메뉴 건너뛰기




Volumn 1, Issue 2, 2003, Pages 119-122

Sensitivity of P. vivax rapid antigen detection tests and possible implications for self-diagnostic use

Author keywords

Diagnosis; Malaria; P. Vivax; Rapid antigen detection; Self diagnosis

Indexed keywords

ANTIGEN DETECTION; ARTICLE; CONTROLLED STUDY; DEVICE; DIAGNOSTIC ACCURACY; ENDEMIC DISEASE; FEVER; GERMANY; HUMAN; MAJOR CLINICAL STUDY; MALARIA; MICROSCOPY; PLASMODIUM VIVAX; PRIORITY JOURNAL; SELF EVALUATION; TRAVEL;

EID: 15944417466     PISSN: 14778939     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1477-8939(03)00037-1     Document Type: Article
Times cited : (11)

References (10)
  • 1
    • 0036144418 scopus 로고    scopus 로고
    • Rapid diagnostic tests for malaria parasites
    • Moody A. Rapid diagnostic tests for malaria parasites. Clin Microbiol Rev 2000;15:66-78.
    • (2000) Clin Microbiol Rev , vol.15 , pp. 66-78
    • Moody, A.1
  • 2
    • 0036274614 scopus 로고    scopus 로고
    • Comparison of three antigen detection methods for diagnosis and therapeutic monitoring of malaria: A field study from southern Vietnam
    • Huong NM, Davis TME, Hewitt S, Huong NV, Uyen TT, Nhan DH, Cong LD. Comparison of three antigen detection methods for diagnosis and therapeutic monitoring of malaria: a field study from southern Vietnam. Trop Med Int Health 2002;7:304-8.
    • (2002) Trop Med Int Health , vol.7 , pp. 304-308
    • Huong, N.M.1    Davis, T.M.E.2    Hewitt, S.3    Huong, N.V.4    Uyen, T.T.5    Nhan, D.H.6    Cong, L.D.7
  • 3
    • 0032813155 scopus 로고    scopus 로고
    • Field evaluation of the ICT Malaria P.f./P.v.® immunochromatographic test for detection of Plasmodium falciparum and Plasmodium vivax in patients with presumptive clinical diagnosis of malaria in eastern Indonesia
    • Tjitra E, Suprianto S, Dyer M, Currie BJ, Anstey NM. Field evaluation of the ICT Malaria P.f./P.v.® immunochromatographic test for detection of Plasmodium falciparum and Plasmodium vivax in patients with presumptive clinical diagnosis of malaria in eastern Indonesia. J Clin Microbiol 1999;37:2412-17.
    • (1999) J Clin Microbiol , vol.37 , pp. 2412-2417
    • Tjitra, E.1    Suprianto, S.2    Dyer, M.3    Currie, B.J.4    Anstey, N.M.5
  • 4
    • 0033866511 scopus 로고    scopus 로고
    • Performance of the OptiMal® malaria antigen capture dipstick for malaria diagnosis and treatment monitoring at the Hospital for Tropical Diseases
    • Moody A, Hunt-Cooke A, Gabbett E, Chiodini P. Performance of the OptiMal® malaria antigen capture dipstick for malaria diagnosis and treatment monitoring at the Hospital for Tropical Diseases. London Br J Haematol 2000;109:891-94.
    • (2000) London Br J Haematol , vol.109 , pp. 891-894
    • Moody, A.1    Hunt-Cooke, A.2    Gabbett, E.3    Chiodini, P.4
  • 5
    • 0037350592 scopus 로고    scopus 로고
    • Comparison of three antigen detection tests for diagnosis and follow-up of falciparum malaria in travellers returning to Berlin, Germany
    • Grobusch MP, Hänscheid T, Göebels K, Slevogt H, Zoller T, Röegler G, Teichmann D. Comparison of three antigen detection tests for diagnosis and follow-up of falciparum malaria in travellers returning to Berlin, Germany. Parasitol Res 2003;89:354-7.
    • (2003) Parasitol Res , vol.89 , pp. 354-357
    • Grobusch, M.P.1    Hänscheid, T.2    Göebels, K.3    Slevogt, H.4    Zoller, T.5    Röegler, G.6    Teichmann, D.7
  • 6
    • 0032794089 scopus 로고    scopus 로고
    • Feasibility of a rapid dipstick antigen-capture assay for self-testing of traveller's malaria
    • Trachsler M, Schlagenhauf P, Steffen R. Feasibility of a rapid dipstick antigen-capture assay for self-testing of traveller's malaria. Trop Med Int Health 1999;4:442-7.
    • (1999) Trop Med Int Health , vol.4 , pp. 442-447
    • Trachsler, M.1    Schlagenhauf, P.2    Steffen, R.3
  • 8
    • 0033530437 scopus 로고    scopus 로고
    • Self-use of rapid tests for malaria diagnosis by tourists
    • Jelinek T, Amsler L, Grobusch MP, Nothdurft HD. Self-use of rapid tests for malaria diagnosis by tourists. Lancet 1999;354:1609.
    • (1999) Lancet , vol.354 , pp. 1609
    • Jelinek, T.1    Amsler, L.2    Grobusch, M.P.3    Nothdurft, H.D.4
  • 9
    • 0034649953 scopus 로고    scopus 로고
    • Self-use of rapid tests for malaria diagnosis
    • Behrens RH, Whitty CJ. Self-use of rapid tests for malaria diagnosis. Lancet 2000;355:237.
    • (2000) Lancet , vol.355 , pp. 237
    • Behrens, R.H.1    Whitty, C.J.2
  • 10
    • 0036453621 scopus 로고    scopus 로고
    • Rapid immunochromatographic malarial antigen detection unreliable for detecting Plasmodium malariae and Plasmodium ovale
    • Grobusch MP, Hänscheid T, Zoller T, Jelinek T, Burchard GD. Rapid immunochromatographic malarial antigen detection unreliable for detecting Plasmodium malariae and Plasmodium ovale. Eur J Clin Microbiol Infect Dis 2002;21:818-20.
    • (2002) Eur J Clin Microbiol Infect Dis , vol.21 , pp. 818-820
    • Grobusch, M.P.1    Hänscheid, T.2    Zoller, T.3    Jelinek, T.4    Burchard, G.D.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.