메뉴 건너뛰기




Volumn 54, Issue 1, 2005, Pages 25-36

Performance assessment of leak detection failure sensors used in a water distribution system

Author keywords

Flushing; Leakage; Monitoring; Sensors; Water distribution systems

Indexed keywords

COMPUTER SOFTWARE; FLOW OF FLUIDS; LEAK DETECTION; OPTICAL SENSORS; PIPELINES;

EID: 16244370103     PISSN: 00037214     EISSN: None     Source Type: Journal    
DOI: 10.2166/aqua.2005.0003     Document Type: Article
Times cited : (14)

References (9)
  • 1
    • 16244392963 scopus 로고
    • Leakage Control: The Neglected Solution?
    • 22-26 August 1994, Colombo, Sri Lanka
    • Bridges, G. & MacDonald, M. 1994 Leakage Control: The Neglected Solution? Proceeding of the 20th WEDC Conference, 22-26 August 1994, Colombo, Sri Lanka, pp. 239-241.
    • (1994) Proceeding of the 20th WEDC Conference , pp. 239-241
    • Bridges, G.1    MacDonald, M.2
  • 3
    • 0001794363 scopus 로고    scopus 로고
    • Acoustical characteristics of leak signals in plastic water distribution pipes
    • Hunaidi, O. & Chu, W. 1999 Acoustical characteristics of leak signals in plastic water distribution pipes. Appl. Acoust. 58, 235-254.
    • (1999) Appl. Acoust. , vol.58 , pp. 235-254
    • Hunaidi, O.1    Chu, W.2
  • 4
    • 2042432420 scopus 로고    scopus 로고
    • Ground-Penetrating Radar for Detection of Leaks in Buried Plastic Water Distribution Pipes
    • 27-30 May 1998, Lawrence, Kansas
    • Hunaidi, O. & Giamou, P. 1998 Ground-Penetrating Radar for Detection of Leaks in Buried Plastic Water Distribution Pipes. Proceedings of the 7th International Conference on Ground Penetrating Radar, 27-30 May 1998, Lawrence, Kansas, pp. 783-786.
    • (1998) Proceedings of the 7th International Conference on Ground Penetrating Radar , pp. 783-786
    • Hunaidi, O.1    Giamou, P.2
  • 6
    • 0036204309 scopus 로고    scopus 로고
    • Low-cost failure sensor systems for water pipeline distribution systems
    • Khan, A., Widdop, P. D., Day, A. J., Wood, A. S., Mounce, S. R. & Machell, J. 2002a Low-cost failure sensor systems for water pipeline distribution systems. Wat. Sci. Technol. 45(4/5), 207-216.
    • (2002) Wat. Sci. Technol. , vol.45 , Issue.4-5 , pp. 207-216
    • Khan, A.1    Widdop, P.D.2    Day, A.J.3    Wood, A.S.4    Mounce, S.R.5    Machell, J.6
  • 7
    • 16244386741 scopus 로고    scopus 로고
    • A low-cost failure sensor based on water opacity: Performance assessment in pipeline distribution
    • submitted
    • Khan, A., Widdop, P. D., Day, A. J., Wood, A. S., Mounce, S. R. and Machell, J. 2002b A low-cost failure sensor based on water opacity: Performance assessment in pipeline distribution. Int. J. Wat. (submitted).
    • (2002) Int. J. Wat.
    • Khan, A.1    Widdop, P.D.2    Day, A.J.3    Wood, A.S.4    Mounce, S.R.5    Machell, J.6
  • 8
    • 16244370593 scopus 로고    scopus 로고
    • Measured water temperature characteristics in a pipeline distribution system
    • submitted
    • Khan, A., Widdop, P. D., Day, A. J., Wood, A. S., Mounce, S. R. and Machell, J. 2002c Measured water temperature characteristics in a pipeline distribution system. Wat. Res. (submitted).
    • (2002) Wat. Res.
    • Khan, A.1    Widdop, P.D.2    Day, A.J.3    Wood, A.S.4    Mounce, S.R.5    Machell, J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.