메뉴 건너뛰기




Volumn 38, Issue 5, 2005, Pages 769-780

Amperometric detection of glucose involving electropolymerized tetraaminophthalocyanine and ferrocene films

Author keywords

Chemically modified electrodes; Electropolymerization; Ferrocene; Glucose

Indexed keywords

4,9,16,23 TETRAAMINOPHTHALOCYANINE; CARBON; DIMETHYL SULFOXIDE; ELECTROLYTE; FERROCENE DERIVATIVE; GLUCOSE; GLUCOSE OXIDASE; PHTHALOCYANINE DERIVATIVE; POLYMER; TETRYLAMMONIUM; UNCLASSIFIED DRUG;

EID: 16344378775     PISSN: 00032719     EISSN: None     Source Type: Journal    
DOI: 10.1081/AL-200051020     Document Type: Article
Times cited : (7)

References (19)
  • 1
    • 0031275746 scopus 로고    scopus 로고
    • The electroreduction of carbon dioxide by macrocyclic cobalt complexes chemically modified on a glassy carbon electrode
    • Aga, A., Aramata, A., and Hisaeda, Y. 1997. The electroreduction of carbon dioxide by macrocyclic cobalt complexes chemically modified on a glassy carbon electrode. J. Electroanal. Chem., 437: 111-18.
    • (1997) J. Electroanal. Chem. , vol.437 , pp. 111-118
    • Aga, A.1    Aramata, A.2    Hisaeda, Y.3
  • 2
    • 0033104279 scopus 로고    scopus 로고
    • Effect of ionic strength on the behavior of amperometric enzyme electrodes mediated by redox hyrogels
    • Battaglini, F., Calvo, E.J., Danilowiez, C., and Wolosiuk, A. 1999. Effect of ionic strength on the behavior of amperometric enzyme electrodes mediated by redox hyrogels. Anal. Chem., 71: 1062-67.
    • (1999) Anal. Chem. , vol.71 , pp. 1062-1067
    • Battaglini, F.1    Calvo, E.J.2    Danilowiez, C.3    Wolosiuk, A.4
  • 3
    • 0032499610 scopus 로고    scopus 로고
    • Voltammetric, chronocoulometric, and spectroelectrochemical studies of electropolymerized films based on Co(II/I)-4,9,16,23- Tetraaminophthalocyanine
    • Brown, K.L. and Mottola, H.A. 1998. Voltammetric, chronocoulometric, and spectroelectrochemical studies of electropolymerized films based on Co(II/I)-4,9,16,23- Tetraaminophthalocyanine. Langmuir, 14: 3411-17.
    • (1998) Langmuir , vol.14 , pp. 3411-3417
    • Brown, K.L.1    Mottola, H.A.2
  • 4
    • 0036754325 scopus 로고    scopus 로고
    • Voltammetric, chronocoulometric, and spectroelectrochemical studies of electropolymerized films based on Co(III/II)- and Zn(II)-4,9,16,23- Tetraaminophthalocyanine: Effect of high pH
    • Brown, K.L., Shaw, J., Ambrose, M., and Horacio, H.A. 2002. Voltammetric, chronocoulometric, and spectroelectrochemical studies of electropolymerized films based on Co(III/II)- and Zn(II)-4,9,16,23-Tetraaminophthalocyanine: effect of high pH. Microchem. J., 72: 285-98.
    • (2002) Microchem. J. , vol.72 , pp. 285-298
    • Brown, K.L.1    Shaw, J.2    Ambrose, M.3    Horacio, H.A.4
  • 5
    • 0031374233 scopus 로고    scopus 로고
    • First-row transition metal phthalocyanines as catalysts for water electrolysis: A comparative study
    • Chebotareva, N. and Nyokong, T. 1997. First-row transition metal phthalocyanines as catalysts for water electrolysis: a comparative study. Electrochim. Acta, 42: 3519-24.
    • (1997) Electrochim. Acta , vol.42 , pp. 3519-3524
    • Chebotareva, N.1    Nyokong, T.2
  • 6
    • 0027258327 scopus 로고
    • Flow-injection analysis of glucose at an amperometric glucose biosensor based on electrochemical codeposition of Palladium and Glucose oxidase on a glassy carbon electrode
    • Chi, Q. and Dong, S. 1993. Flow-injection analysis of glucose at an amperometric glucose biosensor based on electrochemical codeposition of Palladium and Glucose oxidase on a glassy carbon electrode. Anal. Chim. Acta, 278: 17-23.
    • (1993) Anal. Chim. Acta , vol.278 , pp. 17-23
    • Chi, Q.1    Dong, S.2
  • 7
    • 0030696341 scopus 로고    scopus 로고
    • Amperometric glucose sensors based on ferrocene-containing B-polyethylenimine and immobilized glucose oxidase
    • Chuang, C.L., Wang, Y.J., and Lan, H.L. 1997. Amperometric glucose sensors based on ferrocene-containing B-polyethylenimine and immobilized glucose oxidase. Anal. Chim. Acta, 353: 37-44.
    • (1997) Anal. Chim. Acta , vol.353 , pp. 37-44
    • Chuang, C.L.1    Wang, Y.J.2    Lan, H.L.3
  • 8
    • 0029029571 scopus 로고
    • Self-assembled monolayers and enzyme electrodes: Progress, problems, and prospects
    • Creager, S.E. and Olsen, K.G. 1995. Self-assembled monolayers and enzyme electrodes: progress, problems, and prospects. Anal. Chim. Acta, 307: 277-89.
    • (1995) Anal. Chim. Acta , vol.307 , pp. 277-289
    • Creager, S.E.1    Olsen, K.G.2
  • 9
    • 0026523045 scopus 로고
    • Amperometric glucose sensor with ferrocene as an electron transfer mediator
    • Dong, S., Wang, B., and Liu, B. 1991. Amperometric glucose sensor with ferrocene as an electron transfer mediator. Biosen. Bioelectron., 7: 215-22.
    • (1991) Biosen. Bioelectron. , vol.7 , pp. 215-222
    • Dong, S.1    Wang, B.2    Liu, B.3
  • 10
    • 0031835289 scopus 로고    scopus 로고
    • Enzymatic determinations with rotating bioreactors: Determination of glutamate in food products
    • Janarthanan. C. and Mottola, H.A. 1998. Enzymatic determinations with rotating bioreactors: determination of glutamate in food products. Anal. Chim. Acta., 369: 147-55.
    • (1998) Anal. Chim. Acta. , vol.369 , pp. 147-155
    • Janarthanan, C.1    Mottola, H.A.2
  • 11
    • 0030723770 scopus 로고    scopus 로고
    • Potentiometric pH sensors based on chemically modified electrodes with electropolymerized metal-tetraaminophthalocyanine
    • Kang, T.F., Xie, Z.-Y., Tang, H., Shen, G.-L., and Yu, R.-Q. 1997. Potentiometric pH sensors based on chemically modified electrodes with electropolymerized metal-tetraaminophthalocyanine. Talanta, 45: 291-96.
    • (1997) Talanta , vol.45 , pp. 291-296
    • Kang, T.F.1    Xie, Z.-Y.2    Tang, H.3    Shen, G.-L.4    Yu, R.-Q.5
  • 12
    • 37049075284 scopus 로고
    • Formation of electronically conductive thin films of metal phthalocyanines via electropolymerization
    • Li, H. and Guarr, T.F. 1989. Formation of electronically conductive thin films of metal phthalocyanines via electropolymerization. J. Chem. Soc. Chem. Commun., 13: 832-34.
    • (1989) J. Chem. Soc. Chem. Commun. , vol.13 , pp. 832-834
    • Li, H.1    Guarr, T.F.2
  • 13
    • 0026096659 scopus 로고
    • Use of Cobalt(II) phthalocyanine to improve the sensitivity and stability of glassy carbon electrodes for the detection of cresols, chlorophenol and phenol
    • Li, H. and Guarr, T.F. 1991. Use of Cobalt(II) phthalocyanine to improve the sensitivity and stability of glassy carbon electrodes for the detection of cresols, chlorophenol and phenol. J. Electroanal. Chem., 297: 169-83.
    • (1991) J. Electroanal. Chem. , vol.297 , pp. 169-183
    • Li, H.1    Guarr, T.F.2
  • 14
    • 16344392205 scopus 로고    scopus 로고
    • Amperometric glucose sensors fabricated by electrochemical polymerization of phenols on carbon paste electrodes containing ferrocene as an electron transfer mediator
    • Mafatle, T. and Nyokong, T. 1997. Amperometric glucose sensors fabricated by electrochemical polymerization of phenols on carbon paste electrodes containing ferrocene as an electron transfer mediator. Anal. Chim. Acta, 42: 307-14.
    • (1997) Anal. Chim. Acta , vol.42 , pp. 307-314
    • Mafatle, T.1    Nyokong, T.2
  • 15
    • 0032281882 scopus 로고    scopus 로고
    • "Wired" enzyme electrodes for amperometric determination of glucose for lactate in the presence of interfering substances
    • Nakabayashi, Y., Wakuda, M., and Imai, H. 1998. "Wired" enzyme electrodes for amperometric determination of glucose for lactate in the presence of interfering substances. Anal. Sci., 14: 1069-76.
    • (1998) Anal. Sci. , vol.14 , pp. 1069-1076
    • Nakabayashi, Y.1    Wakuda, M.2    Imai, H.3
  • 16
    • 0028489808 scopus 로고
    • Spectrophotometric cell comprising parallel rotating and stationary bioreactors: Application to the determination of glucose in serum samples
    • Ohara, T.J., Rajagopalan, R., and Heller, A. 1994. Spectrophotometric cell comprising parallel rotating and stationary bioreactors: application to the determination of glucose in serum samples. Anal. Chem., 66: 2451-2457.
    • (1994) Anal. Chem. , vol.66 , pp. 2451-2457
    • Ohara, T.J.1    Rajagopalan, R.2    Heller, A.3
  • 17
    • 0028887427 scopus 로고
    • Electrochemical responses of electrodes coated with redox polymers. Evidence for control of charge-transfer rates across polymeric layers by electron exchange between incorporated redox sites
    • Raba, J., Li, S., and Mottola, H.A. 1995. Electrochemical responses of electrodes coated with redox polymers. Evidence for control of charge-transfer rates across polymeric layers by electron exchange between incorporated redox sites. Anal. Chim. Acta, 300: 299-305.
    • (1995) Anal. Chim. Acta , vol.300 , pp. 299-305
    • Raba, J.1    Li, S.2    Mottola, H.A.3
  • 18
    • 33845556917 scopus 로고
    • Electrocatalytic reduction and flow injection analysis or organic peroxides at polymeric tetra-amino iron phthalocyanine modified electrode
    • Shigehara, K., Oyama, N., and Anson, F.C. 1981. Electrocatalytic reduction and flow injection analysis or organic peroxides at polymeric tetra-amino iron phthalocyanine modified electrode. J. Am. Chem. Soc., 103: 2552-58.
    • (1981) J. Am. Chem. Soc. , vol.103 , pp. 2552-2558
    • Shigehara, K.1    Oyama, N.2    Anson, F.C.3
  • 19
    • 0000380985 scopus 로고    scopus 로고
    • Wang, J. 1996. Anal. Lett., 29: 1575-87.
    • (1996) Anal. Lett. , vol.29 , pp. 1575-1587
    • Wang, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.