메뉴 건너뛰기




Volumn 5535, Issue , 2004, Pages 77-88

CT perfusion: Principles, applications and problems

Author keywords

Arterial delay; Arterial dispersion; CBF and CBV mismatch; Central Volume Principle; CT perfusion; Deconvolution; Ischemic penumbra; Partial volume averaging

Indexed keywords

BLOOD; BRAIN; CONCENTRATION (PROCESS); CONVOLUTION; HEMODYNAMICS; IMAGE PROCESSING; IMAGING TECHNIQUES; NATURAL FREQUENCIES; TISSUE;

EID: 15844427257     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.561039     Document Type: Conference Paper
Times cited : (4)

References (12)
  • 3
    • 0036200242 scopus 로고    scopus 로고
    • Prognostic accuracy of cerebral blood flow measurement by perfusion computed tomography, at the time of emergency room admission, in acute stroke patients
    • Wintermark M, Reichhart M, Thiran JP, Maeder P, Chalaron M, Schnyder P, Bogousslavsky J, Meuli R. Prognostic accuracy of cerebral blood flow measurement by perfusion computed tomography, at the time of emergency room admission, in acute stroke patients. Ann Neurol. 51(4):417-32, 2002.
    • (2002) Ann Neurol. , vol.51 , Issue.4 , pp. 417-432
    • Wintermark, M.1    Reichhart, M.2    Thiran, J.P.3    Maeder, P.4    Chalaron, M.5    Schnyder, P.6    Bogousslavsky, J.7    Meuli, R.8
  • 5
    • 77049181625 scopus 로고
    • On the theory of the indicatordilution method for measurement of blood flow and volume
    • Meier P, Zierler KL. On the theory of the indicatordilution method for measurement of blood flow and volume. J.Appl.Physiol 6:731-744, 1954.
    • (1954) J.Appl.Physiol , vol.6 , pp. 731-744
    • Meier, P.1    Zierler, K.L.2
  • 6
    • 0029907308 scopus 로고    scopus 로고
    • High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysis
    • Østergaard L, Weisskoff RM, Chesler DA, Gyldensted C, Rosen BR. High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: mathematical approach and statistical analysis. Magn Reson Med 36:715-725, 1996.
    • (1996) Magn Reson Med , vol.36 , pp. 715-725
    • Østergaard, L.1    Weisskoff, R.M.2    Chesler, D.A.3    Gyldensted, C.4    Rosen, B.R.5
  • 9
    • 0027982679 scopus 로고
    • Viability thresholds and the penumbra of focal ischemia
    • Hossmann KA. Viability thresholds and the penumbra of focal ischemia. Ann Neurol. 3:557-65, 1994.
    • (1994) Ann Neurol. , vol.3 , pp. 557-565
    • Hossmann, K.A.1
  • 10
    • 15844405417 scopus 로고    scopus 로고
    • Defining the ischemic penumbra and core using cerebral blood flow and cerebral blood volume
    • June Vancouver, Canada
    • th World Stroke Congress, June 2004, Vancouver, Canada.
    • (2004) th World Stroke Congress
    • Murphy, B.D.1    Lee, T.-Y.2
  • 11
    • 0037587219 scopus 로고    scopus 로고
    • Tracer arrival timing-insensitive technique for estimating flow in MR perfusion-weighted imaging using singular value decomposition with a block-circulant deconvolution matrix
    • Wu O, Østergaard L, Weisskoff RM, Benner T, Rosen BR, Sorensen AG. Tracer Arrival Timing-Insensitive Technique for Estimating Flow in MR Perfusion-Weighted Imaging Using Singular Value Decomposition With a Block-Circulant Deconvolution Matrix. Magnetic Resonance in Medicine 50:164-174, 2003.
    • (2003) Magnetic Resonance in Medicine , vol.50 , pp. 164-174
    • Wu, O.1    Østergaard, L.2    Weisskoff, R.M.3    Benner, T.4    Rosen, B.R.5    Sorensen, A.G.6
  • 12
    • 0042739012 scopus 로고    scopus 로고
    • Estimation of bolus dispersion effects in perfusion MRI using image-based computational fluid dynamics
    • Calamante F, Yim PJ, Cebral JR. Estimation of bolus dispersion effects in perfusion MRI using image-based computational fluid dynamics. Neuroimage 19:341-53, 2003.
    • (2003) Neuroimage , vol.19 , pp. 341-353
    • Calamante, F.1    Yim, P.J.2    Cebral, J.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.