메뉴 건너뛰기




Volumn 31, Issue 3, 2005, Pages 543-547

Association between intensity of posterior capsule opacification and visual acuity

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; AUSTRIA; AUTOANALYSIS; CALCULATION; CAPSULOTOMY; CATARACT; CLINICAL ARTICLE; CORRELATION ANALYSIS; DIABETIC RETINOPATHY; DISEASE SEVERITY; HUMAN; ILLUMINATION; IMAGE ANALYSIS; NEODYMIUM LASER; PRIORITY JOURNAL; PSEUDOPHAKIA; PUPIL; READING; VISION TEST; VISUAL ACUITY;

EID: 16344363584     PISSN: 08863350     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcrs.2004.05.060     Document Type: Article
Times cited : (28)

References (12)
  • 1
    • 13144282668 scopus 로고    scopus 로고
    • A systematic overview of the incidence of posterior capsule opacification
    • D.A. Schaumberg, M.R. Dana, W.G. Christen, and R.J. Glynn A systematic overview of the incidence of posterior capsule opacification Ophthalmology 105 1998 1213 1221
    • (1998) Ophthalmology , vol.105 , pp. 1213-1221
    • Schaumberg, D.A.1    Dana, M.R.2    Christen, W.G.3    Glynn, R.J.4
  • 3
    • 0033760066 scopus 로고    scopus 로고
    • Quantification of posterior capsular opacification in digital images after cataract surgery
    • S.A. Barman, E.J. Hollick, and J.F. Boyce Quantification of posterior capsular opacification in digital images after cataract surgery Invest Ophthalmol Vis Sci 41 2000 3882 3892
    • (2000) Invest Ophthalmol Vis Sci , vol.41 , pp. 3882-3892
    • Barman, S.A.1    Hollick, E.J.2    Boyce, J.F.3
  • 4
    • 0031899326 scopus 로고    scopus 로고
    • Relationship between intraocular lens biomaterials and posterior capsule opacification
    • P.G. Ursell, D.J. Spalton, and M.V. Pande Relationship between intraocular lens biomaterials and posterior capsule opacification J Cataract Refract Surg 24 1998 352 360
    • (1998) J Cataract Refract Surg , vol.24 , pp. 352-360
    • Ursell, P.G.1    Spalton, D.J.2    Pande, M.V.3
  • 5
    • 0037257792 scopus 로고    scopus 로고
    • Comparison of 4 methods for quantifying posterior capsule opacification
    • O. Findl, W. Buehl, and R. Menapace Comparison of 4 methods for quantifying posterior capsule opacification J Cataract Refract Surg 29 2003 106 111
    • (2003) J Cataract Refract Surg , vol.29 , pp. 106-111
    • Findl, O.1    Buehl, W.2    Menapace, R.3
  • 6
    • 0036166274 scopus 로고    scopus 로고
    • Reproducibility of standardized retroillumination photography for quantification of regeneratory posterior capsule opacification
    • W. Buehl, O. Findl, and R. Menapace Reproducibility of standardized retroillumination photography for quantification of regeneratory posterior capsule opacification J Cataract Refract Surg 28 2002 265 270
    • (2002) J Cataract Refract Surg , vol.28 , pp. 265-270
    • Buehl, W.1    Findl, O.2    Menapace, R.3
  • 7
    • 0030793930 scopus 로고    scopus 로고
    • Proper method for calculating average visual acuity
    • J.T. Holladay Proper method for calculating average visual acuity J Cataract Refract Surg 13 1997 388 391
    • (1997) J Cataract Refract Surg , vol.13 , pp. 388-391
    • Holladay, J.T.1
  • 8
    • 0037251279 scopus 로고    scopus 로고
    • Removal of reflections in the photographic assessment of PCO by fusion of digital retroillumination images
    • O. Findl, W. Buehl, H. Siegl, and A. Pinz Removal of reflections in the photographic assessment of PCO by fusion of digital retroillumination images Invest Ophthalmol Vis Sci 44 2003 275 280
    • (2003) Invest Ophthalmol Vis Sci , vol.44 , pp. 275-280
    • Findl, O.1    Buehl, W.2    Siegl, H.3    Pinz, A.4
  • 9
    • 0141681933 scopus 로고    scopus 로고
    • Correlation between posterior capsule opacification and visual function before and after neodymium:YAG laser posterior capsulotomy
    • K. Hayashi, H. Hayashi, F. Nakao, and F. Hayashi Correlation between posterior capsule opacification and visual function before and after neodymium:YAG laser posterior capsulotomy Am J Ophthalmol 136 2003 720 726
    • (2003) Am J Ophthalmol , vol.136 , pp. 720-726
    • Hayashi, K.1    Hayashi, H.2    Nakao, F.3    Hayashi, F.4
  • 12
    • 0032100759 scopus 로고    scopus 로고
    • In vivo quantitative measurement of posterior capsule opacification after extracapsular cataract surgery
    • K. Hayashi, H. Hayashi, F. Nakao, and F. Hayashi In vivo quantitative measurement of posterior capsule opacification after extracapsular cataract surgery Am J Ophthalmol 125 1998 837 843
    • (1998) Am J Ophthalmol , vol.125 , pp. 837-843
    • Hayashi, K.1    Hayashi, H.2    Nakao, F.3    Hayashi, F.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.