Volumn 21, Issue 3, 2005, Pages 273-279
|
Determination of trace sodium in the water-steam system of power plants using an FIA/ISE method with an automatic penetration and alkalization apparatus
|
Author keywords
[No Author keywords available]
|
Indexed keywords
CHEMICAL REACTIONS;
FOSSIL FUEL POWER PLANTS;
ION SELECTIVE ELECTRODES;
METAL IONS;
SODIUM;
TRACE ANALYSIS;
CONCENTRATION RANGES;
FOSSIL POWER PLANTS;
HERMETICALLY SEALED;
OPTIMUM CONDITIONS;
RELATIVE STANDARD DEVIATIONS;
SAMPLING VOLUME;
SODIUM IONS;
TRACE LEVEL;
STEAM POWER PLANTS;
SODIUM;
ALKALINITY;
ALKALINIZATION;
ANALYTIC METHOD;
ARTICLE;
ELECTRIC POWER PLANT;
FLOW INJECTION ANALYSIS;
FLOW RATE;
FOSSIL;
ION SELECTIVE ELECTRODE;
REACTION ANALYSIS;
SENSITIVITY AND SPECIFICITY;
STREAM (RIVER);
TEMPERATURE;
THICKNESS;
|
EID: 15944384944
PISSN: 09106340
EISSN: None
Source Type: Journal
DOI: 10.2116/analsci.21.273 Document Type: Article |
Times cited : (14)
|