메뉴 건너뛰기




Volumn 4, Issue 1, 2004, Pages 13-19

Stent restenosis and the use of drug-eluting stents in patients with diabetes mellitus

Author keywords

[No Author keywords available]

Indexed keywords

ABCIXIMAB; CLOPIDOGREL; FIBRINOGEN RECEPTOR ANTAGONIST; PACLITAXEL; RAPAMYCIN; TICLOPIDINE; TIROFIBAN; BIOMATERIAL;

EID: 1642279454     PISSN: 15344827     EISSN: None     Source Type: Journal    
DOI: 10.1007/s11892-004-0005-9     Document Type: Review
Times cited : (6)

References (65)
  • 1
    • 76549154241 scopus 로고
    • Transluminal treatment of arteriosclerotic obstructions
    • Dotter CT, Judkins MR: Transluminal treatment of arteriosclerotic obstructions. Circulation 1964, 30: 654-670.
    • (1964) Circulation , vol.30 , pp. 654-670
    • Dotter, C.T.1    Judkins, M.R.2
  • 2
    • 0031005933 scopus 로고    scopus 로고
    • Catheter-based radiotherapy to inhibit restenosis after coronary stenting
    • Teirstein PS, Massullo V, Jani S, et al.: Catheter-based radiotherapy to inhibit restenosis after coronary stenting. N Engl J Med 1997, 336: 1697-1703.
    • (1997) N. Engl. J. Med. , vol.336 , pp. 1697-1703
    • Teirstein, P.S.1    Massullo, V.2    Jani, S.3
  • 3
    • 0027195816 scopus 로고
    • Multicenter investigation of coronary stenting to treat acute or treated closure after percutaneous transluminal coronary angioplasty: Clinical and angiographic outcomes
    • George B, Voorhees W, Roubin G, et al.: Multicenter investigation of coronary stenting to treat acute or treated closure after percutaneous transluminal coronary angioplasty: clinical and angiographic outcomes. J Am Coll Cardiol 1993, 22: 135-143.
    • (1993) J. Am. Coll. Cardiol. , vol.22 , pp. 135-143
    • George, B.1    Voorhees, W.2    Roubin, G.3
  • 4
    • 0028061452 scopus 로고
    • Long-term angiographic and clinical outcome after implantation of a balloon-expandable stent in the native coronary circulation
    • Savage M, Fischmann D, Schatz R, et al.: Long-term angiographic and clinical outcome after implantation of a balloon-expandable stent in the native coronary circulation. J Am Coll Cardiol 1994, 24: 1207-1212.
    • (1994) J. Am. Coll. Cardiol. , vol.24 , pp. 1207-1212
    • Savage, M.1    Fischmann, D.2    Schatz, R.3
  • 5
    • 0026750488 scopus 로고
    • Angiographic and clinical outcome of intracoronary stenting: Immediate and long-term results from a large single-center experience
    • Carrozza J, Kuntz R, Levine M, et al.: Angiographic and clinical outcome of intracoronary stenting: immediate and long-term results from a large single-center experience. J Am Coll Cardiol 1992, 20: 328-337.
    • (1992) J. Am. Coll. Cardiol. , vol.20 , pp. 328-337
    • Carrozza, J.1    Kuntz, R.2    Levine, M.3
  • 6
    • 0029089448 scopus 로고
    • Immediate results and late outcomes after stent implantation in saphenous vein graft lesions: The multicenter Palmaz-Schatz stent experience
    • The Palmaz-Schatz Stent Study Group
    • Wong SC, Baim DS, Schatz RA, et al.: Immediate results and late outcomes after stent implantation in saphenous vein graft lesions: the multicenter Palmaz-Schatz stent experience. The Palmaz-Schatz Stent Study Group. J Am Coll Cardiol 1995, 26: 704-712.
    • (1995) J. Am. Coll. Cardiol. , vol.26 , pp. 704-712
    • Wong, S.C.1    Baim, D.S.2    Schatz, R.A.3
  • 7
    • 0027934377 scopus 로고
    • A randomized comparison of coronary stent placement and balloon angioplasty in the treatment of coronary artery disease
    • Stent Restenosis Study investigators
    • Fischman DL, Leon MB, Baim DS, et al.: A randomized comparison of coronary stent placement and balloon angioplasty in the treatment of coronary artery disease. Stent Restenosis Study investigators. N Engl J Med 1994, 331: 496-501.
    • (1994) N. Engl. J. Med. , vol.331 , pp. 496-501
    • Fischman, D.L.1    Leon, M.B.2    Baim, D.S.3
  • 8
    • 0028123099 scopus 로고
    • A comparison of balloon-expandable stent implantation with balloon angioplasty in patients with coronary artery disease
    • BENESTENT Study group
    • Serruys PW, de Jaegere P, Kiemenjei F, et al.: A comparison of balloon-expandable stent implantation with balloon angioplasty in patients with coronary artery disease. BENESTENT Study group. N Engl J Med 1994, 331: 489-495.
    • (1994) N. Engl. J. Med. , vol.331 , pp. 489-495
    • Serruys, P.W.1    de Jaegere, P.2    Kiemenjei, F.3
  • 9
    • 0030893791 scopus 로고    scopus 로고
    • A comparison of coronary artery stenting with angioplasty for isolated stenosis of the proximal left anterior descending coronary artery
    • Versaci F, Gaspardone A, Phil M, et al.: A comparison of coronary artery stenting with angioplasty for isolated stenosis of the proximal left anterior descending coronary artery. N Engl J Med 1997, 336: 817-822.
    • (1997) N. Engl. J. Med. , vol.336 , pp. 817-822
    • Versaci, F.1    Gaspardone, A.2    Phil, M.3
  • 10
    • 0030046251 scopus 로고    scopus 로고
    • Continued benefit of coronary stenting versus balloon angioplasty: One-year clinical follow up of BENESTENT trial
    • BENESTENT Study Group
    • Macaya C, Serruys PW, Ruygrok P, et al.: Continued benefit of coronary stenting versus balloon angioplasty: one-year clinical follow up of BENESTENT trial. BENESTENT Study Group. J Am Coll Cardiol 1996, 27: 255-261.
    • (1996) J. Am. Coll. Cardiol. , vol.27 , pp. 255-261
    • Macaya, C.1    Serruys, P.W.2    Ruygrok, P.3
  • 11
    • 0033230602 scopus 로고    scopus 로고
    • Randomized comparison of coronary stent implantation and balloon angioplasty in the treatment of de novo coronary artery lesions (START): A four year follow-up
    • Betriu A, Masotti M, Serra A, et al.: Randomized comparison of coronary stent implantation and balloon angioplasty in the treatment of de novo coronary artery lesions (START): a four year follow-up. J Am Coll Cardiol 1999, 34: 1498-1506.
    • (1999) J. Am. Coll. Cardiol. , vol.34 , pp. 1498-1506
    • Betriu, A.1    Masotti, M.2    Serra, A.3
  • 12
    • 0000047784 scopus 로고    scopus 로고
    • Restenosis Stent (REST) study: Randomized trial comparing stenting and balloon angioplasty for treatment of restenosis after balloon angioplasty
    • Erbel R, Hande M, Hopp HW, et al.: Restenosis Stent (REST) study: randomized trial comparing stenting and balloon angioplasty for treatment of restenosis after balloon angioplasty. J Am Coll Cardiol 1996, 27: 139A.
    • (1996) J. Am. Coll. Cardiol. , vol.27
    • Erbel, R.1    Hande, M.2    Hopp, H.W.3
  • 14
    • 0035890318 scopus 로고    scopus 로고
    • A randomized, placebo-controlled trial of enoxaparin after high-risk coronary stenting: The ATLAST Trial
    • Batchelor WB, Mahaffey KW, Berger PB, et al.: A randomized, placebo-controlled trial of enoxaparin after high-risk coronary stenting: the ATLAST Trial. J Am Coll Cardiol 2001, 15: 1608-1613.
    • (2001) J. Am. Coll. Cardiol. , vol.15 , pp. 1608-1613
    • Batchelor, W.B.1    Mahaffey, K.W.2    Berger, P.B.3
  • 15
    • 0029837889 scopus 로고    scopus 로고
    • Patterns and mechanisms of in-stent restenosis: A serial intravascular ultrasound study
    • Hoffman R, Mintz GS, Dussaillant GR: Patterns and mechanisms of in-stent restenosis: a serial intravascular ultrasound study. Circulation 1996, 94: 1247-1254.
    • (1996) Circulation , vol.94 , pp. 1247-1254
    • Hoffman, R.1    Mintz, G.S.2    Dussaillant, G.R.3
  • 16
    • 0027254353 scopus 로고
    • Time course of restenosis during the first year after emergency coronary stenting
    • Kastrati A, Schomig A, Dietz R, Neumann FJ: Time course of restenosis during the first year after emergency coronary stenting. Circulation 1993, 87: 1498-1505.
    • (1993) Circulation , vol.87 , pp. 1498-1505
    • Kastrati, A.1    Schomig, A.2    Dietz, R.3    Neumann, F.J.4
  • 17
    • 13344293686 scopus 로고    scopus 로고
    • Three years follow-up after implantation of metallic coronary artery stents
    • Kimura T, Yokoi H, Tamura T, et al.: Three years follow-up after implantation of metallic coronary artery stents. N Engl J Med 1996, 334: 561-566.
    • (1996) N. Engl. J. Med. , vol.334 , pp. 561-566
    • Kimura, T.1    Yokoi, H.2    Tamura, T.3
  • 18
    • 0030273583 scopus 로고    scopus 로고
    • Long-term (4-6 year) outcome of Palmaz-Schatz Stenting. Paucity of late clinical stent-related problems
    • Lathan RJ, Carrozza JP, Berger JP, et al.: Long-term (4-6 year) outcome of Palmaz-Schatz Stenting. Paucity of late clinical stent-related problems. J Am Coll Cardiol 1996, 28: 820-826.
    • (1996) J. Am. Coll. Cardiol. , vol.28 , pp. 820-826
    • Lathan, R.J.1    Carrozza, J.P.2    Berger, J.P.3
  • 19
    • 0033517846 scopus 로고    scopus 로고
    • Angiographic patterns of in-stent restenosis: Classification and implication for long-term outcome
    • Mehran R, Dangas G, Abizaid AS, et al.: Angiographic patterns of in-stent restenosis: classification and implication for long-term outcome. Circulation 1999, 100: 1872-1878.
    • (1999) Circulation , vol.100 , pp. 1872-1878
    • Mehran, R.1    Dangas, G.2    Abizaid, A.S.3
  • 20
    • 0034738067 scopus 로고    scopus 로고
    • Treatment of in-stent restenosis with excimer laser coronary angioplasty vs. rotational atherectomy
    • Mehran R, Dangas G, Mintz G, et al.: Treatment of in-stent restenosis with excimer laser coronary angioplasty vs. rotational atherectomy. Circulation 2000, 101: 2484-2489.
    • (2000) Circulation , vol.101 , pp. 2484-2489
    • Mehran, R.1    Dangas, G.2    Mintz, G.3
  • 21
    • 0030587303 scopus 로고    scopus 로고
    • Mechanisms and results of balloon angioplasty for the treatment of in-stent restenosis
    • Mehran R, Mintz GS, Popma JJ, et al.: Mechanisms and results of balloon angioplasty for the treatment of in-stent restenosis. Am J Cardiol 1996, 78: 718-722.
    • (1996) Am. J. Cardiol. , vol.78 , pp. 718-722
    • Mehran, R.1    Mintz, G.S.2    Popma, J.J.3
  • 22
    • 0033517846 scopus 로고    scopus 로고
    • Angiographic patterns of in-stent restenosis: Classification and implications for long-term outcome
    • Mehran R, Dangas G, Abizaid AS, et al.: Angiographic patterns of in-stent restenosis: classification and implications for long-term outcome. Circulation 1999, 100: 1872-1878.
    • (1999) Circulation , vol.100 , pp. 1872-1878
    • Mehran, R.1    Dangas, G.2    Abizaid, A.S.3
  • 23
    • 0032191364 scopus 로고    scopus 로고
    • Balloon angioplasty for the treatment of coronary in-stent restenosis: Immediate results and 6-month angiographic recurrent restenosis rate
    • Eltchaninoff H, Koning R, Tron C, et al.: Balloon angioplasty for the treatment of coronary in-stent restenosis: immediate results and 6-month angiographic recurrent restenosis rate. J Am Coll Cardiol 1998, 32: 980-984.
    • (1998) J. Am. Coll. Cardiol. , vol.32 , pp. 980-984
    • Eltchaninoff, H.1    Koning, R.2    Tron, C.3
  • 24
    • 0032555105 scopus 로고    scopus 로고
    • Early lumen loss after treatment of in-stent restenosis. An intravascular ultrasound study
    • Shiran A, Mintz GS, Waksman R, et al.: Early lumen loss after treatment of in-stent restenosis. An intravascular ultrasound study. Circulation 1998, 98: 200-203.
    • (1998) Circulation , vol.98 , pp. 200-203
    • Shiran, A.1    Mintz, G.S.2    Waksman, R.3
  • 25
    • 0032972544 scopus 로고    scopus 로고
    • Effects of increasing balloon pressure on mechanism and results of balloon angioplasty for treatment of restenosis after Palmaz-Schatz stent implantation: An angiographic and intravascular ultrasound study
    • Schiele F, Vuillemenot A, Meneveau N, et al.: Effects of increasing balloon pressure on mechanism and results of balloon angioplasty for treatment of restenosis after Palmaz-Schatz stent implantation: an angiographic and intravascular ultrasound study. Cathet Cardiovasc Intervent 1999, 46: 314-322.
    • (1999) Cathet. Cardiovasc. Intervent. , vol.46 , pp. 314-322
    • Schiele, F.1    Vuillemenot, A.2    Meneveau, N.3
  • 26
    • 0031880355 scopus 로고    scopus 로고
    • Mechanical debulking versus balloon angioplasty for the treatment of diffuse in-stent restenosis
    • Dauerman HL, Baim DS, Cutlip DE, et al.: Mechanical debulking versus balloon angioplasty for the treatment of diffuse in-stent restenosis. Am J Cardiol 1998, 82: 277-284.
    • (1998) Am. J. Cardiol. , vol.82 , pp. 277-284
    • Dauerman, H.L.1    Baim, D.S.2    Cutlip, D.E.3
  • 27
    • 0032972798 scopus 로고    scopus 로고
    • Rotation atherectomy: Improved procedural outcome with evolution of technique and equipment. Single-center results of first 1,000 patients
    • Kini A, Marmur JD, Duvvuri S, et al.: Rotation atherectomy: improved procedural outcome with evolution of technique and equipment. Single-center results of first 1,000 patients. Catheter Cardiovasc Interv 1999, 46: 305-311.
    • (1999) Catheter. Cardiovasc. Interv. , vol.46 , pp. 305-311
    • Kini, A.1    Marmur, J.D.2    Duvvuri, S.3
  • 28
    • 0002642849 scopus 로고    scopus 로고
    • Directional coronary atherectomy is superior to PTCA for the treatment of Palmaz-Schatz stent restenosis
    • Pathan A, Butte A, Harrell L, et al.: Directional coronary atherectomy is superior to PTCA for the treatment of Palmaz-Schatz stent restenosis. J Am Coll Cardiol 1997, 29(suppl A): 68A.
    • (1997) J. Am. Coll. Cardiol. , vol.29 , Issue.SUPPL. A
    • Pathan, A.1    Butte, A.2    Harrell, L.3
  • 29
    • 0033861243 scopus 로고    scopus 로고
    • Cutting balloon angioplasty for the treatment of in-stent restenosis
    • Albiero R, Nishida T, Karvouni E, et al.: Cutting balloon angioplasty for the treatment of in-stent restenosis. Cathet Cardiovasc Intervent 2000, 50: 452-459.
    • (2000) Cathet. Cardiovasc. Intervent. , vol.50 , pp. 452-459
    • Albiero, R.1    Nishida, T.2    Karvouni, E.3
  • 30
    • 0036187877 scopus 로고    scopus 로고
    • The impact of tranilast on restenosis after coronary angioplasty: The second Tranilast Restenosis Following Angioplasty Trial (TREAT-2)
    • Tamai H, Katou K, Yamaguchi T, et al.: The impact of tranilast on restenosis after coronary angioplasty: the second Tranilast Restenosis Following Angioplasty Trial (TREAT-2). Am Heart J 2002, 143: 506-513.
    • (2002) Am. Heart J. , vol.143 , pp. 506-513
    • Tamai, H.1    Katou, K.2    Yamaguchi, T.3
  • 32
    • 0034142223 scopus 로고    scopus 로고
    • Three-year clinical and angiographic follow-up after intracoronary radiation: Results of a randomized clinical trial
    • Teirstein PS, Massullo V, Jani S, et al.: Three-year clinical and angiographic follow-up after intracoronary radiation: results of a randomized clinical trial. Circulation 2000, 101: 360-365.
    • (2000) Circulation , vol.101 , pp. 360-365
    • Teirstein, P.S.1    Massullo, V.2    Jani, S.3
  • 33
    • 17044453495 scopus 로고    scopus 로고
    • Inhibition of restenosis with beta-emitting radiotherapy: Report of the Proliferation Reduction with Vascular Energy Trial (PREVENT)
    • Raizner AE, Oesterle SN, Waksman R, et al.: Inhibition of restenosis with beta-emitting radiotherapy: report of the Proliferation Reduction with Vascular Energy Trial (PREVENT). Circulation 2000, 102: 951-958.
    • (2000) Circulation , vol.102 , pp. 951-958
    • Raizner, A.E.1    Oesterle, S.N.2    Waksman, R.3
  • 34
    • 0035945667 scopus 로고    scopus 로고
    • Localized intracoronary gamma-radiation therapy to inhibit the recurrence of restenosis after stenting
    • Leon MS, Teirstein PS, Moses JW, et al.: Localized intracoronary gamma-radiation therapy to inhibit the recurrence of restenosis after stenting. N Engl J Med 2001, 344: 350-356.
    • (2001) N. Engl. J. Med. , vol.344 , pp. 350-356
    • Leon, M.S.1    Teirstein, P.S.2    Moses, J.W.3
  • 35
    • 0032568482 scopus 로고    scopus 로고
    • Endovascular beta-radiation to reduce restenosis after coronary balloon angioplasty: Results of the Beta Energy Restenosis Trial (BERT)
    • King SB, Williams DO, Chougule P, et al.: Endovascular beta-radiation to reduce restenosis after coronary balloon angioplasty: results of the Beta Energy Restenosis Trial (BERT . Circulation 1998, 97: 2025-2030.
    • (1998) Circulation , vol.97 , pp. 2025-2030
    • King, S.B.1    Williams, D.O.2    Chougule, P.3
  • 36
    • 0034625080 scopus 로고    scopus 로고
    • Intracoronary gamma-radiation therapy after angioplasty inhibits recurrence in patients with in-stent restenosis
    • Waksman R, White RL, Chan RC, et al.: Intracoronary gamma-radiation therapy after angioplasty inhibits recurrence in patients with in-stent restenosis. Circulation 2000, 101: 2165-2171.
    • (2000) Circulation , vol.101 , pp. 2165-2171
    • Waksman, R.1    White, R.L.2    Chan, R.C.3
  • 37
    • 0343036110 scopus 로고    scopus 로고
    • Influence of diabetes on 5-year mortality and morbidity in a randomized trial comparing CABG and PTCA in patients with multivessel disease: The Bypass Angioplasty Revascularization Investigation (BARI)
    • Influence of diabetes on 5-year mortality and morbidity in a randomized trial comparing CABG and PTCA in patients with multivessel disease: the Bypass Angioplasty Revascularization Investigation (BARI . Circulation 1997, 96: 1761-1769.
    • (1997) Circulation , vol.96 , pp. 1761-1769
  • 38
    • 0029972376 scopus 로고    scopus 로고
    • Coronary angioplasty in diabetic patients: The National Heart, Lung, and Blood Institute Percutaneous Transluminal Coronary Angioplasty Registry
    • Kip KE, Faxon DP, Detre KM, et al.: Coronary angioplasty in diabetic patients: the National Heart, Lung, and Blood Institute Percutaneous Transluminal Coronary Angioplasty Registry. Circulation 1996, 94: 1818-1825.
    • (1996) Circulation , vol.94 , pp. 1818-1825
    • Kip, K.E.1    Faxon, D.P.2    Detre, K.M.3
  • 39
    • 0343852702 scopus 로고    scopus 로고
    • Predictive factors of restenosis after coronary stent placement
    • Kastrati A, Schomig A, Elezi S, et al.: Predictive factors of restenosis after coronary stent placement. J Am Coll Cardiol 1997, 30: 1428-1436.
    • (1997) J. Am. Coll. Cardiol. , vol.30 , pp. 1428-1436
    • Kastrati, A.1    Schomig, A.2    Elezi, S.3
  • 40
    • 0027479588 scopus 로고
    • Restenosis after arterial injury caused by coronary stenting in patients with diabetes mellitus
    • Carrozza JP Jr, Kunz RE, Fishman RF, Baim DS: Restenosis after arterial injury caused by coronary stenting in patients with diabetes mellitus. Ann Intern Med 1993, 118: 344-349.
    • (1993) Ann. Intern. Med. , vol.118 , pp. 344-349
    • Carrozza Jr., J.P.1    Kunz, R.E.2    Fishman, R.F.3    Baim, D.S.4
  • 41
    • 0031670506 scopus 로고    scopus 로고
    • The influence of diabetes mellitus on acute and late clinical outcomes following coronary stent implantation
    • Abizaid A, Kornowski R, Mintz GS, et al.: The influence of diabetes mellitus on acute and late clinical outcomes following coronary stent implantation. J Am Coll Cardiol 1998, 32: 584-589.
    • (1998) J. Am. Coll. Cardiol. , vol.32 , pp. 584-589
    • Abizaid, A.1    Kornowski, R.2    Mintz, G.S.3
  • 42
    • 0032406132 scopus 로고    scopus 로고
    • Diabetes mellitus and the clinical and angiographic outcome after coronary stent placement
    • Elezi S, Kastrati A, Pache J, et al.: Diabetes mellitus and the clinical and angiographic outcome after coronary stent placement. J Am Coll Cardiol 1998, 32: 1866-1873.
    • (1998) J. Am. Coll. Cardiol. , vol.32 , pp. 1866-1873
    • Elezi, S.1    Kastrati, A.2    Pache, J.3
  • 43
    • 5444232638 scopus 로고
    • Restenosis rates in diabetic patients: A comparison of coronary stenting and balloon angioplasty in native vessels
    • Van Belle E, Bauters C, Hubert E, et al.: Restenosis rates in diabetic patients: a comparison of coronary stenting and balloon angioplasty in native vessels. Circulation 1993, 118: 344-349.
    • (1993) Circulation , vol.118 , pp. 344-349
    • Van Belle, E.1    Bauters, C.2    Hubert, E.3
  • 44
    • 2242477091 scopus 로고
    • Use of a monoclonal antibody directed against the platelet glycoprotein IIb/IIIa receptor in high-risk coronary angioplasty
    • The EPIC Investigation [no authors listed]
    • Use of a monoclonal antibody directed against the platelet glycoprotein IIb/IIIa receptor in high-risk coronary angioplasty. The EPIC Investigation [no authors listed]. N Engl J Med 1994, 330: 956-961.
    • (1994) N. Engl. J. Med. , vol.330 , pp. 956-961
  • 45
    • 1842369101 scopus 로고    scopus 로고
    • Platelet glycoprotein IIb/IIIa receptor blockade and low-dose heparin during percutaneous coronary revascularization
    • The EPILOG Investigators [no authors listed]
    • Platelet glycoprotein IIb/IIIa receptor blockade and low-dose heparin during percutaneous coronary revascularization. The EPILOG Investigators [no authors listed]. N Engl J Med 1997, 336: 1689-1696.
    • (1997) N. Engl. J. Med. , vol.336 , pp. 1689-1696
  • 46
    • 0030918995 scopus 로고    scopus 로고
    • Randomized placebo-controlled trial of abciximab before and during coronary intervention in refractory unstable angina. The CAPTURE Study
    • [no authors listed]
    • Randomized placebo-controlled trial of abciximab before and during coronary intervention in refractory unstable angina. The CAPTURE Study [no authors listed]. Lancet 1997, 349: 1429-1435.
    • (1997) Lancet , vol.349 , pp. 1429-1435
  • 47
    • 0032508297 scopus 로고    scopus 로고
    • Randomized placebo-controlled and balloon-angioplasty-controlled trial to assess safety of coronary stenting with use of platelet glycoprotein IIb/IIIa blockade
    • The EPISTENT Investigators: Evaluation of Platelet IIb/IIIa Inhibitor for Stenting [no authors listed]
    • Randomized placebo-controlled and balloon-angioplasty-controlled trial to assess safety of coronary stenting with use of platelet glycoprotein IIb/IIIa blockade. The EPISTENT Investigators: Evaluation of Platelet IIb/IIIa Inhibitor for Stenting [no authors listed]. Lancet 1998, 352: 87-92.
    • (1998) Lancet , vol.352 , pp. 87-92
  • 48
    • 0033613541 scopus 로고    scopus 로고
    • Optimizing the percutaneous interventional outcomes for patients with diabetes mellitus: Results of the EPISTENT (Evaluation of Platelet IIb/IIIa inhibitor for stenting trial) Diabetic Substudy
    • Marso SP, Lincoff AM, Ellis SG, et al.: Optimizing the percutaneous interventional outcomes for patients with diabetes mellitus: results of the EPISTENT (Evaluation of Platelet IIb/IIIa inhibitor for stenting trial) Diabetic Substudy. Circulation 1999, 100: 2477-2484.
    • (1999) Circulation , vol.100 , pp. 2477-2484
    • Marso, S.P.1    Lincoff, A.M.2    Ellis, S.G.3
  • 49
  • 50
    • 0037062662 scopus 로고    scopus 로고
    • Impact of different platelet glycoprotein IIb/IIIa receptor inhibitors among diabetic patients undergoing percutaneous coronary interventions: Do Tirofiban and ReoPro Give Similar Efficacy Outcomes Trial (TARGET) 1-year follow-up?
    • Roffi M, Moliterno DJ, Meier B, et al.: Impact of different platelet glycoprotein IIb/IIIa receptor inhibitors among diabetic patients undergoing percutaneous coronary interventions: do Tirofiban and ReoPro Give Similar Efficacy Outcomes Trial (TARGET) 1-year follow-up? Circulation 2002, 105: 2730-2736.
    • (2002) Circulation , vol.105 , pp. 2730-2736
    • Roffi, M.1    Moliterno, D.J.2    Meier, B.3
  • 51
    • 0028075599 scopus 로고
    • A randomized trial comparing coronary angioplasty with coronary bypass surgery
    • King SB, Lembo NJ, Kosinski AS, et al.: A randomized trial comparing coronary angioplasty with coronary bypass surgery. N Engl J Med 1994, 331: 1044-1050.
    • (1994) N. Engl. J. Med. , vol.331 , pp. 1044-1050
    • King, S.B.1    Lembo, N.J.2    Kosinski, A.S.3
  • 52
    • 0027530879 scopus 로고
    • Coronary angioplasty versus coronary artery bypass surgery: The Randomized Intervention Treatment of Angina (RITA) trial
    • [no authors listed]
    • Coronary angioplasty versus coronary artery bypass surgery: the Randomized Intervention Treatment of Angina (RITA) trial [no authors listed]. Lancet 1993, 341: 573-580.
    • (1993) Lancet , vol.341 , pp. 573-580
  • 53
    • 0027367514 scopus 로고
    • Argentine randomized trial of percutaneous transluminal coronary angioplasty versus coronary artery bypass surgery in multi-vessel disease (ERACI): In-hospital results and 2 year follow-up
    • Rodriguez A, Boullon F, Perez-Balino N, et al.: Argentine randomized trial of percutaneous transluminal coronary angioplasty versus coronary artery bypass surgery in multi-vessel disease (ERACI): in-hospital results and 2 year follow-up. J Am Coll Cardiol 1993, 22: 1060-1067.
    • (1993) J. Am. Coll. Cardiol. , vol.22 , pp. 1060-1067
    • Rodriguez, A.1    Boullon, F.2    Perez-Balino, N.3
  • 54
    • 0028806673 scopus 로고
    • First year results of CABRI (Coronary Angioplasty vs Bypass Revascularization Investigation)
    • [no authors listed]
    • First year results of CABRI (Coronary Angioplasty vs Bypass Revascularization Investigation) [no authors listed]. Lancet 1995, 346: 1179-1184.
    • (1995) Lancet , vol.346 , pp. 1179-1184
  • 55
    • 8944262342 scopus 로고    scopus 로고
    • Comparison of coronary bypass surgery with angioplasty in patients with multivessel disease
    • BARI Investigators [no authors listed]
    • Comparison of coronary bypass surgery with angioplasty in patients with multivessel disease. BARI Investigators [no authors listed]. N Engl J Med 1996, 335: 217-225.
    • (1996) N. Engl. J. Med. , vol.335 , pp. 217-225
  • 56
    • 0034127099 scopus 로고    scopus 로고
    • Seven-year outcome in the Bypass Angioplasty Revascularization Investigation (BARI) by treatment and diabetic status
    • [no authors listed]
    • Seven-year outcome in the Bypass Angioplasty Revascularization Investigation (BARI) by treatment and diabetic status [no authors listed]. J Am Coll Cardiol 2000, 35: 1122-1129.
    • (2000) J. Am. Coll. Cardiol. , vol.35 , pp. 1122-1129
  • 57
    • 0037111947 scopus 로고    scopus 로고
    • Comparison of in-hospital and one year outcomes in patients with and without diabetes mellitus undergoing percutaneous catheter intervention (from the NHLBI Dynamic Registry)
    • Laskey WK, Selzer F, Vlachos HA, et al.: Comparison of in-hospital and one year outcomes in patients with and without diabetes mellitus undergoing percutaneous catheter intervention (from the NHLBI Dynamic Registry). Am J Cardiol 2001, 90: 1062-1067.
    • (2001) Am. J. Cardiol. , vol.90 , pp. 1062-1067
    • Laskey, W.K.1    Selzer, F.2    Vlachos, H.A.3
  • 58
    • 0034654627 scopus 로고    scopus 로고
    • Abciximab reduces mortality in diabetics following percutaneous coronary intervention
    • Rhatt DL, Maso SP, Lincoff M, et al.: Abciximab reduces mortality in diabetics following percutaneous coronary intervention. J Am Coll Cardiol 2000, 35: 922-928.
    • (2000) J. Am. Coll. Cardiol. , vol.35 , pp. 922-928
    • Rhatt, D.L.1    Maso, S.P.2    Lincoff, M.3
  • 59
    • 0037032259 scopus 로고    scopus 로고
    • Percutaneous coronary intervention versus coronary bypass graft surgery for diabetic patients with unstable angina and risk factors for adverse outcomes with bypass: Outcome of diabetic patients in the AWESOME randomized trial and registry
    • Sedlis SP, Morrison DA, Lorin JD, et al.: Percutaneous coronary intervention versus coronary bypass graft surgery for diabetic patients with unstable angina and risk factors for adverse outcomes with bypass: outcome of diabetic patients in the AWESOME randomized trial and registry. J Am Coll Cardiol 2002, 40: 1555-1566.
    • (2002) J. Am. Coll. Cardiol. , vol.40 , pp. 1555-1566
    • Sedlis, S.P.1    Morrison, D.A.2    Lorin, J.D.3
  • 60
    • 0037382142 scopus 로고    scopus 로고
    • Impact of restenosis and disease progression on clinical outcome after multivessel stenting in diabetic patients
    • Loutfi M, Mulvihill NT, Boccalatte M, et al.: Impact of restenosis and disease progression on clinical outcome after multivessel stenting in diabetic patients. Cathet Cardiovasc Intervent 2003, 58: 451-454.
    • (2003) Cathet. Cardiovasc. Intervent. , vol.58 , pp. 451-454
    • Loutfi, M.1    Mulvihill, N.T.2    Boccalatte, M.3
  • 61
    • 0037030658 scopus 로고    scopus 로고
    • A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization
    • Morice MC, Serruys PW, Sousa JE, et al.: A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med 2002, 346: 1773-1780.
    • (2002) N. Engl. J. Med. , vol.346 , pp. 1773-1780
    • Morice, M.C.1    Serruys, P.W.2    Sousa, J.E.3
  • 62
    • 0037167673 scopus 로고    scopus 로고
    • Persistent inhibition if neointimal hyperplasia after sirolimus-eluting stent implantation long-term (up to 2 years) clinical, angiographic, and intravascular ultrasound follow-up
    • Degertekin M, Serruys PW, Foley DP, et al.: Persistent inhibition if neointimal hyperplasia after sirolimus-eluting stent implantation long-term (up to 2 years) clinical, angiographic, and intravascular ultrasound follow-up. Circulation 2002, 106: 1610-1613.
    • (2002) Circulation , vol.106 , pp. 1610-1613
    • Degertekin, M.1    Serruys, P.W.2    Foley, D.P.3
  • 63
    • 0141765805 scopus 로고    scopus 로고
    • Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery
    • Moses JW, Leon MB, Popma JJ, et al.: Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med 2003, 349: 1315-1323.
    • (2003) N. Engl. J. Med. , vol.349 , pp. 1315-1323
    • Moses, J.W.1    Leon, M.B.2    Popma, J.J.3
  • 64
    • 0027508929 scopus 로고
    • Management of restenosis within the Palmaz-Schatz coronary stent (the US multicenter experience)
    • Baim DS, Levine MJ, Leon MB, et al.: Management of restenosis within the Palmaz-Schatz coronary stent (the US multicenter experience). Am J Cardiol 1993, 73:364-366.
    • (1993) Am. J. Cardiol. , vol.73 , pp. 364-366
    • Baim, D.S.1    Levine, M.J.2    Leon, M.B.3
  • 65
    • 0042388295 scopus 로고    scopus 로고
    • Randomized study to assess the effectiveness of slow and moderate-release polymer-based paclitaxel-eluting stents for coronary artery lesions
    • Colombo A, Drzewiecki J, Banning A, et al.: Randomized study to assess the effectiveness of slow and moderate-release polymer-based paclitaxel-eluting stents for coronary artery lesions. Circulation 2003, 108: 788-794.
    • (2003) Circulation , vol.108 , pp. 788-794
    • Colombo, A.1    Drzewiecki, J.2    Banning, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.