxicol. 17: 11-13 (1993).
    • (1993) J. Anal. Toxicol. , vol.17 , pp. 11-13
    • Middleberg, R.A.1    Easterling, D.E.2    Zelonis, S.F.3    Rieders, F.4    Rieders, M.F.5
  • 9
    • 0019483585 scopus 로고
    • A comparative study of analytical methods to determine postmortem changes in carbon monoxide concentration
    • C.L. Winek and D.M. Prex. A comparative study of analytical methods to determine postmortem changes in carbon monoxide concentration. Forensic Sci. Int. 18: 181-187 (1981).
    • (1981) Forensic Sci. Int. , vol.18 , pp. 181-187
    • Winek, C.L.1    Prex, D.M.2
  • 10
    • 0016365133 scopus 로고
    • Rapid, accurate technique for determination of carbon monoxide in blood
    • T.E. Dahms and S.M. Horvath. Rapid, accurate technique for determination of carbon monoxide in blood. Clin. Chem. 20: 533-537 (1974).
    • (1974) Clin. Chem. , vol.20 , pp. 533-537
    • Dahms, T.E.1    Horvath, S.M.2
  • 11
    • 0021929334 scopus 로고
    • The effects of storage conditions on the stability of carbon monoxide in postmortem blood
    • A. Ocak, J.C. Valentour, and R.V. Blanke. The effects of storage conditions on the stability of carbon monoxide in postmortem blood. J. Anal. Toxicol. 9: 202-206 (1985).
    • (1985) J. Anal. Toxicol. , vol.9 , pp. 202-206
    • Ocak, A.1    Valentour, J.C.2    Blanke, R.V.3
  • 12
    • 0342572527 scopus 로고    scopus 로고
    • Automated determination of carboxyhemoglobin contents in autopsy materials using head-space gas chromatography/mass spectrometry
    • S. Oritani, B. Zhu, K. Ishida, K. Shimotouge, L. Quan, M.Q. Fujita, and H. Maeda. Automated determination of carboxyhemoglobin contents in autopsy materials using head-space gas chromatography/mass spectrometry. Forensic Sci. Int. 113: 375-379 (2000).
    • (2000) Forensic Sci. Int. , vol.113 , pp. 375-379
    • Oritani, S.1    Zhu, B.2    Ishida, K.3    Shimotouge, K.4    Quan, L.5    Fujita, M.Q.6    Maeda, H.7
  • 13
    • 0028673607 scopus 로고
    • Micro analysis of carbon monoxide in blood by head-space capillary gas chromatography
    • J. Van Dam and P. Daenens. Microanalysis of carbon monoxide in blood by head-space capillary gas chromatography. J. Forensic Sci. 39: 473-478 (1994).
    • (1994) J. Forensic Sci. , vol.39 , pp. 473-478
    • Van Dam, J.1    Daenens, P.2
  • 14
    • 0032611223 scopus 로고    scopus 로고
    • Formation of methemoglobin and free radicals in erythrocytes
    • H. Nohl and K. Stolze. Formation of methemoglobin and free radicals in erythrocytes. Met. Ions Biol. Syst. 36: 289-307 (1999).
    • (1999) Met. Ions Biol. Syst. , vol.36 , pp. 289-307
    • Nohl, H.1    Stolze, K.2
  • 15
    • 0024495744 scopus 로고
    • Study on the effects of heat on blood and on the postmortem estimation of carboxyhemoglobin and methemoglobin
    • G.P. Fechner and D.J. Gee. Study on the effects of heat on blood and on the postmortem estimation of carboxyhemoglobin and methemoglobin. Forensic Sci. Int. 40: 63-67 (1989).
    • (1989) Forensic Sci. Int. , vol.40 , pp. 63-67
    • Fechner, G.P.1    Gee, D.J.2
  • 16
    • 0025252995 scopus 로고
    • Storage of blood for methemoglobin determination: Comparison of storage with a cryoprotectant at -30°C and without any additions at -80°C of -196°C
    • K. Sato, K. Tamaki, H. Tsutsumi, H. Okajima, and Y. Katsumata. Storage of blood for methemoglobin determination: comparison of storage with a cryoprotectant at -30°C and without any additions at -80°C of -196°C. Forensic Sci. Int. 45: 129-134 (1990).
    • (1990) Forensic Sci. Int. , vol.45 , pp. 129-134
    • Sato, K.1    Tamaki, K.2    Tsutsumi, H.3    Okajima, H.4    Katsumata, Y.5
  • 17
    • 0036231763 scopus 로고    scopus 로고
    • Postcollection rise in methemoglobin level in frozen blood specimens
    • K.L. Wallace and S.C. Curry. Postcollection rise in methemoglobin level in frozen blood specimens. Clin. Toxicol. 40: 91-94 (2002).
    • (2002) Clin. Toxicol. , vol.40 , pp. 91-94
    • Wallace, K.L.1    Curry, S.C.2
  • 18
    • 0032710821 scopus 로고    scopus 로고
    • Methemoglobinemia: Etiology, pharmocology, and clinical management
    • R.O. Wright, W.J. Lewander, and A.D. Woolf. Methemoglobinemia: etiology, pharmocology, and clinical management. Ann. Emer. Med. 34: 646-656 (1999).
    • (1999) Ann. Emer. Med. , vol.34 , pp. 646-656
    • Wright, R.O.1    Lewander, W.J.2    Woolf, A.D.3
  • 19
    • 0000960057 scopus 로고
    • The effects of postmortem changes on carboxyhemoglobin results
    • A.M. Dominguez, J.R. Halstead, and T.J. Domanski. The effects of postmortem changes on carboxyhemoglobin results. J. Forensic Sci. 9:330-341 (1964).
    • (1964) J. Forensic Sci. , vol.9 , pp. 330-341
    • Dominguez, A.M.1    Halstead, J.R.2    Domanski, T.J.3
  • 20
    • 0015539634 scopus 로고
    • Measurement of carboxyhemoglobin and carbon monoxide in blood
    • K.M. Dubowski and J.L. Luke. Measurement of carboxyhemoglobin and carbon monoxide in blood. Ann. Clin. Lab. Sci. 3: 53-65 (1973).
    • (1973) Ann. Clin. Lab. Sci. , vol.3 , pp. 53-65
    • Dubowski, K.M.1    Luke, J.L.2
  • 21
    • 1642518008 scopus 로고
    • The determination of carbon monoxide in blood
    • T.A. Douglas. The determination of carbon monoxide in blood. Ann. Occup. Hyg. 5: 211-216 (1962).
    • (1962) Ann. Occup. Hyg. , vol.5 , pp. 211-216
    • Douglas, T.A.1
  • 22
    • 0016032020 scopus 로고
    • New method for rapid determination of carboxyhemoglobin by use of double-wavelength spectrophotometry
    • A. Ramieri, P. Jatlow, and D. Seligson. New method for rapid determination of carboxyhemoglobin by use of double-wavelength spectrophotometry. Clin. Chem. 20: 278-281 (1974).
    • (1974) Clin. Chem. , vol.20 , pp. 278-281
    • Ramieri, A.1    Jatlow, P.2    Seligson, D.3
  • 23
    • 0033809845 scopus 로고    scopus 로고
    • Carbon monoxide stability in stored postmortem blood samples
    • G.W. Kunsman, C.L. Presses, and P. Rodriquez. Carbon monoxide stability in stored postmortem blood samples. J. Anal. Toxicol. 24: 572-578 (2000).
    • (2000) J. Anal. Toxicol. , vol.24 , pp. 572-578
    • Kunsman, G.W.1    Presses, C.L.2    Rodriquez, P.3
  • 24
    • 0033009505 scopus 로고    scopus 로고
    • Accuracy of methemoglobin measurements: Comparison of six different commercial devices and one manual method
    • J. Dotsch, S. Demirakca, D. Hahn, N. Katz, P. Gonne, and W. Rascher. Accuracy of methemoglobin measurements: Comparison of six different commercial devices and one manual method. Crit. Care Med. 27: 1191-1194 (1999).
    • (1999) Crit. Care Med. , vol.27 , pp. 1191-1194
    • Dotsch, J.1    Demirakca, S.2    Hahn, D.3    Katz, N.4    Gonne, P.5    Rascher, W.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.