메뉴 건너뛰기




Volumn 36, Issue , 2004, Pages 149-172

Flow-rate measurement in two-phase flow

Author keywords

Coriolis; Electromagnetic; Flow meter; Gamma ray; Venturi

Indexed keywords

DENSITOMETERS; FIBER OPTIC SENSORS; FLOW MEASUREMENT; GAMMA RAYS; MANOMETERS; PRESSURE DROP;

EID: 1642292598     PISSN: 00664189     EISSN: None     Source Type: Book Series    
DOI: 10.1146/annurev.fluid.36.050802.121935     Document Type: Article
Times cited : (65)

References (49)
  • 4
    • 0000785266 scopus 로고
    • Simultaneous flow of oil and gas
    • Baker O. 1954. Simultaneous flow of oil and gas. Oil Gas J. 53:185
    • (1954) Oil Gas J. , vol.53 , pp. 185
    • Baker, O.1
  • 5
    • 0028519639 scopus 로고
    • Coriolis flowmeters: Industrial practice and published information
    • Baker RC. 1994. Coriolis flowmeters: industrial practice and published information. Flow Meas. Instrum. 5(4):229-46
    • (1994) Flow Meas. Instrum. , vol.5 , Issue.4 , pp. 229-246
    • Baker, R.C.1
  • 9
    • 84958436696 scopus 로고
    • Theory of induced voltage electromagnetic flow measurement
    • Bevir MK. 1970. Theory of induced voltage electromagnetic flow measurement. J. Fluid Mech. 43:577
    • (1970) J. Fluid Mech. , vol.43 , pp. 577
    • Bevir, M.K.1
  • 10
    • 0035742045 scopus 로고    scopus 로고
    • Flow measurement with an electromagnetic flowmeter in two-phase bubbly and slug flow regimes
    • Cha J-E, Ahn YC, Kim M-H. 2001. Flow measurement with an electromagnetic flowmeter in two-phase bubbly and slug flow regimes. Flow Meas. Instrum. 12(5-6):329-40
    • (2001) Flow Meas. Instrum. , vol.12 , Issue.5-6 , pp. 329-340
    • Cha, J.-E.1    Ahn, Y.C.2    Kim, M.-H.3
  • 11
    • 84987401170 scopus 로고
    • Horizontal pipeline flow of equal density oil-water mixtures
    • Charles ME, Govier CW, Hodgson GW. 1961. Horizontal pipeline flow of equal density oil-water mixtures. Can. J. Chem. Eng. 39(1):27-36
    • (1961) Can. J. Chem. Eng. , vol.39 , Issue.1 , pp. 27-36
    • Charles, M.E.1    Govier, C.W.2    Hodgson, G.W.3
  • 12
    • 0033998746 scopus 로고    scopus 로고
    • The identification of external factors which influence the calibration of Coriolis massflow meter
    • Cheesewright R, Clark C, Bisset D. 2000. The identification of external factors which influence the calibration of Coriolis massflow meter. Flow Meas. Instrum, 11(1):1-10
    • (2000) Flow Meas. Instrum, , vol.11 , Issue.1 , pp. 1-10
    • Cheesewright, R.1    Clark, C.2    Bisset, D.3
  • 16
    • 0028519633 scopus 로고
    • High-precision coriolis mass flowmeter for bulk material two-phase flow
    • Dimaczek G, Fassbinder H-G, Emmel A, Kupfer R. 1994. High-precision coriolis mass flowmeter for bulk material two-phase flow. Flow Meas. Instrum. 5(4):295-302
    • (1994) Flow Meas. Instrum. , vol.5 , Issue.4 , pp. 295-302
    • Dimaczek, G.1    Fassbinder, H.-G.2    Emmel, A.3    Kupfer, R.4
  • 20
    • 0036509479 scopus 로고    scopus 로고
    • Performance of a Venturi meter in gas-liquid flow in the presence of dissolved gases
    • Elperin T, Fominykh A, Klochko M. 2002. Performance of a Venturi meter in gas-liquid flow in the presence of dissolved gases. Flow Meas. Instrum. 13(1):13-16
    • (2002) Flow Meas. Instrum. , vol.13 , Issue.1 , pp. 13-16
    • Elperin, T.1    Fominykh, A.2    Klochko, M.3
  • 21
  • 27
    • 0021663537 scopus 로고
    • Performance of a Coriolis type mass flowmeter in the measurement of two-phase air-liquid mixtures. Mass flow measurements
    • Grumski JT, Bajura RA. 1984. Performance of a Coriolis type mass flowmeter in the measurement of two-phase air-liquid mixtures. Mass flow measurements. ASME Winter Annu. Meet., New Orleans
    • (1984) ASME Winter Annu. Meet., New Orleans
    • Grumski, J.T.1    Bajura, R.A.2
  • 30
    • 1642348658 scopus 로고    scopus 로고
    • Performance evaluation of eight electromagnetic flowmeters with fine sand slurries
    • Heywood NI, Mehta KB. 1999. Performance evaluation of eight electromagnetic flowmeters with fine sand slurries. Hydrotransport 14. BHRG, pp. 413-31
    • (1999) Hydrotransport 14. BHRG , pp. 413-431
    • Heywood, N.I.1    Mehta, K.B.2
  • 35
    • 85137169869 scopus 로고
    • A fast response truemass-rate flowmeter
    • Li YT, Lee SY. 1953. A fast response truemass-rate flowmeter. Trans. ASME 175:835-41
    • (1953) Trans. ASME , vol.175 , pp. 835-841
    • Li, Y.T.1    Lee, S.Y.2
  • 37
    • 0025503081 scopus 로고
    • Development of an electromagnetic flowmeter for studying gas liquid two phase flow
    • Murakami M, Maruo K, Yoshiki T. 1990. Development of an electromagnetic flowmeter for studying gas liquid two phase flow. Int. Chem. Eng. 30(4):699-702
    • (1990) Int. Chem. Eng. , vol.30 , Issue.4 , pp. 699-702
    • Murakami, M.1    Maruo, K.2    Yoshiki, T.3
  • 41
    • 1642280393 scopus 로고    scopus 로고
    • The late stages of approach of liquid-liquid interfaces to smooth probes; rupture by asperities
    • ed. AC King, YD Shikhmurzaev Dordrecht: Kluwer
    • Pearson JRA. 2001. The late stages of approach of liquid-liquid interfaces to smooth probes; rupture by asperities. IUTAM Symp. Free Surface Flows, Birmingham, UK, ed. AC King, YD Shikhmurzaev, p. 237. Dordrecht: Kluwer
    • (2001) IUTAM Symp. Free Surface Flows, Birmingham, UK , pp. 237
    • Pearson, J.R.A.1
  • 42
    • 0035396165 scopus 로고    scopus 로고
    • A local optical probe using fluorescence and reflectance for measurement of volume fraction in multi-phase flows
    • Ramos RT, Holmes A, Wu X, Dussan E. 2001. A local optical probe using fluorescence and reflectance for measurement of volume fraction in multi-phase flows. Meas. Sci. Technol. 12:871-76
    • (2001) Meas. Sci. Technol. , vol.12 , pp. 871-876
    • Ramos, R.T.1    Holmes, A.2    Wu, X.3    Dussan, E.4
  • 43
    • 0029768194 scopus 로고    scopus 로고
    • Measurement of the oil and water flow rates in a horizontal well using chemical markers and a Pulsed-Neutron Tool
    • 6-9 Oct
    • Roscoe BA, Lenn C, Jones TGJ, Whittaker C. 1996. Measurement of the oil and water flow rates in a horizontal well using chemical markers and a Pulsed-Neutron Tool. SPE Pap. 36563, 6-9 Oct.
    • (1996) SPE Pap. 36563
    • Roscoe, B.A.1    Lenn, C.2    Jones, T.G.J.3    Whittaker, C.4
  • 45
    • 0018924238 scopus 로고
    • Regime maps for air water two phase flow
    • Spedding PL, Nguyen PT. 1980. Regime maps for air water two phase flow. Chem. Eng. Sci. 35:779-93
    • (1980) Chem. Eng. Sci. , vol.35 , pp. 779-793
    • Spedding, P.L.1    Nguyen, P.T.2
  • 46
    • 0035742047 scopus 로고    scopus 로고
    • Wet gas metering with a horizontally mounted Venturi meter
    • Steven RN. 2001. Wet gas metering with a horizontally mounted Venturi meter. Flow Meas. Instrum. 12(5-6):361-72
    • (2001) Flow Meas. Instrum. , vol.12 , Issue.5-6 , pp. 361-372
    • Steven, R.N.1
  • 48
    • 0022812743 scopus 로고
    • Electromagnetic flowmeter sensitivity with twophase flow
    • Wyatt DG. 1986. Electromagnetic flowmeter sensitivity with twophase flow. Int. J. Multiph. Flow 12(6):1009-17
    • (1986) Int. J. Multiph. Flow , vol.12 , Issue.6 , pp. 1009-1017
    • Wyatt, D.G.1
  • 49
    • 0025537424 scopus 로고
    • Coriolis flowmeters for accurate measurement of liquid properties
    • Young A. 1990. Coriolis flowmeters for accurate measurement of liquid properties. Adv. Instrum., ISA Proc., 45(4):1891-98
    • (1990) Adv. Instrum., ISA Proc. , vol.45 , Issue.4 , pp. 1891-1898
    • Young, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.