Volumn 31, Issue 3, 2005, Pages 459-460

Effect of 1-piece and 3-piece AcrySof IOLs on the development of PCO after cataract surgery [4]

(1)  Olson, Randall J a  

a NONE

Author keywords

[No Author keywords available]

Indexed keywords

CATARACT; CATARACT EXTRACTION; DATA ANALYSIS; EPITHELIUM CELL; FOLLOW UP; HUMAN; HYPOTHESIS; LENS IMPLANT; LETTER; NONHUMAN; OBSERVATION; PRIORITY JOURNAL; STATISTICAL SIGNIFICANCE;

EID: 16344384877     PISSN: 08863350     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcrs.2005.02.026     Document Type: Letter
Times cited : (2)

References (4)
  • 1
    • 16344365705 scopus 로고    scopus 로고
    • Effect of 1-piece and 3-piece AcrySof intraocular lenses on the development of posterior capsule opacification after cataract surgery
    • L.E. Bender, C. Nimsgern, and R. Jose Effect of 1-piece and 3-piece AcrySof intraocular lenses on the development of posterior capsule opacification after cataract surgery J Cataract Refract Surg 30 2004 786 789
    • (2004) J Cataract Refract Surg , vol.30 , pp. 786-789
    • Bender, L.E.1    Nimsgern, C.2    Jose, R.3
  • 2
    • 0141458945 scopus 로고    scopus 로고
    • A clinical comparison of single-piece and three-piece truncated hydrophobic acrylic intraocular lenses
    • T.R. Wallin, M. Hinckley, C. Nilcon, and R. Olson A clinical comparison of single-piece and three-piece truncated hydrophobic acrylic intraocular lenses Am J Ophthalmol 136 2003 614 619
    • (2003) Am J Ophthalmol , vol.136 , pp. 614-619
    • Wallin, T.R.1    Hinckley, M.2    Nilcon, C.3    Olson, R.4
  • 3
    • 0037325768 scopus 로고    scopus 로고
    • Effect of the optic size of a single-piece acrylic intraocular lens on posterior capsule opacification
    • O. Nishi, and K. Nishi Effect of the optic size of a single-piece acrylic intraocular lens on posterior capsule opacification J Cataract Refract Surg 29 2003 348 353
    • (2003) J Cataract Refract Surg , vol.29 , pp. 348-353
    • Nishi, O.1    Nishi, K.2
  • 4
    • 1242271200 scopus 로고    scopus 로고
    • Migration of lens epithelial cells through haptic root of single-piece acrylic foldable intraocular lens
    • M. Sugita, S. Kato, G. Sugito, and T. Oshika Migration of lens epithelial cells through haptic root of single-piece acrylic foldable intraocular lens Am J Ophthalmol 137 2004 377 379
    • (2004) Am J Ophthalmol , vol.137 , pp. 377-379
    • Sugita, M.1    Kato, S.2    Sugito, G.3    Oshika, T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.