-
1
-
-
0001288436
-
The coil planet centrifuge
-
Ito, Y.; Weinstein, M.; Aoki, I.; Harada, R.; Kimura, E.; Nunogaki, K. The coil planet centrifuge. Nature 1966, 212, 985 (No. 5066).
-
(1966)
Nature
, vol.212
, Issue.5066
, pp. 985
-
-
Ito, Y.1
Weinstein, M.2
Aoki, I.3
Harada, R.4
Kimura, E.5
Nunogaki, K.6
-
2
-
-
0018791335
-
Nonsynchronous flow-through coil planet centrifuge applied to cell separation with physiological solution
-
Ito, Y.; Carmeci, P.; Sutherland, I.A. Nonsynchronous flow-through coil planet centrifuge applied to cell separation with physiological solution. Anal. Biochem. 1979, 94, 249.
-
(1979)
Anal. Biochem.
, vol.94
, pp. 249
-
-
Ito, Y.1
Carmeci, P.2
Sutherland, I.A.3
-
3
-
-
0019123922
-
Cell separation using two-phase polymer systems in a nonsynchronous flow-through coil planet centrifuge
-
Sutherland, I.A.; Ito, Y. Cell separation using two-phase polymer systems in a nonsynchronous flow-through coil planet centrifuge. Anal. Biochem. 1980, 108, 367.
-
(1980)
Anal. Biochem.
, vol.108
, pp. 367
-
-
Sutherland, I.A.1
Ito, Y.2
-
4
-
-
0018958692
-
The nonsynchronous flow-through coil planet centrifuge without rotating seals applied to cell separation
-
Ito, Y.; Carmeci, P.; Bhatnagar, R.; Leighton, S.B.; Seldon, R. The nonsynchronous flow-through coil planet centrifuge without rotating seals applied to cell separation. Sep. Sci. Technol. 1980, 15, 1589.
-
(1980)
Sep. Sci. Technol.
, vol.15
, pp. 1589
-
-
Ito, Y.1
Carmeci, P.2
Bhatnagar, R.3
Leighton, S.B.4
Seldon, R.5
-
5
-
-
0020547234
-
Improved nonsynchronous flow-through coil planet centrifuge without rotating seals: Principle and application
-
Ito, Y.; Bramblett, G.T.; Bhatnagar, R.; Huberman, M.; Leive, L.L.; Cullinane, L.M.; Groves, W. Improved nonsynchronous flow-through coil planet centrifuge without rotating seals: principle and application. Sep. Sci. Technol. 1983, 18, 33.
-
(1983)
Sep. Sci. Technol.
, vol.18
, pp. 33
-
-
Ito, Y.1
Bramblett, G.T.2
Bhatnagar, R.3
Huberman, M.4
Leive, L.L.5
Cullinane, L.M.6
Groves, W.7
-
6
-
-
0021371753
-
Countercurrent Chromatographic separation of bacteria with known differences in surface lipopolysaccharide
-
Leive, L.; Cullinane, L.M.; Ito, Y.; Bramblett, G.T. Countercurrent Chromatographic separation of bacteria with known differences in surface lipopolysaccharide. J. Liq. Chromatogr. 1984, 7, 403.
-
(1984)
J. Liq. Chromatogr.
, vol.7
, pp. 403
-
-
Leive, L.1
Cullinane, L.M.2
Ito, Y.3
Bramblett, G.T.4
-
7
-
-
0030002403
-
Purification of mast cells with an improved nonsynchronous flow-through coil planet centrifuge
-
Okada, T.; Metcalfe, D.D.; Ito, Y. Purification of mast cells with an improved nonsynchronous flow-through coil planet centrifuge. Int. Arch. Allergy Immunol. 1996, 109, 376.
-
(1996)
Int. Arch. Allergy Immunol.
, vol.109
, pp. 376
-
-
Okada, T.1
Metcalfe, D.D.2
Ito, Y.3
-
8
-
-
0038644056
-
-
Shinomiya, K.; Kabasawa, Y.; Yanagidaira, K.; Sasaki, H.; Muto, M.; Okada, T.; Ito, Y.J. Chromatogr. A B 1005, 103.
-
Chromatogr. A B
, vol.1005
, pp. 103
-
-
Shinomiya, K.1
Kabasawa, Y.2
Yanagidaira, K.3
Sasaki, H.4
Muto, M.5
Okada, T.6
Ito, Y.J.7
-
9
-
-
8844219710
-
Effect of the planetary motion of a coiled column on protein separation by the nonsynchronous coil planet centrifuge
-
Shinomiya, K.; Ito, Y. Effect of the planetary motion of a coiled column on protein separation by the nonsynchronous coil planet centrifuge. J. Liq. Chrom. & Rel. Technol. 2004, 27 (20), 1.
-
(2004)
J. Liq. Chrom. & Rel. Technol.
, vol.27
, Issue.20
, pp. 1
-
-
Shinomiya, K.1
Ito, Y.2
-
10
-
-
0015883441
-
Basophils in bronchial asthma with reference to regain-type allergy
-
Kimura, I.; Moritani, Y.; Tanizaki, Y. Basophils in bronchial asthma with reference to regain-type allergy. Clin. Allergy 1973, 3, 195.
-
(1973)
Clin. Allergy
, vol.3
, pp. 195
-
-
Kimura, I.1
Moritani, Y.2
Tanizaki, Y.3
|