Volumn 31, Issue 3, 2005, Pages 467-471

Closed foldable capsular rings

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CATARACT; CONTROLLED STUDY; FOLLOW UP; HUMAN; LENS CAPSULE; LENS IMPLANT; PEROPERATIVE COMPLICATION; POSTOPERATIVE COMPLICATION; PRIORITY JOURNAL; SURGICAL TECHNIQUE;

EID: 16344370558     PISSN: 08863350     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcrs.2004.12.047     Document Type: Article
Times cited : (17)

References (24)
  • 1
    • 0025784515 scopus 로고
    • "Equator ring" for maintenance of the completely circular contour of the capsular bag equator after cataract removal
    • T. Hara, T. Hara, and Y. Yamada "Equator ring" for maintenance of the completely circular contour of the capsular bag equator after cataract removal Ophthalmic Surg 22 1991 358 359
    • (1991) Ophthalmic Surg , vol.22 , pp. 358-359
    • Hara, T.1    Hara, T.2    Yamada, Y.3
  • 2
    • 0028805830 scopus 로고
    • Efficacy of equator rings in an experimental rabbit study
    • T. Hara, T. Hara, K. Sakanishi, and Y. Yamada Efficacy of equator rings in an experimental rabbit study Arch Ophthalmol 113 1995 1060 1065
    • (1995) Arch Ophthalmol , vol.113 , pp. 1060-1065
    • Hara, T.1    Hara, T.2    Sakanishi, K.3    Yamada, Y.4
  • 3
    • 0000866564 scopus 로고
    • The capsular ring: A new device for complicated cataract surgery. Abstract F12
    • U.F.C. Legler, and B.M. Witschel The capsular ring: a new device for complicated cataract surgery. Abstract F12 Gerr J Ophthalmol 3 1994 265
    • (1994) Gerr J Ophthalmol , vol.3 , pp. 265
    • Legler, U.F.C.1    Witschel, B.M.2
  • 4
    • 0030988566 scopus 로고    scopus 로고
    • Management of zonular dialysis in phacoemulsification and IOL implantation using the capsular tension ring
    • H.V. Gimbel, R. Sun, and J.P. Heston Management of zonular dialysis in phacoemulsification and IOL implantation using the capsular tension ring Ophthalmic Surg Lasers 28 1997 273 281
    • (1997) Ophthalmic Surg Lasers , vol.28 , pp. 273-281
    • Gimbel, H.V.1    Sun, R.2    Heston, J.P.3
  • 5
    • 0031778562 scopus 로고    scopus 로고
    • In vitro evaluation of the efficacy of the capsular tension ring for managing zonular dialysis in cataract surgery
    • R. Sun, and H.V. Gimbel In vitro evaluation of the efficacy of the capsular tension ring for managing zonular dialysis in cataract surgery Ophthalmic Surg Lasers 29 1998 502 505
    • (1998) Ophthalmic Surg Lasers , vol.29 , pp. 502-505
    • Sun, R.1    Gimbel, H.V.2
  • 6
    • 0029024085 scopus 로고
    • Endocapsular ring approach to the subluxed cataractous lens
    • R.J. Cionni, and R.H. Osher Endocapsular ring approach to the subluxed cataractous lens J Cataract Refract Surg 21 1995 245 249
    • (1995) J Cataract Refract Surg , vol.21 , pp. 245-249
    • Cionni, R.J.1    Osher, R.H.2
  • 7
    • 0031659486 scopus 로고    scopus 로고
    • Management of profound zonular dialysis or weakness with a new endocapsular ring designed for scleral fixation
    • R.J. Cionni, and R.H. Osher Management of profound zonular dialysis or weakness with a new endocapsular ring designed for scleral fixation J Cataract Refract Surg 24 1998 1299 1306
    • (1998) J Cataract Refract Surg , vol.24 , pp. 1299-1306
    • Cionni, R.J.1    Osher, R.H.2
  • 8
    • 0033942575 scopus 로고    scopus 로고
    • The capsular tension ring: Designs, applications, and techniques
    • R. Menapace, O. Findl, and M. Georgopoulos The capsular tension ring: designs, applications, and techniques J Cataract Refract Surg 26 2000 898 912
    • (2000) J Cataract Refract Surg , vol.26 , pp. 898-912
    • Menapace, R.1    Findl, O.2    Georgopoulos, M.3
  • 9
    • 0031443888 scopus 로고    scopus 로고
    • Capsular bag shrinkage after implantation of an open-loop silicone lens and a poly(methyl methacrylate) capsule tension ring
    • K. Strenn, R. Menapace, and C. Vass Capsular bag shrinkage after implantation of an open-loop silicone lens and a poly(methyl methacrylate) capsule tension ring J Cataract Refract Surg 23 1997 1543 1547
    • (1997) J Cataract Refract Surg , vol.23 , pp. 1543-1547
    • Strenn, K.1    Menapace, R.2    Vass, C.3
  • 10
    • 0030824089 scopus 로고    scopus 로고
    • Effect of intraocular lens design on migration of lens epithelial cells onto the posterior capsule
    • T. Nagamoto, and G. Eguchi Effect of intraocular lens design on migration of lens epithelial cells onto the posterior capsule J Cataract Refract Surg 23 1997 866 872
    • (1997) J Cataract Refract Surg , vol.23 , pp. 866-872
    • Nagamoto, T.1    Eguchi, G.2
  • 11
    • 0036141477 scopus 로고    scopus 로고
    • Clinical applications of capsular tension rings in cataract surgery
    • H.V. Gimbel, and R. Sun Clinical applications of capsular tension rings in cataract surgery Ophthalmic Surg Lasers 33 2002 44 53
    • (2002) Ophthalmic Surg Lasers , vol.33 , pp. 44-53
    • Gimbel, H.V.1    Sun, R.2
  • 12
    • 0036233920 scopus 로고    scopus 로고
    • Effect of a capsular tension ring on intraocular lens decentration and tilting after cataract surgery
    • D.-H. Lee, S.-C. Shin, and C.-K. Joo Effect of a capsular tension ring on intraocular lens decentration and tilting after cataract surgery J Cataract Refract Surg 28 2002 843 846
    • (2002) J Cataract Refract Surg , vol.28 , pp. 843-846
    • Lee, D.-H.1    Shin, S.-C.2    Joo, C.-K.3
  • 13
    • 0028236431 scopus 로고
    • A ring to support the capsular bag after continuous curvilinear capsulorhexis
    • T. Nagamoto, and H. Bissen-Miyajima A ring to support the capsular bag after continuous curvilinear capsulorhexis J Cataract Refract Surg 20 1994 417 420
    • (1994) J Cataract Refract Surg , vol.20 , pp. 417-420
    • Nagamoto, T.1    Bissen-Miyajima, H.2
  • 14
    • 0037352371 scopus 로고    scopus 로고
    • Chronic cystoid macular edema in an eye with a capsule defect and posteriorly dislocated capsular tension ring
    • S. Bopp, and K. Lucke Chronic cystoid macular edema in an eye with a capsule defect and posteriorly dislocated capsular tension ring J Cataract Refract Surg 29 2003 603 608
    • (2003) J Cataract Refract Surg , vol.29 , pp. 603-608
    • Bopp, S.1    Lucke, K.2
  • 15
    • 0035085318 scopus 로고    scopus 로고
    • Vitrectomy to remove a posteriorly dislocated endocapsular tension ring
    • Y. Lang, E. Fineberg, and H.J. Garzozi Vitrectomy to remove a posteriorly dislocated endocapsular tension ring J Cataract Refract Surg 27 2001 474 476
    • (2001) J Cataract Refract Surg , vol.27 , pp. 474-476
    • Lang, Y.1    Fineberg, E.2    Garzozi, H.J.3
  • 16
    • 0032883651 scopus 로고    scopus 로고
    • Prediction of pseudophakic capsular bag diameter based on biometric variables
    • C. Vass, R. Menapace, and K. Schmetterer Prediction of pseudophakic capsular bag diameter based on biometric variables J Cataract Refract Surg 25 1999 1376 1381
    • (1999) J Cataract Refract Surg , vol.25 , pp. 1376-1381
    • Vass, C.1    Menapace, R.2    Schmetterer, K.3
  • 17
    • 0346749582 scopus 로고    scopus 로고
    • Capsule measuring ring to predict capsular bag diameter and follow its course after foldable intraocular lens implantation
    • M. Tehrani, H.B. Dick, and F. Krummenauer Capsule measuring ring to predict capsular bag diameter and follow its course after foldable intraocular lens implantation J Cataract Refract Surg 29 2003 2127 2134
    • (2003) J Cataract Refract Surg , vol.29 , pp. 2127-2134
    • Tehrani, M.1    Dick, H.B.2    Krummenauer, F.3
  • 18
    • 0031899915 scopus 로고    scopus 로고
    • Equator ring: Efficacy in maintaining capsular bag integrity and transparency after cataract removal in monkey eyes
    • M. Hasiozoe, T. Hara, and Y. Ogura Equator ring: efficacy in maintaining capsular bag integrity and transparency after cataract removal in monkey eyes Graefes Arch Clin Exp Ophthalmol 236 1998 531 536
    • (1998) Graefes Arch Clin Exp Ophthalmol , vol.236 , pp. 531-536
    • Hasiozoe, M.1    Hara, T.2    Ogura, Y.3
  • 19
    • 0031890039 scopus 로고    scopus 로고
    • The inhibition of lens epithelial cell migration by a discontinuous capsular bend created by a band-shaped circular loop or a capsule-bending ring
    • O. Nishi, K. Nishi, and C. Mano The inhibition of lens epithelial cell migration by a discontinuous capsular bend created by a band-shaped circular loop or a capsule-bending ring Ophthalmic Surg Lasers 29 1998 119 125
    • (1998) Ophthalmic Surg Lasers , vol.29 , pp. 119-125
    • Nishi, O.1    Nishi, K.2    Mano, C.3
  • 20
    • 0034827421 scopus 로고    scopus 로고
    • Capsular bending ring to prevent posterior capsule opacification: 2 year follow-up
    • O. Nishi, K. Nishi, R. Menapace, and J. Akura Capsular bending ring to prevent posterior capsule opacification: 2 year follow-up J Cataract Refract Surg 27 2001 1359 1365
    • (2001) J Cataract Refract Surg , vol.27 , pp. 1359-1365
    • Nishi, O.1    Nishi, K.2    Menapace, R.3    Akura, J.4
  • 21
    • 0032693403 scopus 로고    scopus 로고
    • Implantation of the modified endocapsular bending ring in pediatric cataract surgery using a viscoadaptive visoelastic agent
    • H.B. Dick, O. Schwenn, and N. Pfeiffer Implantation of the modified endocapsular bending ring in pediatric cataract surgery using a viscoadaptive visoelastic agent J Cataract Refract Surg 25 1999 1432 1436
    • (1999) J Cataract Refract Surg , vol.25 , pp. 1432-1436
    • Dick, H.B.1    Schwenn, O.2    Pfeiffer, N.3
  • 22
    • 0035088112 scopus 로고    scopus 로고
    • Experimental studies of capsular equator rings of soft latex
    • E.I. Assia, M. Shelach, and H.M. Israel Experimental studies of capsular equator rings of soft latex J Cataract Refract Surg 27 2001 457 462
    • (2001) J Cataract Refract Surg , vol.27 , pp. 457-462
    • Assia, E.I.1    Shelach, M.2    Israel, H.M.3
  • 23
    • 0027301363 scopus 로고
    • Capsule contraction syndrome
    • J.A. Davison Capsule contraction syndrome J Cataract Refract Surg 19 1993 582 589
    • (1993) J Cataract Refract Surg , vol.19 , pp. 582-589
    • Davison, J.A.1
  • 24
    • 0033048756 scopus 로고    scopus 로고
    • Complete capsulorhexis opening occlusion despite capsular tension ring implantation
    • C.W. Faschinger, and M. Eckhardt Complete capsulorhexis opening occlusion despite capsular tension ring implantation J Cataract Refract Surg 25 1999 1013 1015
    • (1999) J Cataract Refract Surg , vol.25 , pp. 1013-1015
    • Faschinger, C.W.1    Eckhardt, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.