메뉴 건너뛰기




Volumn 37, Issue 1, 2005, Pages 172-174

Preliminary evaluation of a new chemiluminescence assay (Liaison cyclosporine; Diasorin Laboratories) allowing both C0 and C2 cyclosporine levels determination: Comparison with RIA method

Author keywords

[No Author keywords available]

Indexed keywords

CYCLOSPORIN A; RADIOISOTOPE;

EID: 16244408330     PISSN: 00411345     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.transproceed.2004.12.193     Document Type: Conference Paper
Times cited : (4)

References (12)
  • 1
    • 0035113430 scopus 로고    scopus 로고
    • New developments in the immunosuppressive drug monitoring of cyclosporin: A, tacrolimus and azathioprine
    • V.W. Armstrong, M. Oellerich New developments in the immunosuppressive drug monitoring of cyclosporin A, tacrolimus and azathioprine Clin Biochem 34 2001 9
    • (2001) Clin Biochem , vol.34 , pp. 9
    • Armstrong, V.W.1    Oellerich, M.2
  • 2
    • 0031863345 scopus 로고    scopus 로고
    • Two-hour cyclosporin level determination is the appropriate tool to monitor Neoral therapy
    • M. Cantarovich, J.G. Besner, J.S. Barkun Two-hour cyclosporin level determination is the appropriate tool to monitor Neoral therapy Clin Transplant 12 1998 243
    • (1998) Clin Transplant , vol.12 , pp. 243
    • Cantarovich, M.1    Besner, J.G.2    Barkun, J.S.3
  • 3
    • 0037093449 scopus 로고    scopus 로고
    • Recommendations for the implementation of Neoral C2 monitoring in clinical practice
    • E. Cole, K. Midtvedt, A. Johnston Recommendations for the implementation of Neoral C2 monitoring in clinical practice Transplantation 73 suppl 9 2002 S.19
    • (2002) Transplantation , vol.73 , Issue.9 SUPPL. , pp. 19
    • Cole, E.1    Midtvedt, K.2    Johnston, A.3
  • 4
    • 0037774756 scopus 로고    scopus 로고
    • Clinical benefits of Neoral C2 monitoring in the long-term management of renal transplant recipients
    • E. Cole, N. Maham, C. Cardella Clinical benefits of Neoral C2 monitoring in the long-term management of renal transplant recipients Transplantation 75 2003 2086
    • (2003) Transplantation , vol.75 , pp. 2086
    • Cole, E.1    Maham, N.2    Cardella, C.3
  • 5
    • 2442595887 scopus 로고    scopus 로고
    • C2 monitoring of cyclosporine in de novo liver transplant recipients: The clinician's perspective
    • F. Villamil, S. Pollard C2 monitoring of cyclosporine in de novo liver transplant recipients: the clinician's perspective Liver Transpl 10 2004 577
    • (2004) Liver Transpl , vol.10 , pp. 577
    • Villamil, F.1    Pollard, S.2
  • 6
    • 0024563874 scopus 로고
    • A rapid, reliable high-performance liquid chromatographic micromethod for the measurement of cyclosporine in whole blood
    • E.E. Giesbrecht, S.J. Soldin, P.Y. Wong A rapid, reliable high-performance liquid chromatographic micromethod for the measurement of cyclosporine in whole blood Ther Drug Monit 11 1989 332
    • (1989) Ther Drug Monit , vol.11 , pp. 332
    • Giesbrecht, E.E.1    Soldin, S.J.2    Wong, P.Y.3
  • 7
    • 0035921161 scopus 로고    scopus 로고
    • Evaluation and comparison of therapeutic monitoring of whole-blood levels of cyclosporin a and its metabolites in renal transplantation by HPLC and RIA methods
    • K. Safarcik, H. Brozmanova, V. Bartos Evaluation and comparison of therapeutic monitoring of whole-blood levels of cyclosporin A and its metabolites in renal transplantation by HPLC and RIA methods Clin Chim Acta 310 2001 165
    • (2001) Clin Chim Acta , vol.310 , pp. 165
    • Safarcik, K.1    Brozmanova, H.2    Bartos, V.3
  • 8
    • 0027060563 scopus 로고
    • Recommendations for a comparison of techniques: Document F, stage 3
    • A. Vassault, M. Baud, M. Castanier Recommendations for a comparison of techniques Document F, stage 3 Ann Biol Clin (Paris) 50 1992 727
    • (1992) Ann Biol Clin (Paris) , vol.50 , pp. 727
    • Vassault, A.1    Baud, M.2    Castanier, M.3
  • 9
    • 0020526697 scopus 로고
    • In vitro stability of cyclosporin a
    • J.M. Hows, J.M. Smith In vitro stability of cyclosporin A J Clin Pathol 36 1983 720
    • (1983) J Clin Pathol , vol.36 , pp. 720
    • Hows, J.M.1    Smith, J.M.2
  • 10
    • 0022894666 scopus 로고
    • Preparation and optimal storage of a whole-blood control pool for cyclosporin a
    • J.L. Rudy, J. Rutledge Preparation and optimal storage of a whole-blood control pool for cyclosporin A Clin Chem 32 1986 2204
    • (1986) Clin Chem , vol.32 , pp. 2204
    • Rudy, J.L.1    Rutledge, J.2
  • 11
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • J.M. Bland, D.G. Altman Measuring agreement in method comparison studies Stat Methods Med Res 8 1999 135
    • (1999) Stat Methods Med Res , vol.8 , pp. 135
    • Bland, J.M.1    Altman, D.G.2
  • 12
    • 0030021476 scopus 로고    scopus 로고
    • Analysis of method comparison studies
    • S. Hollis Analysis of method comparison studies Ann Clin Biochem 33 Pt. 1 1996 1
    • (1996) Ann Clin Biochem , vol.33 , Issue.1 PART , pp. 1
    • Hollis, S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.